Skip to main content
ENERGY STAR water heater model · PD 4518073

GSW WATER HEATERS 8G-50100*PDV-H06* 4** Water Heater Specifications (0.88 UEF)

With PD 4518073 certification, GSW WATER HEATERS 8G-50100*PDV-H06* 4** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.88 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating, standing #34 of 71 across 71 peers with Pass: +0.30 / +51.7% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Closest certified alternative is A. O. Smith HDHE-50 4** (0.88 UEF).

Uniform Energy Factor
0.88 UEF
Cohort UEF Rank
#34 of 71
First Hour Rating
118 gal
Storage Volume
49 gal
Fuel / Type
Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial
DOE 2029 Rule Status
Pass: +0.30 / +51.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas-fired Storage Residential-duty Commercial, marking GSW WATER HEATERS 8G-50100*PDV-H06* 4** at 0.88 UEF.1012726610.86 UEF0.93 UEFMedian 0.882029 min 0.58GSW WATER HEATERS 8G-50100*PDV-H06* 4**: 0.88
Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows GSW WATER HEATERS 8G-50100*PDV-H06* 4** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places GSW WATER HEATERS 8G-50100*PDV-H06* 4** at 0.88 UEF (#34 of 71; At 0.88 UEF median) in Gas-fired Storage Residential-duty Commercial.

Gsw water heaters 8g-50100*pdv-h06* 4** stores 49 gal nominal; 118 gal first hour rating (-18 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d).

In the Gas-fired Storage Residential-duty Commercial tier, A. O. Smith HDHE-50 4** (0.88 UEF, at parity) and American VG8250T100*V (0.88 UEF, at parity) bracket GSW WATER HEATERS 8G-50100*PDV-H06* 4**.

Which Specs Set GSW WATER HEATERS 8G-50100*PDV-H06* 4** Apart From Cohort Averages?

Ranked #34 of 71 inside the 71-model Gas-fired Storage Residential-duty Commercial cohort, GSW WATER HEATERS 8G-50100*PDV-H06* 4** is evaluated row by row below against category medians.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGSW WATER HEATERS33 certified listingsENERGY STAR PD 4518073
Model Number8G-50100*PDV-H06* 4**Draw pattern: High-Usage8G-50100*PDV-H06* 4**
Uniform Energy Factor (UEF)0.88At 0.88 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)118 gal-18 gal vs. 136 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency97%+2.0 pts vs. 95.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)55.7" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should GSW WATER HEATERS Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for GSW WATER HEATERS; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Gas-fired Storage Residential-duty Commercial Models Stack Up?

Five alternative Gas-fired Storage Residential-duty Commercial units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HDHE-50 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
American VG8250T100*V Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
RELIANCE WATER HEATERS 8-50-*TPDT 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
State GP-8-50-*TPDT 4** Gas-fired Storage Residential-duty Commercial 49 gal 118 gal 0.88 (at parity) —
A. O. Smith GDHE-50 3** Gas-fired Storage Residential-duty Commercial 49 gal 100 gal 0.88 (at parity) —

What Installation Caveats Apply Before Buying GSW WATER HEATERS 8G-50100*PDV-H06* 4**?

Even high-UEF units like GSW WATER HEATERS 8G-50100*PDV-H06* 4** (0.88 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • GSW WATER HEATERS 8G-50100*PDV-H06* 4** logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect GSW WATER HEATERS 8G-50100*PDV-H06* 4**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for GSW WATER HEATERS 8G-50100*PDV-H06* 4** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith HDHE-50 4**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Frequently Asked Technical Questions: GSW WATER HEATERS 8G-50100*PDV-H06* 4**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is GSW WATER HEATERS 8G-50100*PDV-H06* 4** eligible for continued manufacture past May 6, 2029?

At 0.88 UEF, GSW WATER HEATERS 8G-50100*PDV-H06* 4** achieves Pass: +0.30 / +51.7% for the 2029 DOE standard and stands #34 of 71 against A. O. Smith HDHE-50 4** and American VG8250T100*V.

How tall and wide is GSW WATER HEATERS 8G-50100*PDV-H06* 4**, and what service clearance is needed?

Physical dimensions for GSW WATER HEATERS 8G-50100*PDV-H06* 4** are 55.7 in. height and 18 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d)); verify stair turns and drain pan width before delivery.

Will GSW WATER HEATERS 8G-50100*PDV-H06* 4** require upgrading household electrical panels or gas piping?

Check Natural Gas, Propane piping and venting for GSW WATER HEATERS 8G-50100*PDV-H06* 4** (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is GSW WATER HEATERS 8G-50100*PDV-H06* 4** economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for GSW WATER HEATERS 8G-50100*PDV-H06* 4** (Natural Gas, Propane, 0.88 UEF) hinge on household gallon demand and local gas utility tariffs compared with A. O. Smith HDHE-50 4**.

Which installation bottlenecks limit GSW WATER HEATERS 8G-50100*PDV-H06* 4**?

Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.30 / +51.7%) and physical doorway clearances before choosing GSW WATER HEATERS 8G-50100*PDV-H06* 4** over A. O. Smith HDHE-50 4**.

How does GSW WATER HEATERS 8G-50100*PDV-H06* 4** handle simultaneous showers and laundry?

Delivering 118 gal in the first hour (-18 gal vs. 136 gal median), GSW WATER HEATERS 8G-50100*PDV-H06* 4** combines 49 gal tank storage with rapid burner/element recovery.

How long is the warranty on GSW WATER HEATERS 8G-50100*PDV-H06* 4** and how do you decode its serial?

CPSC records show 0 active plumbing recalls for GSW WATER HEATERS as of 2026-11-23. Confirm install proof and serial manufacture year on GSW WATER HEATERS 8G-50100*PDV-H06* 4** before calling service.

How do 2026 post-OBBBA rebates affect buying GSW WATER HEATERS 8G-50100*PDV-H06* 4**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas-fired Storage Residential-duty Commercial is A. O. Smith HDHE-50 4** (0.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks