State SHPCO-45 1**+SXST-66 1** Water Heater Specifications (3.7 UEF)
With PD 4529448 certification, State SHPCO-45 1**+SXST-66 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.7 UEF rating across its 60-gallon nominal tank, 82 gal First Hour Rating, standing #347 of 706 across 706 peers with Pass: +1.20 / +48.0% for May 6, 2029. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 82 gal
- Storage Volume
- 60 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

ENERGY STAR certification places State SHPCO-45 1**+SXST-66 1** at 3.7 UEF (#347 of 706; At 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: State SHPCO-45 1**+SXST-66 1** stands +1.20 UEF (+48.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for State SHPCO-45 1**+SXST-66 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for State SHPCO-45 1**+SXST-66 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF, at parity) and American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity) bracket State SHPCO-45 1**+SXST-66 1**.
How Complete Are the Certified Metrics for State SHPCO-45 1**+SXST-66 1**?
Standing at #347 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, State SHPCO-45 1**+SXST-66 1** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | State | 81 certified listings | ENERGY STAR PD 4529448 |
| Model Number | SHPCO-45 1**+SXST-66 1** | Draw pattern: High-Usage | SHPCO-45 1**+SXST-66 1** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,341 kWh/yr | +269 kWh/yr vs. 1,072 kWh/yr median | Est. $244/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |
What Is the Projected Utility Bill for SHPCO-45 1**+SXST-66 1** by State?
At 1,341 kWh/yr, State SHPCO-45 1**+SXST-66 1** averages about $244/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $244/yr | $2,435 | $7,358 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $633/yr | $6,327 | $19,117 |
| California | 29.75 ¢/kWh ($0.2975) | $399/yr | $3,989 | $12,055 |
| Texas | 15.91 ¢/kWh ($0.1591) | $213/yr | $2,134 | $6,447 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $196/yr | $1,962 | $5,928 |
Are State Models Affected by Current CPSC Notices?
Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
Which 5 Models Offer Similar Output to SHPCO-45 1**+SXST-66 1**?
Ordered by minimal capacity and UEF spread relative to State SHPCO-45 1**+SXST-66 1**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| American MHPCO-45 1**+MXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| Giant GTHPCO-45 1**+GTXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| A. O. Smith HPACO-45 1**+AXST-66TTP 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
Who Is State SHPCO-45 1**+SXST-66 1** Best For — and When Should You Pick A. O. Smith HPACO-45 1**+AXST-66 1**?
Evaluate whether State SHPCO-45 1**+SXST-66 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- State SHPCO-45 1**+SXST-66 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting State SHPCO-45 1**+SXST-66 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for State SHPCO-45 1**+SXST-66 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does State SHPCO-45 1**+SXST-66 1** (3.7 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State SHPCO-45 1**+SXST-66 1** records 3.7 UEF (Pass: +1.20 / +48.0%), placing #347 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does State SHPCO-45 1**+SXST-66 1** fit inside a tight hallway closet or low-headroom utility room?
State SHPCO-45 1**+SXST-66 1** requires room for its 59 in. vertical shell and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern State SHPCO-45 1**+SXST-66 1**?
For State SHPCO-45 1**+SXST-66 1**, plan a 240V circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for State SHPCO-45 1**+SXST-66 1**?
Using 1,341 kWh/yr, State SHPCO-45 1**+SXST-66 1** generates an estimated $244/yr electric bill at 18.16 cents/kWh (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of State SHPCO-45 1**+SXST-66 1** (3.7 UEF)?
State SHPCO-45 1**+SXST-66 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPACO-45 1**+AXST-66 1**.
What hot-water delivery rating governs State SHPCO-45 1**+SXST-66 1**?
Rated for 82 gal FHR (+10 gal vs. 72 gal median), State SHPCO-45 1**+SXST-66 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen State SHPCO-45 1**+SXST-66 1** for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to State SHPCO-45 1**+SXST-66 1** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)