Ruud PROUH40 T2 RU400-30 Water Heater Specifications (3.83 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Ruud PROUH40 T2 RU400-30 (Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating (rank #230 of 706, PD 3554179) and verifies as Pass: +1.53 / +66.5% for 2029 DOE floors. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Uniform Energy Factor
3.83 UEF
Cohort UEF Rank
#230 of 706 (top 37.8%)
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.53 / +66.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH40 T2 RU400-30 at 3.83 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Ruud PROUH40 T2 RU400-30: 3.83
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH40 T2 RU400-30 relative to the cohort median.
Efficiency comparison & rule summary

Ruud PROUH40 T2 RU400-30 records 3.83 UEF efficiency, putting it #230 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Ruud PROUH40 T2 RU400-30 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5%). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Ruud PROUH40 T2 RU400-30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH40 T2 RU400-30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Ruud PROUH40 T2 RU400-30 (3.83 UEF) are Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity).

How Complete Are the Certified Metrics for Ruud PROUH40 T2 RU400-30?

Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Ruud PROUH40 T2 RU400-30 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 3554179
Model NumberPROUH40 T2 RU400-30Draw pattern: Medium-UsagePROUH40 T2 RU400-30
Uniform Energy Factor (UEF)3.83+0.13 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use859 kWh/yr-213 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency434%+5.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Is the Projected Utility Bill for PROUH40 T2 RU400-30 by State?

At 859 kWh/yr, Ruud PROUH40 T2 RU400-30 averages about $156/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (859 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$405.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,560 $4,934
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $405/yr $4,053 $12,819
California 29.75 ¢/kWh ($0.2975) $256/yr $2,556 $8,083
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,367 $4,323
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,257 $3,975
Estimated electricity spend (859 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Ruud Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for Ruud and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which 5 Models Offer Similar Output to PROUH40 T2 RU400-30?

Ordered by minimal capacity and UEF spread relative to Ruud PROUH40 T2 RU400-30, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Rheem CPROPH40 T2 RH400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Richmond 10CE40-HP5U30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (-0.23) 902
Friedrich PROH40 T2 FD400-SO Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859

When Should Homeowners Skip Ruud PROUH40 T2 RU400-30 (Hybrid/Electric Heat Pump)?

Check Ruud PROUH40 T2 RU400-30's mechanical constraints—including utility space, Electric capacity, and Pass: +1.53 / +66.5% status—against typical residential installations.

Key Limitations & Exclusions

  • Ruud PROUH40 T2 RU400-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH40 T2 RU400-30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH40 T2 RU400-30 Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

Practical Specs & Code Questions for Ruud PROUH40 T2 RU400-30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Ruud PROUH40 T2 RU400-30 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.83 UEF, Ruud PROUH40 T2 RU400-30 shows Pass: +1.53 / +66.5% relative to May 6, 2029 federal DOE limits while placing #230 of 706 (top 37.8%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH40 T2 FD400-30.

Will Ruud PROUH40 T2 RU400-30 fit through a standard utility door and 72-inch basement ceiling?

Measuring 62.3 in. tall by 20.3 in. diameter, Ruud PROUH40 T2 RU400-30 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Ruud PROUH40 T2 RU400-30 during replacement?

Electrical specs for Ruud PROUH40 T2 RU400-30 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Ruud PROUH40 T2 RU400-30?

At 18.16 cents/kWh national residential pricing, Ruud PROUH40 T2 RU400-30's 859 kWh/yr draw equals roughly $156 annually or $1,560 across a 10-year horizon (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

When is Ruud PROUH40 T2 RU400-30 a poor fit for a residential replacement?

Avoid placing Ruud PROUH40 T2 RU400-30 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Ruud PROUH40 T2 RU400-30 deliver?

With 60 gal FHR (-12 gal vs. 72 gal median), Ruud PROUH40 T2 RU400-30 fits 1–3 person or moderate-draw homes cleanly.

How do you verify manufacturing age and recall status on Ruud PROUH40 T2 RU400-30?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Ruud PROUH40 T2 RU400-30 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Ruud PROUH40 T2 RU400-30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)