Skip to main content
ENERGY STAR water heater model · PD 3626856

Bosch TR7000T - 50US Water Heater Specifications (3.75 UEF)

Certified at 3.75 UEF across its 47-gallon nominal tank, 69 gal First Hour Rating, Bosch TR7000T - 50US (Hybrid/Electric Heat Pump, Electric) places #297 of 706 out of 706 ENERGY STAR models (PD 3626856). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.45 / +63.0%. Rated annual electricity draw of 855 kWh/yr equates to roughly $155/yr ($1,553 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-50G-HP-WH (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
69 gal
Storage Volume
47 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Bosch TR7000T - 50US at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Bosch TR7000T - 50US: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Bosch TR7000T - 50US relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.75 UEF, Bosch TR7000T - 50US places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.05 UEF vs. 3.70 UEF median).

Bosch TR7000T - 50US clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 855 kWh/yr for Bosch TR7000T - 50US runs ~$155/yr vs. ~$633/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Bosch TR7000T - 50US: 10-year operating spend spans $1,251 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Bosch TR7000T - 50US include 1HVAC ACIQ-50G-HP-WH (3.75 UEF, at parity) alongside ACIQ ACIQ-50G-HP-WH (3.75 UEF, at parity).

Where Does Bosch TR7000T - 50US Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Bosch TR7000T - 50US holds #297 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandBosch12 certified listingsENERGY STAR PD 3626856
Model NumberTR7000T - 50USDraw pattern: Medium-UsageTR7000T - 50US
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)69 gal-3 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use855 kWh/yr-217 kWh/yr vs. 1,072 kWh/yr medianEst. $155/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)47.9" H x 18.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2024-12-17Certified 2024-12-17Markets: United States

How Much Electricity Does TR7000T - 50US Use in Different States?

Estimated at $155/yr nationally (855 kWh/yr), 10-year utility spending for Bosch TR7000T - 50US shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (855 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$155.00/yrHawaii$403.00/yrCalifornia$254.00/yrTexas$136.00/yrWashington$125.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $155/yr $1,553 $4,776
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $403/yr $4,034 $12,408
California 29.75 ¢/kWh ($0.2975) $254/yr $2,544 $7,824
Texas 15.91 ¢/kWh ($0.1591) $136/yr $1,360 $4,184
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $125/yr $1,251 $3,848
Estimated electricity spend (855 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Bosch Units?

No open CPSC recall alerts appeared for Bosch as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to TR7000T - 50US?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Bosch TR7000T - 50US's gallon capacity and 3.75 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
1HVAC ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
ACIQ ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Custom Comfort CCOHPWH50A Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
DIYCOOL ACIQ-50G-HP-WH Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855
Eco-Logical ECO-50HPM1A Hybrid/Electric Heat Pump 47 gal 69 gal 3.75 (at parity) 855

Who Is Bosch TR7000T - 50US Best For — and When Should You Pick 1HVAC ACIQ-50G-HP-WH?

Evaluate whether Bosch TR7000T - 50US's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Bosch TR7000T - 50US needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Bosch TR7000T - 50US directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Bosch TR7000T - 50US Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare 1HVAC ACIQ-50G-HP-WH footprint.

Common Homeowner Questions for Bosch TR7000T - 50US

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Bosch TR7000T - 50US (3.75 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Bosch TR7000T - 50US records 3.75 UEF (Pass: +1.45 / +63.0%), placing #297 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Bosch TR7000T - 50US fit inside a tight hallway closet or low-headroom utility room?

Bosch TR7000T - 50US requires room for its 47.9 in. vertical shell and 18.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Bosch TR7000T - 50US?

For Bosch TR7000T - 50US, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Bosch TR7000T - 50US?

Using 855 kWh/yr, Bosch TR7000T - 50US generates an estimated $155/yr electric bill at 18.16 cents/kWh (ranging from $125/yr in Washington hydro tiers up to $403/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Bosch TR7000T - 50US (3.75 UEF)?

Bosch TR7000T - 50US requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or 1HVAC ACIQ-50G-HP-WH.

What hot-water delivery rating governs Bosch TR7000T - 50US?

Rated for 69 gal FHR (-3 gal vs. 72 gal median), Bosch TR7000T - 50US prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Bosch TR7000T - 50US for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Bosch; use our browser-only serial decoder to inspect Bosch TR7000T - 50US's age and warranty window.

What alternative models sit closest to Bosch TR7000T - 50US in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-50G-HP-WH (3.75 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks