Skip to main content
ENERGY STAR water heater model · PD 4518074

State GP-8-50-*TPDT 4** Water Heater Specifications (0.88 UEF)

In the 71-unit Gas-fired Storage Residential-duty Commercial class, State GP-8-50-*TPDT 4** (Natural Gas, Propane) achieves a certified 0.88 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating (rank #34 of 71, PD 4518074) and verifies as Pass: +0.30 / +51.7% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Closest certified alternative is A. O. Smith HDHE-50 4** (0.88 UEF).

Uniform Energy Factor
0.88 UEF
Cohort UEF Rank
#34 of 71
First Hour Rating
118 gal
Storage Volume
49 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.30 / +51.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking State GP-8-50-*TPDT 4** at 0.88 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58State GP-8-50-*TPDT 4**: 0.88
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows State GP-8-50-*TPDT 4** relative to the cohort median.
Efficiency comparison & rule summary

State GP-8-50-*TPDT 4** records 0.88 UEF efficiency, putting it #34 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers.

State gp-8-50-*tpdt 4** stores 49 gal nominal; 118 gal first hour rating (-18 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d).

Competing options beside State GP-8-50-*TPDT 4** (0.88 UEF) are A. O. Smith HDHE-50 4** (0.88 UEF, at parity) and American VG8250T100*V (0.88 UEF, at parity).

What Physical and Thermal Ratings Define State GP-8-50-*TPDT 4**?

Positioning at #34 of 71 out of 71 Gas-fired Storage Residential-duty Commercial peers, State GP-8-50-*TPDT 4** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 4518074
Model NumberGP-8-50-*TPDT 4**Draw pattern: High-UsageGP-8-50-*TPDT 4**
Uniform Energy Factor (UEF)0.88At 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)118 gal-18 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+2.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)55.7" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-12-12Certified 2025-12-12Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any State Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under State; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

What Are 5 Direct Alternatives to State GP-8-50-*TPDT 4**?

Homeowners cross-shopping State GP-8-50-*TPDT 4** frequently review these five Gas-fired Storage Residential-duty Commercial models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HDHE-50 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
American VG8250T100*V Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
GSW WATER HEATERS 8G-50100*PDV-H06* 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
RELIANCE WATER HEATERS 8-50-*TPDT 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
A. O. Smith GDHE-50 3** Gas-fired Storage Residential-duty Commercial 49 gal 100 gal 0.88 (at parity) —

When Should Homeowners Skip State GP-8-50-*TPDT 4** (Gas-fired Storage Residential-duty Commercial)?

Check State GP-8-50-*TPDT 4**'s mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.30 / +51.7% status—against typical residential installations.

Key Limitations & Exclusions

  • State GP-8-50-*TPDT 4** logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect State GP-8-50-*TPDT 4**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for State GP-8-50-*TPDT 4** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith HDHE-50 4**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Sizing, Efficiency & Recall Answers for State GP-8-50-*TPDT 4**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will State GP-8-50-*TPDT 4** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.88 UEF, State GP-8-50-*TPDT 4** shows Pass: +0.30 / +51.7% relative to May 6, 2029 federal DOE limits while placing #34 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers like A. O. Smith HDHE-50 4**.

Will State GP-8-50-*TPDT 4** fit through a standard utility door and 72-inch basement ceiling?

Measuring 55.7 in. tall by 18 in. diameter, State GP-8-50-*TPDT 4** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support State GP-8-50-*TPDT 4** during replacement?

Fueled by Natural Gas, Propane, State GP-8-50-*TPDT 4** specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for State GP-8-50-*TPDT 4**?

Because State GP-8-50-*TPDT 4** burns Natural Gas, Propane at 0.88 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.

When is State GP-8-50-*TPDT 4** a poor fit for a residential replacement?

Avoid State GP-8-50-*TPDT 4** if household peak demand surpasses 118 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

What First Hour Rating or flow capacity does State GP-8-50-*TPDT 4** deliver?

With 118 gal FHR (-18 gal vs. 136 gal median), State GP-8-50-*TPDT 4** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on State GP-8-50-*TPDT 4**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does State GP-8-50-*TPDT 4** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for State GP-8-50-*TPDT 4**. Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-50 4** (0.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks