ENERGY STAR water heater model · PD 3554181

Ruud PROUH40 T2 RU400-SO Water Heater Specifications (3.83 UEF)

Certified at 3.83 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Ruud PROUH40 T2 RU400-SO (Hybrid/Electric Heat Pump, Electric) places #230 of 706 out of 706 ENERGY STAR models (PD 3554181). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Uniform Energy Factor
3.83 UEF
Cohort UEF Rank
#230 of 706 (top 37.8%)
First Hour Rating
60 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.53 / +66.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ruud PROUH40 T2 RU400-SO at 3.83 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Ruud PROUH40 T2 RU400-SO: 3.83
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ruud PROUH40 T2 RU400-SO relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.83 UEF, Ruud PROUH40 T2 RU400-SO places #230 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.13 UEF vs. 3.70 UEF median).

Ruud PROUH40 T2 RU400-SO clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Ruud PROUH40 T2 RU400-SO runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ruud PROUH40 T2 RU400-SO: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Ruud PROUH40 T2 RU400-SO include Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) alongside Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity).

How Do Ruud PROUH40 T2 RU400-SO Specs Compare to Hybrid/Electric Heat Pump Medians?

Ruud PROUH40 T2 RU400-SO places #230 of 706 (top 37.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRuud95 certified listingsENERGY STAR PD 3554181
Model NumberPROUH40 T2 RU400-SODraw pattern: Medium-UsagePROUH40 T2 RU400-SO
Uniform Energy Factor (UEF)3.83+0.13 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)60 gal-12 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use859 kWh/yr-213 kWh/yr vs. 1,072 kWh/yr medianEst. $156/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency434%+5.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.3" H x 20.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does PROUH40 T2 RU400-SO Cost to Operate Across State Electricity Rates?

At 859 kWh/yr, Ruud PROUH40 T2 RU400-SO runs roughly $156/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (859 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$156.00/yrHawaii$405.00/yrCalifornia$256.00/yrTexas$137.00/yrWashington$126.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $156/yr $1,560 $4,934
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $405/yr $4,053 $12,819
California 29.75 ¢/kWh ($0.2975) $256/yr $2,556 $8,083
Texas 15.91 ¢/kWh ($0.1591) $137/yr $1,367 $4,323
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $126/yr $1,257 $3,975
Estimated electricity spend (859 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Ruud Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Ruud; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which Certified Water Heaters Match PROUH40 T2 RU400-SO Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ruud PROUH40 T2 RU400-SO by storage capacity and 3.83 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH40 T2 FD400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Rheem CPROPH40 T2 RH400-30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
Richmond 10CE40-HP5U30 Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (-0.23) 902
Friedrich PROH40 T2 FD400-SO Hybrid/Electric Heat Pump 36 gal 60 gal 3.83 (at parity) 859

Which Home Setups Are NOT a Fit for Ruud PROUH40 T2 RU400-SO?

Comparing Ruud PROUH40 T2 RU400-SO against Friedrich PROH40 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Ruud PROUH40 T2 RU400-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ruud PROUH40 T2 RU400-SO directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ruud PROUH40 T2 RU400-SO Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

What Are the Key Questions About Ruud PROUH40 T2 RU400-SO?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Ruud PROUH40 T2 RU400-SO score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Ruud PROUH40 T2 RU400-SO logs 3.83 UEF (Pass: +1.53 / +66.5%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Ruud PROUH40 T2 RU400-SO?

With a 62.3 in. height and 20.3 in. diameter, Ruud PROUH40 T2 RU400-SO fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Ruud PROUH40 T2 RU400-SO?

Powered via 240V at 21A max, Ruud PROUH40 T2 RU400-SO requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Ruud PROUH40 T2 RU400-SO?

Annual electric spend for Ruud PROUH40 T2 RU400-SO (859 kWh/yr) averages $156/yr nationwide (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Ruud PROUH40 T2 RU400-SO?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Ruud PROUH40 T2 RU400-SO.

Is Ruud PROUH40 T2 RU400-SO sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Ruud PROUH40 T2 RU400-SO at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Ruud have active CPSC SaferProducts notices affecting PROUH40 T2 RU400-SO?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Ruud PROUH40 T2 RU400-SO (3.83 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Ruud PROUH40 T2 RU400-SO. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks