ENERGY STAR water heater model · PD 3387616

Richmond 9GUH40-50FN Water Heater Specifications (0.9 UEF)

Certified at 0.9 UEF across its 40-gallon nominal tank, 88 gal First Hour Rating, Richmond 9GUH40-50FN (Gas Storage, Natural Gas) places #1 of 71 out of 71 ENERGY STAR models (PD 3387616). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
88 gal
Storage Volume
40 gal
Fuel / Type
Natural Gas / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking Richmond 9GUH40-50FN at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58Richmond 9GUH40-50FN: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 9GUH40-50FN relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.9 UEF, Richmond 9GUH40-50FN places #1 of 71 across 71 certified Gas Storage configurations (At 0.90 UEF median).

Richmond 9guh40-50fn stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Closest alternatives to Richmond 9GUH40-50FN include Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF, at parity) alongside Rheem ECE G40-50U CN HE* (0.9 UEF, at parity).

How Do Richmond 9GUH40-50FN Specs Compare to Gas Storage Medians?

Richmond 9GUH40-50FN places #1 of 71 across 71 certified Gas Storage configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3387616
Model Number9GUH40-50FNDraw pattern: High-Usage9GUH40-50FN
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)88 gal-7 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)54.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Richmond Water Heaters?

Zero active CPSC recalls matched Richmond in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match 9GUH40-50FN Most Closely?

These 5 competing Gas Storage units sit nearest to Richmond 9GUH40-50FN by storage capacity and 0.9 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 40-50P FD HE EC3 Gas Storage 40 gal 88 gal 0.9 (at parity) —
Rheem ECE G40-50U CN HE* Gas Storage 40 gal 88 gal 0.9 (at parity) —
Ruud PRO+G40-50P RU HE EC1 Gas Storage 40 gal 88 gal 0.9 (at parity) —
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Friedrich 12PROG 40-50U FD HE EC3 Gas Storage 40 gal 88 gal 0.9 (at parity) —

What Installation Caveats Apply Before Buying Richmond 9GUH40-50FN?

Even high-UEF units like Richmond 9GUH40-50FN (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Richmond 9GUH40-50FN logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Richmond 9GUH40-50FN's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Richmond 9GUH40-50FN Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 40-50P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About Richmond 9GUH40-50FN?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Richmond 9GUH40-50FN eligible for continued manufacture past May 6, 2029?

At 0.9 UEF, Richmond 9GUH40-50FN achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #1 of 71 against Friedrich 12PROG 40-50P FD HE EC3 and Rheem ECE G40-50U CN HE*.

How tall and wide is Richmond 9GUH40-50FN, and what service clearance is needed?

Physical dimensions for Richmond 9GUH40-50FN are 54.5 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

Will Richmond 9GUH40-50FN require upgrading household electrical panels or gas piping?

Check Natural Gas piping and venting for Richmond 9GUH40-50FN (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is Richmond 9GUH40-50FN economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Richmond 9GUH40-50FN (Natural Gas, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with Friedrich 12PROG 40-50P FD HE EC3.

Which installation bottlenecks limit Richmond 9GUH40-50FN?

Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing Richmond 9GUH40-50FN over Friedrich 12PROG 40-50P FD HE EC3.

How does Richmond 9GUH40-50FN handle simultaneous showers and laundry?

Delivering 88 gal in the first hour (-7 gal vs. 95 gal median), Richmond 9GUH40-50FN combines 40 gal tank storage with rapid burner/element recovery.

How long is the warranty on Richmond 9GUH40-50FN and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 9GUH40-50FN before calling service.

How do 2026 post-OBBBA rebates affect buying Richmond 9GUH40-50FN?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Storage is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks