Richmond 10E80-HP5UZ30 Water Heater Specifications (4.07 UEF)
The Richmond 10E80-HP5UZ30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, ranking #26 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4692175). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.57 / +62.8%. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).
- Uniform Energy Factor
- 4.07 UEF
- Cohort UEF Rank
- #26 of 706 (top 8.5%)
- First Hour Rating
- 87 gal
- Storage Volume
- 72 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.57 / +62.8%

Richmond 10E80-HP5UZ30 (4.07 UEF) ranks #26 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 8.5%, more efficient than 91.5% of Hybrid/Electric Heat Pump models, +0.37 UEF above the 3.70 UEF median.
Federal 2029 margin for Richmond 10E80-HP5UZ30: +1.57 UEF (+62.8%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Richmond 10E80-HP5UZ30 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10E80-HP5UZ30: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Richmond 10E80-HP5UZ30 (4.07 UEF) compares closely with Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Rheem CPROPH80 T2 RH375-SO (4.07 UEF, at parity).
Where Does Richmond 10E80-HP5UZ30 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10E80-HP5UZ30 holds #26 of 706 (top 8.5%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 4692175 |
| Model Number | 10E80-HP5UZ30 | Draw pattern: High-Usage | 10E80-HP5UZ30 |
| Uniform Energy Factor (UEF) | 4.07 | +0.37 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 447% | +18.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |
How Much Electricity Does 10E80-HP5UZ30 Use in Different States?
Estimated at $220/yr nationally (1,213 kWh/yr), 10-year utility spending for Richmond 10E80-HP5UZ30 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,542 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,594 |
| California | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,355 |
| Texas | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,607 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,076 |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10E80-HP5UZ30?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10E80-HP5UZ30's gallon capacity and 4.07 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH80 T2 FD400-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Rheem CPROPH80 T2 RH375-SO | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| Ruud CPROPH80 T2 CD375-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| LG APHWC802D | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (+0.03) | 1,210 |
| Friedrich PROH80 T2 FD400-SO | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
Who Is Richmond 10E80-HP5UZ30 Best For — and When Should You Pick Friedrich PROH80 T2 FD400-30?
Evaluate whether Richmond 10E80-HP5UZ30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Richmond 10E80-HP5UZ30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10E80-HP5UZ30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 10E80-HP5UZ30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Richmond 10E80-HP5UZ30 (4.07 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Richmond 10E80-HP5UZ30 records 4.07 UEF (Pass: +1.57 / +62.8%), placing #26 of 706 (top 8.5%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Richmond 10E80-HP5UZ30 fit inside a tight hallway closet or low-headroom utility room?
Richmond 10E80-HP5UZ30 requires room for its 74.2 in. vertical shell and 24.3 in. diameter (needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Richmond 10E80-HP5UZ30?
For Richmond 10E80-HP5UZ30, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Richmond 10E80-HP5UZ30?
Using 1,213 kWh/yr, Richmond 10E80-HP5UZ30 generates an estimated $220/yr electric bill at 18.16 cents/kWh (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Richmond 10E80-HP5UZ30 (4.07 UEF)?
Richmond 10E80-HP5UZ30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH80 T2 FD400-30.
What hot-water delivery rating governs Richmond 10E80-HP5UZ30?
Rated for 87 gal FHR (+15 gal vs. 72 gal median), Richmond 10E80-HP5UZ30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Richmond 10E80-HP5UZ30 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Richmond; use our browser-only serial decoder to inspect Richmond 10E80-HP5UZ30's age and warranty window.
What alternative models sit closest to Richmond 10E80-HP5UZ30 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)