Skip to main content
ENERGY STAR water heater model · PD 4529470

A. O. Smith HPACO-45 1**+AXST-80 1** Water Heater Specifications (3.8 UEF)

The A. O. Smith HPACO-45 1**+AXST-80 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating, ranking #268 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4529470). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.30 / +52.0%. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American MHPCO-45 1**+MXST-80 1** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
95 gal
Storage Volume
73 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +52.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPACO-45 1**+AXST-80 1** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPACO-45 1**+AXST-80 1**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPACO-45 1**+AXST-80 1** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF) ranks #268 of 706 Hybrid/Electric Heat Pump models — 29-way tie; top 41.9%, more efficient than 58.1% of Hybrid/Electric Heat Pump models, +0.10 UEF above the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPACO-45 1**+AXST-80 1**: +1.30 UEF (+52.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for A. O. Smith HPACO-45 1**+AXST-80 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPACO-45 1**+AXST-80 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF) compares closely with American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity) and Giant GTHPCO-45 1**+GTXST-80 1** (3.8 UEF, at parity).

How Do A. O. Smith HPACO-45 1**+AXST-80 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith HPACO-45 1**+AXST-80 1** places #268 of 706 (top 41.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4529470
Model NumberHPACO-45 1**+AXST-80 1**Draw pattern: High-UsageHPACO-45 1**+AXST-80 1**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,306 kWh/yr+234 kWh/yr vs. 1,072 kWh/yr medianEst. $237/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)58" H x 20" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: United States, Canada

What Does HPACO-45 1**+AXST-80 1** Cost to Operate Across State Electricity Rates?

At 1,306 kWh/yr, A. O. Smith HPACO-45 1**+AXST-80 1** runs roughly $237/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,306 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$237.00/yrHawaii$616.00/yrCalifornia$389.00/yrTexas$208.00/yrWashington$191.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $237/yr $2,372 $7,424
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $616/yr $6,162 $19,287
California 29.75 ¢/kWh ($0.2975) $389/yr $3,885 $12,162
Texas 15.91 ¢/kWh ($0.1591) $208/yr $2,078 $6,504
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $191/yr $1,911 $5,981
Estimated electricity spend (1,306 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match HPACO-45 1**+AXST-80 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith HPACO-45 1**+AXST-80 1** by storage capacity and 3.8 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American MHPCO-45 1**+MXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
Giant GTHPCO-45 1**+GTXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
John Wood JWHPCO-45 1**+JWXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
American MHPCO-45 1**+MXST-80TTP 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306

What Are the Limitations of A. O. Smith HPACO-45 1**+AXST-80 1** and Who Should Not Install It?

Before ordering A. O. Smith HPACO-45 1**+AXST-80 1** (Hybrid/Electric Heat Pump, 3.8 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • A. O. Smith HPACO-45 1**+AXST-80 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPACO-45 1**+AXST-80 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPACO-45 1**+AXST-80 1** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American MHPCO-45 1**+MXST-80 1** footprint.

What Are the Key Questions About A. O. Smith HPACO-45 1**+AXST-80 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does A. O. Smith HPACO-45 1**+AXST-80 1** pass the May 6, 2029 federal DOE efficiency rule?

A. O. Smith HPACO-45 1**+AXST-80 1** carries a verified 3.8 UEF rating (Pass: +1.30 / +52.0%), ranking #268 of 706 (top 41.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does A. O. Smith HPACO-45 1**+AXST-80 1** need?

A. O. Smith HPACO-45 1**+AXST-80 1** stands 58 in. high with a 20 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does A. O. Smith HPACO-45 1**+AXST-80 1** require?

A. O. Smith HPACO-45 1**+AXST-80 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does A. O. Smith HPACO-45 1**+AXST-80 1** cost per year to run?

Rated at 1,306 kWh/yr, A. O. Smith HPACO-45 1**+AXST-80 1** costs about $237/yr ($2,370 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii).

Who should NOT install A. O. Smith HPACO-45 1**+AXST-80 1**, and what are its limits?

A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can A. O. Smith HPACO-45 1**+AXST-80 1** serve at peak demand?

A. O. Smith HPACO-45 1**+AXST-80 1** achieves a 95 gal First Hour Rating (+23 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for A. O. Smith HPACO-45 1**+AXST-80 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to A. O. Smith HPACO-45 1**+AXST-80 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American MHPCO-45 1**+MXST-80 1** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks