Skip to main content
ENERGY STAR water heater model · PD 3626853

STEALTH ACIQ-80G-HP-WH Water Heater Specifications (4 UEF)

With PD 3626853 certification, STEALTH ACIQ-80G-HP-WH (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating, standing #106 of 706 across 706 peers with Pass: +1.50 / +60.0% for May 6, 2029. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Uniform Energy Factor
4.0 UEF
Cohort UEF Rank
#106 of 706 (top 19.8%)
First Hour Rating
91 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.50 / +60.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking STEALTH ACIQ-80G-HP-WH at 4.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50STEALTH ACIQ-80G-HP-WH: 4.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows STEALTH ACIQ-80G-HP-WH relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places STEALTH ACIQ-80G-HP-WH at 4.0 UEF (#106 of 706; +0.30 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: STEALTH ACIQ-80G-HP-WH stands +1.50 UEF (+60.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for STEALTH ACIQ-80G-HP-WH runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for STEALTH ACIQ-80G-HP-WH: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity) bracket STEALTH ACIQ-80G-HP-WH.

How Complete Are the Certified Metrics for STEALTH ACIQ-80G-HP-WH?

Standing at #106 of 706 (top 19.8%) among 706 certified Hybrid/Electric Heat Pump heaters, STEALTH ACIQ-80G-HP-WH brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandSTEALTH2 certified listingsENERGY STAR PD 3626853
Model NumberACIQ-80G-HP-WHDraw pattern: High-UsageACIQ-80G-HP-WH
Uniform Energy Factor (UEF)4.0+0.30 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,240 kWh/yr+168 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency450%+21.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)41.7" H x 21.8" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-11Certified 2024-11-11Markets: United States, Canada

What Is the Projected Utility Bill for ACIQ-80G-HP-WH by State?

At 1,240 kWh/yr, STEALTH ACIQ-80G-HP-WH averages about $225/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,240 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$585.00/yrCalifornia$369.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,252 $7,538
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $585/yr $5,850 $19,584
California 29.75 ¢/kWh ($0.2975) $369/yr $3,689 $12,349
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,973 $6,604
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,814 $6,073
Estimated electricity spend (1,240 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are STEALTH Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched STEALTH in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to ACIQ-80G-HP-WH?

Ordered by minimal capacity and UEF spread relative to STEALTH ACIQ-80G-HP-WH, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
ACIQ ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80CA Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Custom Comfort CCOHPWH80A Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240
Bosch TR7000T - 80US Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (at parity) 1,240

Which Home Setups Are NOT a Fit for STEALTH ACIQ-80G-HP-WH?

Comparing STEALTH ACIQ-80G-HP-WH against 1HVAC ACIQ-80G-HP-WH requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • STEALTH ACIQ-80G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting STEALTH ACIQ-80G-HP-WH directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing STEALTH ACIQ-80G-HP-WH Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

Practical Specs & Code Questions for STEALTH ACIQ-80G-HP-WH

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does STEALTH ACIQ-80G-HP-WH score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; STEALTH ACIQ-80G-HP-WH logs 4.0 UEF (Pass: +1.50 / +60.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing STEALTH ACIQ-80G-HP-WH?

With a 41.7 in. height and 21.8 in. diameter, STEALTH ACIQ-80G-HP-WH fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits STEALTH ACIQ-80G-HP-WH?

Powered via 240V at 24A max, STEALTH ACIQ-80G-HP-WH requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for STEALTH ACIQ-80G-HP-WH?

Annual electric spend for STEALTH ACIQ-80G-HP-WH (1,240 kWh/yr) averages $225/yr nationwide (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing STEALTH ACIQ-80G-HP-WH?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on STEALTH ACIQ-80G-HP-WH.

Is STEALTH ACIQ-80G-HP-WH sized adequately for a 2-to-4-person household?

ENERGY STAR certifies STEALTH ACIQ-80G-HP-WH at 91 gal First Hour Rating (+19 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does STEALTH have active CPSC SaferProducts notices affecting ACIQ-80G-HP-WH?

Zero CPSC recall alerts matched STEALTH (2026-11-23 check). Keep your STEALTH ACIQ-80G-HP-WH serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches STEALTH ACIQ-80G-HP-WH (4.0 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for STEALTH ACIQ-80G-HP-WH. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks