Skip to main content
ENERGY STAR water heater model · PD 3626846

DIYCOOL ACIQ-50G-HP-WH Water Heater Specifications (3.75 UEF)

Certified at 3.75 UEF across its 47-gallon nominal tank, 69 gal First Hour Rating, DIYCOOL ACIQ-50G-HP-WH (Hybrid/Electric Heat Pump, Electric) places #297 of 706 out of 706 ENERGY STAR models (PD 3626846). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.45 / +63.0%. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
69 gal
Storage Volume
47 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking DIYCOOL ACIQ-50G-HP-WH at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30DIYCOOL ACIQ-50G-HP-WH: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows DIYCOOL ACIQ-50G-HP-WH relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.75 UEF, DIYCOOL ACIQ-50G-HP-WH places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.05 UEF vs. 3.70 UEF median).

DIYCOOL ACIQ-50G-HP-WH clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for DIYCOOL ACIQ-50G-HP-WH runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for DIYCOOL ACIQ-50G-HP-WH: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to DIYCOOL ACIQ-50G-HP-WH include 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) alongside ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity).

Which Specs Set DIYCOOL ACIQ-50G-HP-WH Apart From Cohort Averages?

Ranked #297 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, DIYCOOL ACIQ-50G-HP-WH is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandDIYCOOL2 certified listingsENERGY STAR PD 3626846
Model NumberACIQ-50G-HP-WHDraw pattern: Medium-UsageACIQ-50G-HP-WH
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)69 gal-3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use855 kWh/yr-217 kWh/yr vs. 1,072 kWh/yr medianEst. $155/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.9" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-11-11Certified 2024-11-11Markets: United States, Canada

How Do Regional kWh Prices Impact ACIQ-50G-HP-WH Over 10 Years?

Using EIA Table 5.6.A benchmarks, DIYCOOL ACIQ-50G-HP-WH's 855 kWh/yr draw translates to roughly $155/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (855 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$155.00/yrHawaii$403.00/yrCalifornia$254.00/yrTexas$136.00/yrWashington$125.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $155/yr $1,553 $4,776
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $403/yr $4,034 $12,408
California 29.75 ¢/kWh ($0.2975) $254/yr $2,544 $7,824
Texas 15.91 ¢/kWh ($0.1591) $136/yr $1,360 $4,184
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $125/yr $1,251 $3,848
Estimated electricity spend (855 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should DIYCOOL Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for DIYCOOL; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
ACIQ ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50CA Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Custom Comfort CCOHPWH50A Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Bosch TR7000T - 50US Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855

What Are the Limitations of DIYCOOL ACIQ-50G-HP-WH and Who Should Not Install It?

Before ordering DIYCOOL ACIQ-50G-HP-WH (Hybrid/Electric Heat Pump, 3.75 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • DIYCOOL ACIQ-50G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting DIYCOOL ACIQ-50G-HP-WH directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing DIYCOOL ACIQ-50G-HP-WH Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-50G-HP-WH footprint.

Frequently Asked Technical Questions: DIYCOOL ACIQ-50G-HP-WH

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does DIYCOOL ACIQ-50G-HP-WH pass the May 6, 2029 federal DOE efficiency rule?

DIYCOOL ACIQ-50G-HP-WH carries a verified 3.75 UEF rating (Pass: +1.45 / +63.0%), ranking #297 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does DIYCOOL ACIQ-50G-HP-WH need?

DIYCOOL ACIQ-50G-HP-WH stands 47.9 in. high with a 18.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does DIYCOOL ACIQ-50G-HP-WH require?

DIYCOOL ACIQ-50G-HP-WH uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does DIYCOOL ACIQ-50G-HP-WH cost per year to run?

Rated at 855 kWh/yr, DIYCOOL ACIQ-50G-HP-WH costs about $155/yr ($1,550 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii).

Who should NOT install DIYCOOL ACIQ-50G-HP-WH, and what are its limits?

DIYCOOL ACIQ-50G-HP-WH (3.75 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can DIYCOOL ACIQ-50G-HP-WH serve at peak demand?

DIYCOOL ACIQ-50G-HP-WH achieves a 69 gal First Hour Rating (-3 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for DIYCOOL ACIQ-50G-HP-WH?

No active CPSC recalls matched DIYCOOL as of 2026-11-23. Always decode the serial tag on DIYCOOL ACIQ-50G-HP-WH because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to DIYCOOL ACIQ-50G-HP-WH, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks