State GP-8-50-*TPDT 4** Water Heater Specifications (0.88 UEF)
In the 71-unit Gas-fired Storage Residential-duty Commercial class, State GP-8-50-*TPDT 4** (Natural Gas, Propane) achieves a certified 0.88 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating (rank #34 of 71, PD 4518074) and verifies as Pass: +0.30 / +51.7% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Closest certified alternative is A. O. Smith HDHE-50 4** (0.88 UEF).
- Uniform Energy Factor
- 0.88 UEF
- Cohort UEF Rank
- #34 of 71
- First Hour Rating
- 118 gal
- Storage Volume
- 49 gal
- Fuel / Type
- Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
- DOE 2029 Rule Status
- Pass: +0.30 / +51.7%

State GP-8-50-*TPDT 4** records 0.88 UEF efficiency, putting it #34 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers.
State gp-8-50-*tpdt 4** stores 49 gal nominal; 118 gal first hour rating (-18 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d).
Competing options beside State GP-8-50-*TPDT 4** (0.88 UEF) are A. O. Smith HDHE-50 4** (0.88 UEF, at parity) and American VG8250T100*V (0.88 UEF, at parity).
What Physical and Thermal Ratings Define State GP-8-50-*TPDT 4**?
Positioning at #34 of 71 out of 71 Gas-fired Storage Residential-duty Commercial peers, State GP-8-50-*TPDT 4** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | State | 81 certified listings | ENERGY STAR PD 4518074 |
| Model Number | GP-8-50-*TPDT 4** | Draw pattern: High-Usage | GP-8-50-*TPDT 4** |
| Uniform Energy Factor (UEF) | 0.88 | At 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 118 gal | -18 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 97% | +2.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 55.7" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
Have Any State Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under State; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)
What Are 5 Direct Alternatives to State GP-8-50-*TPDT 4**?
Homeowners cross-shopping State GP-8-50-*TPDT 4** frequently review these five Gas-fired Storage Residential-duty Commercial models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HDHE-50 4** | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (at parity) | — |
| American VG8250T100*V | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (at parity) | — |
| GSW WATER HEATERS 8G-50100*PDV-H06* 4** | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (at parity) | — |
| RELIANCE WATER HEATERS 8-50-*TPDT 4** | Gas-fired Storage Residential-duty Commercial | 49 gal | 118 gal | 0.88 (at parity) | — |
| A. O. Smith GDHE-50 3** | Gas-fired Storage Residential-duty Commercial | 49 gal | 100 gal | 0.88 (at parity) | — |
When Should Homeowners Skip State GP-8-50-*TPDT 4** (Gas-fired Storage Residential-duty Commercial)?
Check State GP-8-50-*TPDT 4**'s mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.30 / +51.7% status—against typical residential installations.
Key Limitations & Exclusions
- State GP-8-50-*TPDT 4** logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect State GP-8-50-*TPDT 4**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for State GP-8-50-*TPDT 4**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will State GP-8-50-*TPDT 4** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 0.88 UEF, State GP-8-50-*TPDT 4** shows Pass: +0.30 / +51.7% relative to May 6, 2029 federal DOE limits while placing #34 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers like A. O. Smith HDHE-50 4**.
Will State GP-8-50-*TPDT 4** fit through a standard utility door and 72-inch basement ceiling?
Measuring 55.7 in. tall by 18 in. diameter, State GP-8-50-*TPDT 4** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support State GP-8-50-*TPDT 4** during replacement?
Fueled by Natural Gas, Propane, State GP-8-50-*TPDT 4** specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.
What is the estimated 10-year operating spend for State GP-8-50-*TPDT 4**?
Because State GP-8-50-*TPDT 4** burns Natural Gas, Propane at 0.88 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.
When is State GP-8-50-*TPDT 4** a poor fit for a residential replacement?
Avoid State GP-8-50-*TPDT 4** if household peak demand surpasses 118 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.
What First Hour Rating or flow capacity does State GP-8-50-*TPDT 4** deliver?
With 118 gal FHR (-18 gal vs. 136 gal median), State GP-8-50-*TPDT 4** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on State GP-8-50-*TPDT 4**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does State GP-8-50-*TPDT 4** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for State GP-8-50-*TPDT 4**. Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-50 4** (0.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)