Skip to main content
ENERGY STAR water heater model · PD 3626854

ACIQ ACIQ-50G-HP-WH Water Heater Specifications (3.75 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, ACIQ ACIQ-50G-HP-WH (Electric) achieves a certified 3.75 UEF rating across its 47-gallon nominal tank, 69 gal First Hour Rating (rank #297 of 706, PD 3626854) and verifies as Pass: +1.45 / +63.0% for 2029 DOE floors. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
69 gal
Storage Volume
47 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking ACIQ ACIQ-50G-HP-WH at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30ACIQ ACIQ-50G-HP-WH: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows ACIQ ACIQ-50G-HP-WH relative to the cohort median.
Efficiency comparison & rule summary

ACIQ ACIQ-50G-HP-WH records 3.75 UEF efficiency, putting it #297 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: ACIQ ACIQ-50G-HP-WH exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0%). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for ACIQ ACIQ-50G-HP-WH runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for ACIQ ACIQ-50G-HP-WH: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside ACIQ ACIQ-50G-HP-WH (3.75 UEF) are 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) and Bosch TR7000T - 50CA (3.75 UEF, at parity).

What Physical and Thermal Ratings Define ACIQ ACIQ-50G-HP-WH?

Positioning at #297 of 706 out of 706 Hybrid/Electric Heat Pump peers, ACIQ ACIQ-50G-HP-WH pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandACIQ2 certified listingsENERGY STAR PD 3626854
Model NumberACIQ-50G-HP-WHDraw pattern: Medium-UsageACIQ-50G-HP-WH
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)69 gal-3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use855 kWh/yr-217 kWh/yr vs. 1,072 kWh/yr medianEst. $155/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.9" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-11Certified 2024-11-11Markets: United States, Canada

Why Do State Utility Rates Shift ACIQ-50G-HP-WH Running Costs?

Consuming 855 kWh annually puts ACIQ ACIQ-50G-HP-WH near $155/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (855 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$155.00/yrHawaii$403.00/yrCalifornia$254.00/yrTexas$136.00/yrWashington$125.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $155/yr $1,553 $4,776
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $403/yr $4,034 $12,408
California 29.75 ¢/kWh ($0.2975) $254/yr $2,544 $7,824
Texas 15.91 ¢/kWh ($0.1591) $136/yr $1,360 $4,184
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $125/yr $1,251 $3,848
Estimated electricity spend (855 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any ACIQ Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for ACIQ; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to ACIQ ACIQ-50G-HP-WH?

Homeowners cross-shopping ACIQ ACIQ-50G-HP-WH frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50CA Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Custom Comfort CCOHPWH50A Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
DIYCOOL ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50US Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855

When Should Homeowners Skip ACIQ ACIQ-50G-HP-WH (Hybrid/Electric Heat Pump)?

Check ACIQ ACIQ-50G-HP-WH's mechanical constraints—including utility space, Electric capacity, and Pass: +1.45 / +63.0% status—against typical residential installations.

Key Limitations & Exclusions

  • ACIQ ACIQ-50G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting ACIQ ACIQ-50G-HP-WH directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing ACIQ ACIQ-50G-HP-WH Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-50G-HP-WH footprint.

Sizing, Efficiency & Recall Answers for ACIQ ACIQ-50G-HP-WH

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will ACIQ ACIQ-50G-HP-WH stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.75 UEF, ACIQ ACIQ-50G-HP-WH shows Pass: +1.45 / +63.0% relative to May 6, 2029 federal DOE limits while placing #297 of 706 among 706 Hybrid/Electric Heat Pump peers like 1HVAC ACIQ-50G-HP-WH.

Will ACIQ ACIQ-50G-HP-WH fit through a standard utility door and 72-inch basement ceiling?

Measuring 47.9 in. tall by 18.3 in. diameter, ACIQ ACIQ-50G-HP-WH notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support ACIQ ACIQ-50G-HP-WH during replacement?

Electrical specs for ACIQ ACIQ-50G-HP-WH call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for ACIQ ACIQ-50G-HP-WH?

At 18.16 cents/kWh national residential pricing, ACIQ ACIQ-50G-HP-WH's 855 kWh/yr draw equals roughly $155 annually or $1,550 across a 10-year horizon (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii).

When is ACIQ ACIQ-50G-HP-WH a poor fit for a residential replacement?

Avoid placing ACIQ ACIQ-50G-HP-WH directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does ACIQ ACIQ-50G-HP-WH deliver?

With 69 gal FHR (-3 gal vs. 72 gal median), ACIQ ACIQ-50G-HP-WH fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on ACIQ ACIQ-50G-HP-WH?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for ACIQ; verify exact manufacturing week for ACIQ ACIQ-50G-HP-WH using the Serial Number Lookup tool.

Does ACIQ ACIQ-50G-HP-WH qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for ACIQ ACIQ-50G-HP-WH. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks