Skip to main content
ENERGY STAR water heater model · PD 2408523

Ruud PRO H80 T2 RU310UM Water Heater Specifications (3.5 UEF)

With PD 2408523 certification, Ruud PRO H80 T2 RU310UM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.00 / +40.0% for May 6, 2029. Rated annual electricity draw of 1,303 kWh/yr equates to roughly $237/yr ($2,366 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD310BM (3.5 UEF).

Uniform Energy Factor
3.5 UEF
Cohort UEF Rank
#481 of 706
First Hour Rating
87 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.00 / +40.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PRO H80 T2 RU310UM at 3.5 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Ruud PRO H80 T2 RU310UM: 3.50
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PRO H80 T2 RU310UM relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Ruud PRO H80 T2 RU310UM at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Ruud PRO H80 T2 RU310UM stands +1.00 UEF (+40.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,303 kWh/yr for Ruud PRO H80 T2 RU310UM runs ~$237/yr vs. ~$900/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PRO H80 T2 RU310UM: 10-year operating spend spans $1,906 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,148 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH80 T2 FD310BM (3.5 UEF, at parity) and Rheem CPROPH80 T2 RH350BM (3.5 UEF, at parity) bracket Ruud PRO H80 T2 RU310UM.

How Complete Are the Certified Metrics for Ruud PRO H80 T2 RU310UM?

Standing at #481 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Ruud PRO H80 T2 RU310UM brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 2408523
Model NumberPRO H80 T2 RU310UMDraw pattern: High-UsagePRO H80 T2 RU310UM
Uniform Energy Factor (UEF)3.5-0.20 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,303 kWh/yr+231 kWh/yr vs. 1,072 kWh/yr medianEst. $237/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency398%-31.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)74.2" H x 24.3" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Is the Projected Utility Bill for PRO H80 T2 RU310UM by State?

At 1,303 kWh/yr, Ruud PRO H80 T2 RU310UM averages about $237/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,303 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$237.00/yrHawaii$615.00/yrCalifornia$388.00/yrTexas$207.00/yrWashington$191.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $237/yr $2,366 $6,636
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $615/yr $6,148 $17,240
California 29.75 ¢/kWh ($0.2975) $388/yr $3,876 $10,871
Texas 15.91 ¢/kWh ($0.1591) $207/yr $2,073 $5,814
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $191/yr $1,906 $5,346
Estimated electricity spend (1,303 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Ruud Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for Ruud and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which 5 Models Offer Similar Output to PRO H80 T2 RU310UM?

Ordered by minimal capacity and UEF spread relative to Ruud PRO H80 T2 RU310UM, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD310BM Hybrid/Electric Heat Pump 72 gal 87 gal 3.5 (at parity) 1,303
Rheem CPROPH80 T2 RH350BM Hybrid/Electric Heat Pump 72 gal 87 gal 3.5 (at parity) 1,303
Richmond 10E80-HP120M Hybrid/Electric Heat Pump 72 gal 84 gal 3.46 (-0.04) 1,403
LG APHWC801D Hybrid/Electric Heat Pump 72 gal 94 gal 3.9 (+0.40) 1,272
Friedrich PROH80 T2 FD310UM Hybrid/Electric Heat Pump 72 gal 87 gal 3.5 (at parity) 1,303

When Should Homeowners Skip Ruud PRO H80 T2 RU310UM (Hybrid/Electric Heat Pump)?

Check Ruud PRO H80 T2 RU310UM's mechanical constraints—including utility space, Electric capacity, and Pass: +1.00 / +40.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Ruud PRO H80 T2 RU310UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PRO H80 T2 RU310UM directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PRO H80 T2 RU310UM Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD310BM footprint.

Practical Specs & Code Questions for Ruud PRO H80 T2 RU310UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Ruud PRO H80 T2 RU310UM stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.5 UEF, Ruud PRO H80 T2 RU310UM shows Pass: +1.00 / +40.0% relative to May 6, 2029 federal DOE limits while placing #481 of 706 among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD310BM.

Will Ruud PRO H80 T2 RU310UM fit through a standard utility door and 72-inch basement ceiling?

Measuring 74.2 in. tall by 24.3 in. diameter, Ruud PRO H80 T2 RU310UM notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Ruud PRO H80 T2 RU310UM during replacement?

Electrical specs for Ruud PRO H80 T2 RU310UM call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Ruud PRO H80 T2 RU310UM?

At 18.16 cents/kWh national residential pricing, Ruud PRO H80 T2 RU310UM's 1,303 kWh/yr draw equals roughly $237 annually or $2,370 across a 10-year horizon (ranging from $191/yr in Washington hydro tiers up to $615/yr in Hawaii).

When is Ruud PRO H80 T2 RU310UM a poor fit for a residential replacement?

Avoid placing Ruud PRO H80 T2 RU310UM directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Ruud PRO H80 T2 RU310UM deliver?

With 87 gal FHR (+15 gal vs. 72 gal median), Ruud PRO H80 T2 RU310UM fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Ruud PRO H80 T2 RU310UM?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Ruud PRO H80 T2 RU310UM qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud PRO H80 T2 RU310UM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD310BM (3.5 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks