Skip to main content
ENERGY STAR water heater model · PD 4529403

GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** Water Heater Specifications (3.8 UEF)

With PD 4529403 certification, GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating, standing #268 of 706 across 706 peers with Pass: +1.30 / +52.0% for May 6, 2029. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
95 gal
Storage Volume
73 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +52.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** at 3.8 UEF (#268 of 706; +0.10 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** stands +1.30 UEF (+52.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, at parity) and American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity) bracket GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**.

What Physical and Thermal Ratings Define GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**?

Positioning at #268 of 706 (top 41.9%) out of 706 Hybrid/Electric Heat Pump peers, GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGSW WATER HEATERS33 certified listingsENERGY STAR PD 4529403
Model NumberGHPCO-45 1**+GXST-80 1**Draw pattern: High-UsageGHPCO-45 1**+GXST-80 1**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,306 kWh/yr+234 kWh/yr vs. 1,072 kWh/yr medianEst. $237/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)58" H x 20" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States, Canada

Why Do State Utility Rates Shift GHPCO-45 1**+GXST-80 1** Running Costs?

Consuming 1,306 kWh annually puts GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** near $237/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,306 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$237.00/yrHawaii$616.00/yrCalifornia$389.00/yrTexas$208.00/yrWashington$191.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $237/yr $2,372 $7,424
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $616/yr $6,162 $19,287
California 29.75 ¢/kWh ($0.2975) $389/yr $3,885 $12,162
Texas 15.91 ¢/kWh ($0.1591) $208/yr $2,078 $6,504
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $191/yr $1,911 $5,981
Estimated electricity spend (1,306 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any GSW WATER HEATERS Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for GSW WATER HEATERS; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**?

Homeowners cross-shopping GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
American MHPCO-45 1**+MXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
Giant GTHPCO-45 1**+GTXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
John Wood JWHPCO-45 1**+JWXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
A. O. Smith HPACO-45 1**+AXST-80TTP 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306

What Are the Limitations of GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** and Who Should Not Install It?

Before ordering GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** (Hybrid/Electric Heat Pump, 3.8 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-80 1** footprint.

Sizing, Efficiency & Recall Answers for GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** pass the May 6, 2029 federal DOE efficiency rule?

GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** carries a verified 3.8 UEF rating (Pass: +1.30 / +52.0%), ranking #268 of 706 (top 41.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** need?

GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** stands 58 in. high with a 20 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** require?

GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** cost per year to run?

Rated at 1,306 kWh/yr, GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** costs about $237/yr ($2,370 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii).

Who should NOT install GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**, and what are its limits?

GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** (3.8 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** serve at peak demand?

GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** achieves a 95 gal First Hour Rating (+23 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**?

No active CPSC recalls matched GSW WATER HEATERS as of 2026-11-23. Always decode the serial tag on GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to GSW WATER HEATERS GHPCO-45 1**+GXST-80 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks