Skip to main content
ENERGY STAR water heater model · PD 3417566

RELIANCE WATER HEATERS 10-80-DHPTA 2** Water Heater Specifications (3.88 UEF)

Certified at 3.88 UEF across its 81-gallon nominal tank, 95 gal First Hour Rating, RELIANCE WATER HEATERS 10-80-DHPTA 2** (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 3417566). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.38 / +55.2%. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-80 2** (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
95 gal
Storage Volume
81 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking RELIANCE WATER HEATERS 10-80-DHPTA 2** at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50RELIANCE WATER HEATERS 10-80-DHPTA 2**: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-80-DHPTA 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.88 UEF, RELIANCE WATER HEATERS 10-80-DHPTA 2** places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).

RELIANCE WATER HEATERS 10-80-DHPTA 2** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.38 UEF (+55.2% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for RELIANCE WATER HEATERS 10-80-DHPTA 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 10-80-DHPTA 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to RELIANCE WATER HEATERS 10-80-DHPTA 2** include A. O. Smith CAHP-80 2** (3.88 UEF, at parity) alongside American HPA10280H045DV 2** (3.88 UEF, at parity).

How Complete Are the Certified Metrics for RELIANCE WATER HEATERS 10-80-DHPTA 2**?

Standing at #165 of 706 (top 30.6%) among 706 certified Hybrid/Electric Heat Pump heaters, RELIANCE WATER HEATERS 10-80-DHPTA 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 3417566
Model Number10-80-DHPTA 2**Draw pattern: High-Usage10-80-DHPTA 2**
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,279 kWh/yr+207 kWh/yr vs. 1,072 kWh/yr medianEst. $232/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency428%-1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Is the Projected Utility Bill for 10-80-DHPTA 2** by State?

At 1,279 kWh/yr, RELIANCE WATER HEATERS 10-80-DHPTA 2** averages about $232/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,279 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$232.00/yrHawaii$603.00/yrCalifornia$381.00/yrTexas$203.00/yrWashington$187.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $232/yr $2,323 $7,473
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $603/yr $6,034 $19,415
California 29.75 ¢/kWh ($0.2975) $381/yr $3,805 $12,242
Texas 15.91 ¢/kWh ($0.1591) $203/yr $2,035 $6,547
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $187/yr $1,871 $6,020
Estimated electricity spend (1,279 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are RELIANCE WATER HEATERS Models Affected by Current CPSC Notices?

Review 3 brand-matched CPSC entries pulled 2026-11-23 for RELIANCE WATER HEATERS and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which 5 Models Offer Similar Output to 10-80-DHPTA 2**?

Ordered by minimal capacity and UEF spread relative to RELIANCE WATER HEATERS 10-80-DHPTA 2**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith CAHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
American HPA10280H045DV 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
Lochinvar CHPA-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
State CSHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
A. O. Smith HPA10-80H45DV 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279

What Installation Caveats Apply Before Buying RELIANCE WATER HEATERS 10-80-DHPTA 2**?

Even high-UEF units like RELIANCE WATER HEATERS 10-80-DHPTA 2** (3.88 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS 10-80-DHPTA 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-80-DHPTA 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing RELIANCE WATER HEATERS 10-80-DHPTA 2** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith CAHP-80 2** footprint.

Practical Specs & Code Questions for RELIANCE WATER HEATERS 10-80-DHPTA 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is RELIANCE WATER HEATERS 10-80-DHPTA 2** eligible for continued manufacture past May 6, 2029?

At 3.88 UEF, RELIANCE WATER HEATERS 10-80-DHPTA 2** achieves Pass: +1.38 / +55.2% for the 2029 DOE standard and stands #165 of 706 (top 30.6%) against A. O. Smith CAHP-80 2** and American HPA10280H045DV 2**.

How tall and wide is RELIANCE WATER HEATERS 10-80-DHPTA 2**, and what service clearance is needed?

Physical dimensions for RELIANCE WATER HEATERS 10-80-DHPTA 2** are 69 in. height and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)); verify stair turns and drain pan width before delivery.

Will RELIANCE WATER HEATERS 10-80-DHPTA 2** require upgrading household electrical panels or gas piping?

RELIANCE WATER HEATERS 10-80-DHPTA 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is RELIANCE WATER HEATERS 10-80-DHPTA 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $232/yr ($2,320 over 10 years) to power RELIANCE WATER HEATERS 10-80-DHPTA 2** at 1,279 kWh/yr under the 18.16 cents/kWh US average (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii).

Which installation bottlenecks limit RELIANCE WATER HEATERS 10-80-DHPTA 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, RELIANCE WATER HEATERS 10-80-DHPTA 2** drops into resistance mode more often.

How does RELIANCE WATER HEATERS 10-80-DHPTA 2** handle simultaneous showers and laundry?

Delivering 95 gal in the first hour (+23 gal vs. 72 gal median), RELIANCE WATER HEATERS 10-80-DHPTA 2** combines 81 gal tank storage with rapid burner/element recovery.

How long is the warranty on RELIANCE WATER HEATERS 10-80-DHPTA 2** and how do you decode its serial?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying RELIANCE WATER HEATERS 10-80-DHPTA 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-80 2** (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)