Skip to main content
ENERGY STAR water heater model · PD 4529469

State SHPCO-45 1**+SXST-50LBG 1** Water Heater Specifications (3.55 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, State SHPCO-45 1**+SXST-50LBG 1** (Electric) achieves a certified 3.55 UEF rating across its 48-gallon nominal tank, 72 gal First Hour Rating (rank #414 of 706, PD 4529469) and verifies as Pass: +1.25 / +54.3% for 2029 DOE floors. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
72 gal
Storage Volume
48 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.25 / +54.3%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State SHPCO-45 1**+SXST-50LBG 1** at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30State SHPCO-45 1**+SXST-50LBG 1**: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State SHPCO-45 1**+SXST-50LBG 1** relative to the cohort median.
Efficiency comparison & rule summary

State SHPCO-45 1**+SXST-50LBG 1** records 3.55 UEF efficiency, putting it #414 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: State SHPCO-45 1**+SXST-50LBG 1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.25 UEF (+54.3%). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for State SHPCO-45 1**+SXST-50LBG 1** runs ~$166/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for State SHPCO-45 1**+SXST-50LBG 1**: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside State SHPCO-45 1**+SXST-50LBG 1** (3.55 UEF) are A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, at parity) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, at parity).

How Complete Are the Certified Metrics for State SHPCO-45 1**+SXST-50LBG 1**?

Standing at #414 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, State SHPCO-45 1**+SXST-50LBG 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 4529469
Model NumberSHPCO-45 1**+SXST-50LBG 1**Draw pattern: Medium-UsageSHPCO-45 1**+SXST-50LBG 1**
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)72 galAt 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use915 kWh/yr-157 kWh/yr vs. 1,072 kWh/yr medianEst. $166/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency428%-1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)33" H x 22.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-02-25Certified 2026-02-25Markets: United States

What Is the Projected Utility Bill for SHPCO-45 1**+SXST-50LBG 1** by State?

At 915 kWh/yr, State SHPCO-45 1**+SXST-50LBG 1** averages about $166/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (915 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$166.00/yrHawaii$432.00/yrCalifornia$272.00/yrTexas$146.00/yrWashington$134.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $166/yr $1,662 $4,751
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $432/yr $4,317 $12,342
California 29.75 ¢/kWh ($0.2975) $272/yr $2,722 $7,783
Texas 15.91 ¢/kWh ($0.1591) $146/yr $1,456 $4,162
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $134/yr $1,339 $3,827
Estimated electricity spend (915 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which 5 Models Offer Similar Output to SHPCO-45 1**+SXST-50LBG 1**?

Ordered by minimal capacity and UEF spread relative to State SHPCO-45 1**+SXST-50LBG 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
American MHPCO-45 1**+MXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915

What Are the Limitations of State SHPCO-45 1**+SXST-50LBG 1** and Who Should Not Install It?

Before ordering State SHPCO-45 1**+SXST-50LBG 1** (Hybrid/Electric Heat Pump, 3.55 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • State SHPCO-45 1**+SXST-50LBG 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-50LBG 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State SHPCO-45 1**+SXST-50LBG 1** Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

Practical Specs & Code Questions for State SHPCO-45 1**+SXST-50LBG 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does State SHPCO-45 1**+SXST-50LBG 1** pass the May 6, 2029 federal DOE efficiency rule?

State SHPCO-45 1**+SXST-50LBG 1** carries a verified 3.55 UEF rating (Pass: +1.25 / +54.3%), ranking #414 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does State SHPCO-45 1**+SXST-50LBG 1** need?

State SHPCO-45 1**+SXST-50LBG 1** stands 33 in. high with a 22.5 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does State SHPCO-45 1**+SXST-50LBG 1** require?

State SHPCO-45 1**+SXST-50LBG 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does State SHPCO-45 1**+SXST-50LBG 1** cost per year to run?

Rated at 915 kWh/yr, State SHPCO-45 1**+SXST-50LBG 1** costs about $166/yr ($1,660 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii).

Who should NOT install State SHPCO-45 1**+SXST-50LBG 1**, and what are its limits?

State SHPCO-45 1**+SXST-50LBG 1** (3.55 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can State SHPCO-45 1**+SXST-50LBG 1** serve at peak demand?

State SHPCO-45 1**+SXST-50LBG 1** achieves a 72 gal First Hour Rating (At 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for State SHPCO-45 1**+SXST-50LBG 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to State SHPCO-45 1**+SXST-50LBG 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks