Skip to main content
ENERGY STAR water heater model · PD 3554176

Richmond 10E40-HP5US30 Water Heater Specifications (3.83 UEF)

Certified at 3.83 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Richmond 10E40-HP5US30 (Hybrid/Electric Heat Pump, Electric) places #230 of 706 out of 706 ENERGY STAR models (PD 3554176). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Uniform Energy Factor
3.83 UEF
Cohort UEF Rank
#230 of 706 (top 37.8%)
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.53 / +66.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10E40-HP5US30 at 3.83 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10E40-HP5US30: 3.83
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10E40-HP5US30 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.83 UEF, Richmond 10E40-HP5US30 places #230 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.13 UEF vs. 3.70 UEF median).

Richmond 10E40-HP5US30 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Richmond 10E40-HP5US30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10E40-HP5US30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Richmond 10E40-HP5US30 include Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) alongside Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity).

How Complete Are the Certified Metrics for Richmond 10E40-HP5US30?

Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Richmond 10E40-HP5US30 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3554176
Model Number10E40-HP5US30Draw pattern: Medium-Usage10E40-HP5US30
Uniform Energy Factor (UEF)3.83+0.13 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use859 kWh/yr-213 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency434%+5.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Is the Projected Utility Bill for 10E40-HP5US30 by State?

At 859 kWh/yr, Richmond 10E40-HP5US30 averages about $156/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (859 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$405.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,560 $4,934
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $405/yr $4,053 $12,819
California 29.75 ¢/kWh ($0.2975) $256/yr $2,556 $8,083
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,367 $4,323
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,257 $3,975
Estimated electricity spend (859 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Richmond Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Richmond in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to 10E40-HP5US30?

Ordered by minimal capacity and UEF spread relative to Richmond 10E40-HP5US30, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Rheem CPROPH40 T2 RH400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Ruud CPROPH40 T2 CD375-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (-0.23) 902
Friedrich PROH40 T2 FD400-SO Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859

What Installation Caveats Apply Before Buying Richmond 10E40-HP5US30?

Even high-UEF units like Richmond 10E40-HP5US30 (3.83 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Richmond 10E40-HP5US30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10E40-HP5US30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10E40-HP5US30 Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

Practical Specs & Code Questions for Richmond 10E40-HP5US30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Richmond 10E40-HP5US30 eligible for continued manufacture past May 6, 2029?

At 3.83 UEF, Richmond 10E40-HP5US30 achieves Pass: +1.53 / +66.5% for the 2029 DOE standard and stands #230 of 706 (top 37.8%) against Friedrich PROH40 T2 FD400-30 and Rheem CPROPH40 T2 RH400-30.

How tall and wide is Richmond 10E40-HP5US30, and what service clearance is needed?

Physical dimensions for Richmond 10E40-HP5US30 are 62.3 in. height and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)); verify stair turns and drain pan width before delivery.

Will Richmond 10E40-HP5US30 require upgrading household electrical panels or gas piping?

Richmond 10E40-HP5US30 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Richmond 10E40-HP5US30 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $156/yr ($1,560 over 10 years) to power Richmond 10E40-HP5US30 at 859 kWh/yr under the 18.16 cents/kWh US average (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

Which installation bottlenecks limit Richmond 10E40-HP5US30?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Richmond 10E40-HP5US30 drops into resistance mode more often.

How does Richmond 10E40-HP5US30 handle simultaneous showers and laundry?

Delivering 60 gal in the first hour (-12 gal vs. 72 gal median), Richmond 10E40-HP5US30 combines 36 gal tank storage with rapid burner/element recovery.

How long is the warranty on Richmond 10E40-HP5US30 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 10E40-HP5US30 before calling service.

How do 2026 post-OBBBA rebates affect buying Richmond 10E40-HP5US30?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks