John Wood JWHPCO-45 1**+JWXST-80 1** Water Heater Specifications (3.8 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, John Wood JWHPCO-45 1**+JWXST-80 1** (Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating (rank #268 of 706, PD 4529404) and verifies as Pass: +1.30 / +52.0% for 2029 DOE floors. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).
- Uniform Energy Factor
- 3.8 UEF
- Cohort UEF Rank
- #268 of 706 (top 41.9%)
- First Hour Rating
- 95 gal
- Storage Volume
- 73 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.30 / +52.0%

John Wood JWHPCO-45 1**+JWXST-80 1** records 3.8 UEF efficiency, putting it #268 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: John Wood JWHPCO-45 1**+JWXST-80 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.30 UEF (+52.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for John Wood JWHPCO-45 1**+JWXST-80 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for John Wood JWHPCO-45 1**+JWXST-80 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside John Wood JWHPCO-45 1**+JWXST-80 1** (3.8 UEF) are A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, at parity) and American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity).
What Physical and Thermal Ratings Define John Wood JWHPCO-45 1**+JWXST-80 1**?
Positioning at #268 of 706 (top 41.9%) out of 706 Hybrid/Electric Heat Pump peers, John Wood JWHPCO-45 1**+JWXST-80 1** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | John Wood | 17 certified listings | ENERGY STAR PD 4529404 |
| Model Number | JWHPCO-45 1**+JWXST-80 1** | Draw pattern: High-Usage | JWHPCO-45 1**+JWXST-80 1** |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 95 gal | +23 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,306 kWh/yr | +234 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 423% | -6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58" H x 20" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-03-19 | Certified 2026-03-19 | Markets: United States, Canada |
Why Do State Utility Rates Shift JWHPCO-45 1**+JWXST-80 1** Running Costs?
Consuming 1,306 kWh annually puts John Wood JWHPCO-45 1**+JWXST-80 1** near $237/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,372 | $7,424 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $616/yr | $6,162 | $19,287 |
| California | 29.75 ¢/kWh ($0.2975) | $389/yr | $3,885 | $12,162 |
| Texas | 15.91 ¢/kWh ($0.1591) | $208/yr | $2,078 | $6,504 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,911 | $5,981 |
Have Any John Wood Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for John Wood; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to John Wood JWHPCO-45 1**+JWXST-80 1**?
Homeowners cross-shopping John Wood JWHPCO-45 1**+JWXST-80 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPACO-45 1**+AXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| American MHPCO-45 1**+MXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| Giant GTHPCO-45 1**+GTXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| A. O. Smith HPACO-45 1**+AXST-80TTP 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
When Should Homeowners Skip John Wood JWHPCO-45 1**+JWXST-80 1** (Hybrid/Electric Heat Pump)?
Check John Wood JWHPCO-45 1**+JWXST-80 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.30 / +52.0% status—against typical residential installations.
Key Limitations & Exclusions
- John Wood JWHPCO-45 1**+JWXST-80 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting John Wood JWHPCO-45 1**+JWXST-80 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for John Wood JWHPCO-45 1**+JWXST-80 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will John Wood JWHPCO-45 1**+JWXST-80 1** stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.8 UEF, John Wood JWHPCO-45 1**+JWXST-80 1** shows Pass: +1.30 / +52.0% relative to May 6, 2029 federal DOE limits while placing #268 of 706 (top 41.9%) among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPACO-45 1**+AXST-80 1**.
Will John Wood JWHPCO-45 1**+JWXST-80 1** fit through a standard utility door and 72-inch basement ceiling?
Measuring 58 in. tall by 20 in. diameter, John Wood JWHPCO-45 1**+JWXST-80 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support John Wood JWHPCO-45 1**+JWXST-80 1** during replacement?
Electrical specs for John Wood JWHPCO-45 1**+JWXST-80 1** call for 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for John Wood JWHPCO-45 1**+JWXST-80 1**?
At 18.16 cents/kWh national residential pricing, John Wood JWHPCO-45 1**+JWXST-80 1**'s 1,306 kWh/yr draw equals roughly $237 annually or $2,370 across a 10-year horizon (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii).
When is John Wood JWHPCO-45 1**+JWXST-80 1** a poor fit for a residential replacement?
Avoid placing John Wood JWHPCO-45 1**+JWXST-80 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does John Wood JWHPCO-45 1**+JWXST-80 1** deliver?
With 95 gal FHR (+23 gal vs. 72 gal median), John Wood JWHPCO-45 1**+JWXST-80 1** fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on John Wood JWHPCO-45 1**+JWXST-80 1**?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for John Wood; verify exact manufacturing week for John Wood JWHPCO-45 1**+JWXST-80 1** using the Serial Number Lookup tool.
Does John Wood JWHPCO-45 1**+JWXST-80 1** qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for John Wood JWHPCO-45 1**+JWXST-80 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)