Skip to main content
ENERGY STAR water heater model · PD 4689621

State CSHP-80 2** Water Heater Specifications (3.88 UEF)

Certified at 3.88 UEF across its 81-gallon nominal tank, 95 gal First Hour Rating, State CSHP-80 2** (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 4689621). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.38 / +55.2%. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-80 2** (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
95 gal
Storage Volume
81 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State CSHP-80 2** at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State CSHP-80 2**: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State CSHP-80 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.88 UEF, State CSHP-80 2** places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).

State CSHP-80 2** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.38 UEF (+55.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for State CSHP-80 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for State CSHP-80 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to State CSHP-80 2** include A. O. Smith CAHP-80 2** (3.88 UEF, at parity) alongside American HPA10280H045DV 2** (3.88 UEF, at parity).

How Do State CSHP-80 2** Specs Compare to Hybrid/Electric Heat Pump Medians?

State CSHP-80 2** places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 4689621
Model NumberCSHP-80 2**Draw pattern: High-UsageCSHP-80 2**
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,279 kWh/yr+207 kWh/yr vs. 1,072 kWh/yr medianEst. $232/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency428%-1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-08-13Certified 2026-08-13Markets: United States

What Does CSHP-80 2** Cost to Operate Across State Electricity Rates?

At 1,279 kWh/yr, State CSHP-80 2** runs roughly $232/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,279 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$232.00/yrHawaii$603.00/yrCalifornia$381.00/yrTexas$203.00/yrWashington$187.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $232/yr $2,323 $7,473
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $603/yr $6,034 $19,415
California 29.75 ¢/kWh ($0.2975) $381/yr $3,805 $12,242
Texas 15.91 ¢/kWh ($0.1591) $203/yr $2,035 $6,547
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $187/yr $1,871 $6,020
Estimated electricity spend (1,279 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for State Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with State; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match CSHP-80 2** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to State CSHP-80 2** by storage capacity and 3.88 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
American HPA10280H045DV 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
Lochinvar CHPA-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
RELIANCE WATER HEATERS 10-80-DHPTA 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
A. O. Smith HPA10-80H45DV 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279

Who Is State CSHP-80 2** Best For — and When Should You Pick A. O. Smith CAHP-80 2**?

Evaluate whether State CSHP-80 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • State CSHP-80 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State CSHP-80 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State CSHP-80 2** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-80 2** footprint.

What Are the Key Questions About State CSHP-80 2**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does State CSHP-80 2** (3.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State CSHP-80 2** records 3.88 UEF (Pass: +1.38 / +55.2%), placing #165 of 706 (top 30.6%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does State CSHP-80 2** fit inside a tight hallway closet or low-headroom utility room?

State CSHP-80 2** requires room for its 69 in. vertical shell and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern State CSHP-80 2**?

For State CSHP-80 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for State CSHP-80 2**?

Using 1,279 kWh/yr, State CSHP-80 2** generates an estimated $232/yr electric bill at 18.16 cents/kWh (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of State CSHP-80 2** (3.88 UEF)?

State CSHP-80 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith CAHP-80 2**.

What hot-water delivery rating governs State CSHP-80 2**?

Rated for 95 gal FHR (+23 gal vs. 72 gal median), State CSHP-80 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen State CSHP-80 2** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to State CSHP-80 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-80 2** (3.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks