ACIQ ACIQ-50G-HP-WH Water Heater Specifications (3.75 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, ACIQ ACIQ-50G-HP-WH (Electric) achieves a certified 3.75 UEF rating across its 47-gallon nominal tank, 69 gal First Hour Rating (rank #297 of 706, PD 3626854) and verifies as Pass: +1.45 / +63.0% for 2029 DOE floors. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 69 gal
- Storage Volume
- 47 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

ACIQ ACIQ-50G-HP-WH records 3.75 UEF efficiency, putting it #297 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: ACIQ ACIQ-50G-HP-WH exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0%). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for ACIQ ACIQ-50G-HP-WH runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for ACIQ ACIQ-50G-HP-WH: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside ACIQ ACIQ-50G-HP-WH (3.75 UEF) are 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) and Bosch TR7000T - 50CA (3.75 UEF, at parity).
What Physical and Thermal Ratings Define ACIQ ACIQ-50G-HP-WH?
Positioning at #297 of 706 out of 706 Hybrid/Electric Heat Pump peers, ACIQ ACIQ-50G-HP-WH pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | ACIQ | 2 certified listings | ENERGY STAR PD 3626854 |
| Model Number | ACIQ-50G-HP-WH | Draw pattern: Medium-Usage | ACIQ-50G-HP-WH |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 69 gal | -3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 855 kWh/yr | -217 kWh/yr vs. 1,072 kWh/yr median | Est. $155/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.9" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-11 | Certified 2024-11-11 | Markets: United States, Canada |
Why Do State Utility Rates Shift ACIQ-50G-HP-WH Running Costs?
Consuming 855 kWh annually puts ACIQ ACIQ-50G-HP-WH near $155/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $155/yr | $1,553 | $4,776 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $403/yr | $4,034 | $12,408 |
| California | 29.75 ¢/kWh ($0.2975) | $254/yr | $2,544 | $7,824 |
| Texas | 15.91 ¢/kWh ($0.1591) | $136/yr | $1,360 | $4,184 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $125/yr | $1,251 | $3,848 |
Have Any ACIQ Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for ACIQ; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to ACIQ ACIQ-50G-HP-WH?
Homeowners cross-shopping ACIQ ACIQ-50G-HP-WH frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| 1HVAC ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50CA | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Custom Comfort CCOHPWH50A | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| DIYCOOL ACIQ-50G-HP-WH | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
| Bosch TR7000T - 50US | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (at parity) | 855 |
When Should Homeowners Skip ACIQ ACIQ-50G-HP-WH (Hybrid/Electric Heat Pump)?
Check ACIQ ACIQ-50G-HP-WH's mechanical constraints—including utility space, Electric capacity, and Pass: +1.45 / +63.0% status—against typical residential installations.
Key Limitations & Exclusions
- ACIQ ACIQ-50G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting ACIQ ACIQ-50G-HP-WH directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for ACIQ ACIQ-50G-HP-WH
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will ACIQ ACIQ-50G-HP-WH stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.75 UEF, ACIQ ACIQ-50G-HP-WH shows Pass: +1.45 / +63.0% relative to May 6, 2029 federal DOE limits while placing #297 of 706 among 706 Hybrid/Electric Heat Pump peers like 1HVAC ACIQ-50G-HP-WH.
Will ACIQ ACIQ-50G-HP-WH fit through a standard utility door and 72-inch basement ceiling?
Measuring 47.9 in. tall by 18.3 in. diameter, ACIQ ACIQ-50G-HP-WH notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support ACIQ ACIQ-50G-HP-WH during replacement?
Electrical specs for ACIQ ACIQ-50G-HP-WH call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for ACIQ ACIQ-50G-HP-WH?
At 18.16 cents/kWh national residential pricing, ACIQ ACIQ-50G-HP-WH's 855 kWh/yr draw equals roughly $155 annually or $1,550 across a 10-year horizon (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii).
When is ACIQ ACIQ-50G-HP-WH a poor fit for a residential replacement?
Avoid placing ACIQ ACIQ-50G-HP-WH directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does ACIQ ACIQ-50G-HP-WH deliver?
With 69 gal FHR (-3 gal vs. 72 gal median), ACIQ ACIQ-50G-HP-WH fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on ACIQ ACIQ-50G-HP-WH?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for ACIQ; verify exact manufacturing week for ACIQ ACIQ-50G-HP-WH using the Serial Number Lookup tool.
Does ACIQ ACIQ-50G-HP-WH qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for ACIQ ACIQ-50G-HP-WH. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)