A. O. Smith HPA10-80H45DV 2** Water Heater Specifications (3.88 UEF)

The A. O. Smith HPA10-80H45DV 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 81-gallon nominal tank, 95 gal First Hour Rating, ranking #165 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3417565). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.38 / +55.2%. Rated annual electricity draw of 1,279 kWh/yr equates to roughly $232/yr ($2,323 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10280H045DV 2** (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
95 gal
Storage Volume
81 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.38 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPA10-80H45DV 2** at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPA10-80H45DV 2**: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPA10-80H45DV 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPA10-80H45DV 2** (3.88 UEF) ranks #165 of 706 Hybrid/Electric Heat Pump models — 52-way tie; top 30.6%, more efficient than 69.4% of Hybrid/Electric Heat Pump models, +0.18 UEF above the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPA10-80H45DV 2**: +1.38 UEF (+55.2%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,279 kWh/yr for A. O. Smith HPA10-80H45DV 2** runs ~$232/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPA10-80H45DV 2**: 10-year operating spend spans $1,871 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPA10-80H45DV 2** (3.88 UEF) compares closely with American HPA10280H045DV 2** (3.88 UEF, at parity) and Lochinvar CHPA-80 2** (3.88 UEF, at parity).

What Physical and Thermal Ratings Define A. O. Smith HPA10-80H45DV 2**?

Positioning at #165 of 706 (top 30.6%) out of 706 Hybrid/Electric Heat Pump peers, A. O. Smith HPA10-80H45DV 2** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 3417565
Model NumberHPA10-80H45DV 2**Draw pattern: High-UsageHPA10-80H45DV 2**
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,279 kWh/yr+207 kWh/yr vs. 1,072 kWh/yr medianEst. $232/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency428%-1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)69" H x 27" DVerify 72 in. vertical headroom; tight at 28 in. door (27" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

Why Do State Utility Rates Shift HPA10-80H45DV 2** Running Costs?

Consuming 1,279 kWh annually puts A. O. Smith HPA10-80H45DV 2** near $232/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,279 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$232.00/yrHawaii$603.00/yrCalifornia$381.00/yrTexas$203.00/yrWashington$187.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $232/yr $2,323 $7,473
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $603/yr $6,034 $19,415
California 29.75 ¢/kWh ($0.2975) $381/yr $3,805 $12,242
Texas 15.91 ¢/kWh ($0.1591) $203/yr $2,035 $6,547
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $187/yr $1,871 $6,020
Estimated electricity spend (1,279 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to A. O. Smith HPA10-80H45DV 2**?

Homeowners cross-shopping A. O. Smith HPA10-80H45DV 2** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPA10280H045DV 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
Lochinvar CHPA-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
RELIANCE WATER HEATERS 10-80-DHPTA 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
State CSHP-80 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279
Lochinvar HPPA080KD 2** Hybrid/Electric Heat Pump 81 gal 95 gal 3.88 (at parity) 1,279

What Installation Caveats Apply Before Buying A. O. Smith HPA10-80H45DV 2**?

Even high-UEF units like A. O. Smith HPA10-80H45DV 2** (3.88 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith HPA10-80H45DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPA10-80H45DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPA10-80H45DV 2** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPA10280H045DV 2** footprint.

Sizing, Efficiency & Recall Answers for A. O. Smith HPA10-80H45DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith HPA10-80H45DV 2** eligible for continued manufacture past May 6, 2029?

At 3.88 UEF, A. O. Smith HPA10-80H45DV 2** achieves Pass: +1.38 / +55.2% for the 2029 DOE standard and stands #165 of 706 (top 30.6%) against American HPA10280H045DV 2** and Lochinvar CHPA-80 2**.

How tall and wide is A. O. Smith HPA10-80H45DV 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPA10-80H45DV 2** are 69 in. height and 27 in. diameter (verify 72 in. vertical headroom; tight at 28 in. door (27" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith HPA10-80H45DV 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPA10-80H45DV 2** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is A. O. Smith HPA10-80H45DV 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $232/yr ($2,320 over 10 years) to power A. O. Smith HPA10-80H45DV 2** at 1,279 kWh/yr under the 18.16 cents/kWh US average (ranging from $187/yr in Washington hydro tiers up to $603/yr in Hawaii).

Which installation bottlenecks limit A. O. Smith HPA10-80H45DV 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPA10-80H45DV 2** drops into resistance mode more often.

How does A. O. Smith HPA10-80H45DV 2** handle simultaneous showers and laundry?

Delivering 95 gal in the first hour (+23 gal vs. 72 gal median), A. O. Smith HPA10-80H45DV 2** combines 81 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith HPA10-80H45DV 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith HPA10-80H45DV 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPA10280H045DV 2** (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks