Skip to main content
ENERGY STAR water heater model · PD 3417480

A. O. Smith HPTA-40 2** Water Heater Specifications (3.6 UEF)

The A. O. Smith HPTA-40 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.6 UEF rating across its 36-gallon nominal tank, 55 gal First Hour Rating, ranking #401 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3417480). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.30 / +56.5%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPA10240H045DV 2** (3.6 UEF).

Uniform Energy Factor
3.6 UEF
Cohort UEF Rank
#401 of 706
First Hour Rating
55 gal
Storage Volume
36 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.30 / +56.5%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPTA-40 2** at 3.6 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith HPTA-40 2**: 3.60
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPTA-40 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPTA-40 2** (3.6 UEF) ranks #401 of 706 Hybrid/Electric Heat Pump models — 9-way tie; more efficient than 42.1% of Hybrid/Electric Heat Pump models, -0.10 UEF below the 3.70 UEF median.

Federal 2029 margin for A. O. Smith HPTA-40 2**: +1.30 UEF (+56.5%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for A. O. Smith HPTA-40 2** runs ~$164/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPTA-40 2**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: A. O. Smith HPTA-40 2** (3.6 UEF) compares closely with American HPA10240H045DV 2** (3.6 UEF, at parity) and Lochinvar CHPA-40 2** (3.6 UEF, at parity).

How Complete Are the Certified Metrics for A. O. Smith HPTA-40 2**?

Standing at #401 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, A. O. Smith HPTA-40 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 3417480
Model NumberHPTA-40 2**Draw pattern: Medium-UsageHPTA-40 2**
Uniform Energy Factor (UEF)3.6-0.10 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)55 gal-17 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency426%-3.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)66" H x 20" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (20" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2025-12-12Certified 2025-12-12Markets: United States

What Is the Projected Utility Bill for HPTA-40 2** by State?

At 902 kWh/yr, A. O. Smith HPTA-40 2** averages about $164/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,772
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $12,399
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,818
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $4,181
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,845
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to HPTA-40 2**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith HPTA-40 2**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPA10240H045DV 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
Lochinvar CHPA-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
RELIANCE WATER HEATERS 10-40-DHPTA 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
State CSHP-40 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902
Lochinvar HPPA040KD 2** Hybrid/Electric Heat Pump 36 gal 55 gal 3.6 (at parity) 902

Which Home Setups Are NOT a Fit for A. O. Smith HPTA-40 2**?

Comparing A. O. Smith HPTA-40 2** against American HPA10240H045DV 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • A. O. Smith HPTA-40 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPTA-40 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPTA-40 2** Strong Fit — 3.6 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPA10240H045DV 2** footprint.

Practical Specs & Code Questions for A. O. Smith HPTA-40 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith HPTA-40 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith HPTA-40 2** logs 3.6 UEF (Pass: +1.30 / +56.5%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing A. O. Smith HPTA-40 2**?

With a 66 in. height and 20 in. diameter, A. O. Smith HPTA-40 2** fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (20" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith HPTA-40 2**?

Powered via 240V at 22A max, A. O. Smith HPTA-40 2** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for A. O. Smith HPTA-40 2**?

Annual electric spend for A. O. Smith HPTA-40 2** (902 kWh/yr) averages $164/yr nationwide (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing A. O. Smith HPTA-40 2**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on A. O. Smith HPTA-40 2**.

Is A. O. Smith HPTA-40 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies A. O. Smith HPTA-40 2** at 55 gal First Hour Rating (-17 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does A. O. Smith have active CPSC SaferProducts notices affecting HPTA-40 2**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith HPTA-40 2** (3.6 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith HPTA-40 2**. Closest peer in Hybrid/Electric Heat Pump is American HPA10240H045DV 2** (3.6 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks