Skip to main content
ENERGY STAR water heater model · PD 4689617

A. O. Smith CAHP-80 2** Water Heater Specifications (3.88 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, A. O. Smith CAHP-80 2** achieves a certified 3.88 UEF rating across its 81-gallon nominal tank, 95 gal First Hour Rating and ranks #165 of 706 in its 706-model cohort (PD 4689617), recording Pass: +1.38 / +55.2% under 2029 DOE rules. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10280H045DV 2** (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
95 gal
Storage Volume
81 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith CAHP-80 2** at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith CAHP-80 2**: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith CAHP-80 2** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, A. O. Smith CAHP-80 2** logs 3.88 UEF and ranks #165 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), A. O. Smith CAHP-80 2** holds a +1.38 UEF (+55.2%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for A. O. Smith CAHP-80 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith CAHP-80 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping A. O. Smith CAHP-80 2** (3.88 UEF)? Check American HPA10280H045DV 2** (3.88 UEF, at parity) and Lochinvar CHPA-80 2** (3.88 UEF, at parity).

What Physical and Thermal Ratings Define A. O. Smith CAHP-80 2**?

Positioning at #165 of 706 (top 30.6%) out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith CAHP-80 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4689617
Model NumberCAHP-80 2**Draw pattern: High-UsageCAHP-80 2**
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,279 kWh/yr+207 kWh/yr vs. 1,072 kWh/yr medianEst. $232/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency428%-1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-08-13Certified 2026-08-13Markets: United States

Why Do State Utility Rates Shift CAHP-80 2** Running Costs?

Consuming 1,279 kWh annually puts A. O. Smith CAHP-80 2** near $232/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,279 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$232.00/yrHawaii$603.00/yrCalifornia$381.00/yrTexas$203.00/yrWashington$187.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $232/yr $2,323 $7,473
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $603/yr $6,034 $19,415
California 29.75 ¢/kWh ($0.2975) $381/yr $3,805 $12,242
Texas 15.91 ¢/kWh ($0.1591) $203/yr $2,035 $6,547
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $187/yr $1,871 $6,020
Estimated electricity spend (1,279 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to A. O. Smith CAHP-80 2**?

Homeowners cross-shopping A. O. Smith CAHP-80 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPA10280H045DV 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
Lochinvar CHPA-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
RELIANCE WATER HEATERS 10-80-DHPTA 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
State CSHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
Lochinvar HPPA080KD 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279

What Installation Caveats Apply Before Buying A. O. Smith CAHP-80 2**?

Even high-UEF units like A. O. Smith CAHP-80 2** (3.88 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith CAHP-80 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith CAHP-80 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith CAHP-80 2** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPA10280H045DV 2** footprint.

Sizing, Efficiency & Recall Answers for A. O. Smith CAHP-80 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith CAHP-80 2** eligible for continued manufacture past May 6, 2029?

At 3.88 UEF, A. O. Smith CAHP-80 2** achieves Pass: +1.38 / +55.2% for the 2029 DOE standard and stands #165 of 706 (top 30.6%) against American HPA10280H045DV 2** and Lochinvar CHPA-80 2**.

How tall and wide is A. O. Smith CAHP-80 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith CAHP-80 2** are 69 in. height and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith CAHP-80 2** require upgrading household electrical panels or gas piping?

A. O. Smith CAHP-80 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is A. O. Smith CAHP-80 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $232/yr ($2,320 over 10 years) to power A. O. Smith CAHP-80 2** at 1,279 kWh/yr under the 18.16 cents/kWh US average (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii).

Which installation bottlenecks limit A. O. Smith CAHP-80 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith CAHP-80 2** drops into resistance mode more often.

How does A. O. Smith CAHP-80 2** handle simultaneous showers and laundry?

Delivering 95 gal in the first hour (+23 gal vs. 72 gal median), A. O. Smith CAHP-80 2** combines 81 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith CAHP-80 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith CAHP-80 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPA10280H045DV 2** (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks