Ruud PROUH40 T2 RU400-SO Water Heater Specifications (3.83 UEF)
Certified at 3.83 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Ruud PROUH40 T2 RU400-SO (Hybrid/Electric Heat Pump, Electric) places #230 of 706 out of 706 ENERGY STAR models (PD 3554181). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).
- Uniform Energy Factor
- 3.83 UEF
- Cohort UEF Rank
- #230 of 706 (top 37.8%)
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.53 / +66.5%

Tested at 3.83 UEF, Ruud PROUH40 T2 RU400-SO places #230 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.13 UEF vs. 3.70 UEF median).
Ruud PROUH40 T2 RU400-SO clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Ruud PROUH40 T2 RU400-SO runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ruud PROUH40 T2 RU400-SO: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Ruud PROUH40 T2 RU400-SO include Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) alongside Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity).
How Do Ruud PROUH40 T2 RU400-SO Specs Compare to Hybrid/Electric Heat Pump Medians?
Ruud PROUH40 T2 RU400-SO places #230 of 706 (top 37.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ruud | 95 certified listings | ENERGY STAR PD 3554181 |
| Model Number | PROUH40 T2 RU400-SO | Draw pattern: Medium-Usage | PROUH40 T2 RU400-SO |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Does PROUH40 T2 RU400-SO Cost to Operate Across State Electricity Rates?
At 859 kWh/yr, Ruud PROUH40 T2 RU400-SO runs roughly $156/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| California | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| Texas | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |
Are There Active CPSC Safety Recalls for Ruud Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with Ruud; match your serial plate before repair. See Serial Number Lookup.
- Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
Which Certified Water Heaters Match PROUH40 T2 RU400-SO Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to Ruud PROUH40 T2 RU400-SO by storage capacity and 3.83 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH40 T2 FD400-30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| Rheem CPROPH40 T2 RH400-30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| Richmond 10CE40-HP5U30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| Friedrich PROH40 T2 FD400-SO | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
Which Home Setups Are NOT a Fit for Ruud PROUH40 T2 RU400-SO?
Comparing Ruud PROUH40 T2 RU400-SO against Friedrich PROH40 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Ruud PROUH40 T2 RU400-SO needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ruud PROUH40 T2 RU400-SO directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About Ruud PROUH40 T2 RU400-SO?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Ruud PROUH40 T2 RU400-SO score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Ruud PROUH40 T2 RU400-SO logs 3.83 UEF (Pass: +1.53 / +66.5%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Ruud PROUH40 T2 RU400-SO?
With a 62.3 in. height and 20.3 in. diameter, Ruud PROUH40 T2 RU400-SO fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Ruud PROUH40 T2 RU400-SO?
Powered via 240V at 21A max, Ruud PROUH40 T2 RU400-SO requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Ruud PROUH40 T2 RU400-SO?
Annual electric spend for Ruud PROUH40 T2 RU400-SO (859 kWh/yr) averages $156/yr nationwide (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Ruud PROUH40 T2 RU400-SO?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Ruud PROUH40 T2 RU400-SO.
Is Ruud PROUH40 T2 RU400-SO sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Ruud PROUH40 T2 RU400-SO at 60 gal First Hour Rating (-12 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Ruud have active CPSC SaferProducts notices affecting PROUH40 T2 RU400-SO?
CPSC SaferProducts records show 2 brand-level recall notices mentioning Ruud as of 2026-11-23, including #07108 (2007-02-21). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Ruud PROUH40 T2 RU400-SO (3.83 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Ruud PROUH40 T2 RU400-SO. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)