Skip to main content
ENERGY STAR water heater model · PD 3387972

Richmond 9GUH40-50FP Water Heater Specifications (0.9 UEF)

Engineered as a Propane Gas Storage unit, Richmond 9GUH40-50FP achieves a certified 0.9 UEF rating across its 40-gallon nominal tank, 88 gal First Hour Rating and ranks #1 of 71 in its 71-model cohort (PD 3387972), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
88 gal
Storage Volume
40 gal
Fuel / Type
Propane / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking Richmond 9GUH40-50FP at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58Richmond 9GUH40-50FP: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 9GUH40-50FP relative to the cohort median.
Efficiency comparison & rule summary

Within the 71-unit Gas Storage cohort, Richmond 9GUH40-50FP logs 0.9 UEF and ranks #1 of 71.

Richmond 9guh40-50fp stores 40 gal nominal; 88 gal first hour rating (-7 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d).

Cross-shopping Richmond 9GUH40-50FP (0.9 UEF)? Check Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF, at parity) and Rheem ECE G40-50U CN HE* (0.9 UEF, at parity).

Where Does Richmond 9GUH40-50FP Rank Against Peer Gas Storage Units?

Audited against 71 ENERGY STAR Gas Storage listings, Richmond 9GUH40-50FP holds #1 of 71; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3387972
Model Number9GUH40-50FPDraw pattern: High-Usage9GUH40-50FP
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)88 gal-7 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)54.5" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States

Does CPSC Flag Any Safety Notices on Richmond Units?

No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Storage Models Compare Closest to 9GUH40-50FP?

Compare five nearby ENERGY STAR Gas Storage options matched closely to Richmond 9GUH40-50FP's gallon capacity and 0.9 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 40-50P FD HE EC3 Gas Storage 40 gal 88 gal 0.9 (at parity) —
Rheem ECE G40-50U CN HE* Gas Storage 40 gal 88 gal 0.9 (at parity) —
Ruud PRO+G40-50P RU HE EC1 Gas Storage 40 gal 88 gal 0.9 (at parity) —
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Friedrich 12PROG 40-50U FD HE EC3 Gas Storage 40 gal 88 gal 0.9 (at parity) —

What Are the Limitations of Richmond 9GUH40-50FP and Who Should Not Install It?

Before ordering Richmond 9GUH40-50FP (Gas Storage, 0.9 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Richmond 9GUH40-50FP logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Richmond 9GUH40-50FP's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 88 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Richmond 9GUH40-50FP Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 40-50P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Common Homeowner Questions for Richmond 9GUH40-50FP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond 9GUH40-50FP pass the May 6, 2029 federal DOE efficiency rule?

Richmond 9GUH40-50FP carries a verified 0.9 UEF rating (Pass: +0.32 / +55.2%), ranking #1 of 71 across 71 ENERGY STAR Gas Storage models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond 9GUH40-50FP need?

Richmond 9GUH40-50FP stands 54.5 in. high with a 21.8 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Richmond 9GUH40-50FP require?

Richmond 9GUH40-50FP runs on Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Richmond 9GUH40-50FP cost per year to run?

ENERGY STAR rates Richmond 9GUH40-50FP as a Propane heater (0.9 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Storage draw.

Who should NOT install Richmond 9GUH40-50FP, and what are its limits?

Richmond 9GUH40-50FP (0.9 UEF) is not suited for multi-bath marathon draws exceeding its 88 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

How many bathrooms or people can Richmond 9GUH40-50FP serve at peak demand?

Richmond 9GUH40-50FP achieves a 88 gal First Hour Rating (-7 gal vs. 95 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for Richmond 9GUH40-50FP?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond 9GUH40-50FP because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond 9GUH40-50FP, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Storage is Friedrich 12PROG 40-50P FD HE EC3 (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks