Skip to main content
ENERGY STAR water heater model · PD 3417481

State HPAX-40-DHPT 2** Water Heater Specifications (3.6 UEF)

Certified at 3.6 UEF across its 36-gallon nominal tank, 55 gal First Hour Rating, State HPAX-40-DHPT 2** (Hybrid/Electric Heat Pump, Electric) places #401 of 706 out of 706 ENERGY STAR models (PD 3417481). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.30 / +56.5%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-40 2** (3.6 UEF).

Uniform Energy Factor
3.6 UEF
Cohort UEF Rank
#401 of 706
First Hour Rating
55 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +56.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HPAX-40-DHPT 2** at 3.6 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30State HPAX-40-DHPT 2**: 3.60
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPAX-40-DHPT 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.6 UEF, State HPAX-40-DHPT 2** places #401 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.10 UEF vs. 3.70 UEF median).

State HPAX-40-DHPT 2** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.30 UEF (+56.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for State HPAX-40-DHPT 2** runs ~$164/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPAX-40-DHPT 2**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to State HPAX-40-DHPT 2** include A. O. Smith CAHP-40 2** (3.6 UEF, at parity) alongside American HPA10240H045DV 2** (3.6 UEF, at parity).

Which Specs Set State HPAX-40-DHPT 2** Apart From Cohort Averages?

Ranked #401 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, State HPAX-40-DHPT 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 3417481
Model NumberHPAX-40-DHPT 2**Draw pattern: Medium-UsageHPAX-40-DHPT 2**
Uniform Energy Factor (UEF)3.6-0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency426%-3.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)66" H x 20" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Do Regional kWh Prices Impact HPAX-40-DHPT 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, State HPAX-40-DHPT 2**'s 902 kWh/yr draw translates to roughly $164/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,772
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $12,399
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,818
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $4,181
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,845
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should State Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your HPAX-40-DHPT 2** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
American HPA10240H045DV 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
Lochinvar CHPA-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
RELIANCE WATER HEATERS 10-40-DHPTA 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
A. O. Smith HPA10-40H45DV 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902

Which Home Setups Are NOT a Fit for State HPAX-40-DHPT 2**?

Comparing State HPAX-40-DHPT 2** against A. O. Smith CAHP-40 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • State HPAX-40-DHPT 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State HPAX-40-DHPT 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HPAX-40-DHPT 2** Strong Fit — 3.6 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-40 2** footprint.

Frequently Asked Technical Questions: State HPAX-40-DHPT 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does State HPAX-40-DHPT 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; State HPAX-40-DHPT 2** logs 3.6 UEF (Pass: +1.30 / +56.5%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing State HPAX-40-DHPT 2**?

With a 66 in. height and 20 in. diameter, State HPAX-40-DHPT 2** fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (20" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits State HPAX-40-DHPT 2**?

Powered via 240V at 22A max, State HPAX-40-DHPT 2** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for State HPAX-40-DHPT 2**?

Annual electric spend for State HPAX-40-DHPT 2** (902 kWh/yr) averages $164/yr nationwide (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing State HPAX-40-DHPT 2**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on State HPAX-40-DHPT 2**.

Is State HPAX-40-DHPT 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies State HPAX-40-DHPT 2** at 55 gal First Hour Rating (-17 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does State have active CPSC SaferProducts notices affecting HPAX-40-DHPT 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches State HPAX-40-DHPT 2** (3.6 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for State HPAX-40-DHPT 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-40 2** (3.6 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)