Skip to main content
ENERGY STAR water heater model · PD 4529401

A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** Water Heater Specifications (3.8 UEF)

Certified at 3.8 UEF across its 73-gallon nominal tank, 95 gal First Hour Rating, A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** (Hybrid/Electric Heat Pump, Electric) places #268 of 706 out of 706 ENERGY STAR models (PD 4529401). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.30 / +52.0%. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American MHPCO-45 1**+MXST-80 1** (3.8 UEF).

Uniform Energy Factor
3.8 UEF
Cohort UEF Rank
#268 of 706 (top 41.9%)
First Hour Rating
95 gal
Storage Volume
73 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +52.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** at 3.8 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**: 3.80
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.8 UEF, A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** places #268 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.10 UEF vs. 3.70 UEF median).

A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.30 UEF (+52.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** include American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity) alongside Giant GTHPCO-45 1**+GTXST-80 1** (3.8 UEF, at parity).

How Do A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** places #268 of 706 (top 41.9%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4529401
Model NumberHPACO-45C 1**+AXST-80CTTP 1**Draw pattern: High-UsageHPACO-45C 1**+AXST-80CTTP 1**
Uniform Energy Factor (UEF)3.8+0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 gal+23 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,306 kWh/yr+234 kWh/yr vs. 1,072 kWh/yr medianEst. $237/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)58" H x 20" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States, Canada

What Does HPACO-45C 1**+AXST-80CTTP 1** Cost to Operate Across State Electricity Rates?

At 1,306 kWh/yr, A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** runs roughly $237/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,306 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$237.00/yrHawaii$616.00/yrCalifornia$389.00/yrTexas$208.00/yrWashington$191.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $237/yr $2,372 $7,424
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $616/yr $6,162 $19,287
California 29.75 ¢/kWh ($0.2975) $389/yr $3,885 $12,162
Texas 15.91 ¢/kWh ($0.1591) $208/yr $2,078 $6,504
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $191/yr $1,911 $5,981
Estimated electricity spend (1,306 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for A. O. Smith Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with A. O. Smith; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match HPACO-45C 1**+AXST-80CTTP 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** by storage capacity and 3.8 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American MHPCO-45 1**+MXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
Giant GTHPCO-45 1**+GTXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
GSW WATER HEATERS GHPCO-45 1**+GXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
John Wood JWHPCO-45 1**+JWXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306
American MHPCO-45 1**+MXST-80TTP 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (at parity) 1,306

Which Home Setups Are NOT a Fit for A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**?

Comparing A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** against American MHPCO-45 1**+MXST-80 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American MHPCO-45 1**+MXST-80 1** footprint.

What Are the Key Questions About A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** logs 3.8 UEF (Pass: +1.30 / +52.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**?

With a 58 in. height and 20 in. diameter, A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**?

Powered via 240V at 20.2A max, A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**?

Annual electric spend for A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** (1,306 kWh/yr) averages $237/yr nationwide (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**.

Is A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** at 95 gal First Hour Rating (+23 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does A. O. Smith have active CPSC SaferProducts notices affecting HPACO-45C 1**+AXST-80CTTP 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith HPACO-45C 1**+AXST-80CTTP 1** (3.8 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HPACO-45C 1**+AXST-80CTTP 1**. Closest peer in Hybrid/Electric Heat Pump is American MHPCO-45 1**+MXST-80 1** (3.8 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks