AMERICAN STANDARD WATER HEATERS ASHPWH-50***** Water Heater Specifications (3.75 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, AMERICAN STANDARD WATER HEATERS ASHPWH-50***** achieves a certified 3.75 UEF rating across its 45-gallon nominal tank, 68 gal First Hour Rating and ranks #297 of 706 in its 706-model cohort (PD 2408487), recording Pass: +1.45 / +63.0% under 2029 DOE rules. Rated annual electricity draw of 867 kWh/yr equates to roughly $157/yr ($1,574 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-50 (3.75 UEF).
- Uniform Energy Factor
- 3.75 UEF
- Cohort UEF Rank
- #297 of 706
- First Hour Rating
- 68 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.45 / +63.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-50***** logs 3.75 UEF and ranks #297 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), AMERICAN STANDARD WATER HEATERS ASHPWH-50***** holds a +1.45 UEF (+63.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 867 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-50***** runs ~$157/yr vs. ~$642/yr for a 0.92 UEF electric tank.
State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-50*****: 10-year operating spend spans $1,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,091 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping AMERICAN STANDARD WATER HEATERS ASHPWH-50***** (3.75 UEF)? Check Ariston ARIHPWH-50 (3.75 UEF, at parity) and Friedrich PROH50 T2 FD400-15 (3.75 UEF, at parity).
Where Does AMERICAN STANDARD WATER HEATERS ASHPWH-50***** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, AMERICAN STANDARD WATER HEATERS ASHPWH-50***** holds #297 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | AMERICAN STANDARD WATER HEATERS | 4 certified listings | ENERGY STAR PD 2408487 |
| Model Number | ASHPWH-50***** | Draw pattern: Medium-Usage | ASHPWH-50***** |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 68 gal | -4 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 867 kWh/yr | -205 kWh/yr vs. 1,072 kWh/yr median | Est. $157/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.8" H x 18.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-04 | Certified 2026-02-04 | Markets: United States, Canada |
How Much Electricity Does ASHPWH-50***** Use in Different States?
Estimated at $157/yr nationally (867 kWh/yr), 10-year utility spending for AMERICAN STANDARD WATER HEATERS ASHPWH-50***** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $157/yr | $1,574 | $4,843 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $409/yr | $4,091 | $12,583 |
| California | 29.75 ¢/kWh ($0.2975) | $258/yr | $2,579 | $7,934 |
| Texas | 15.91 ¢/kWh ($0.1591) | $138/yr | $1,379 | $4,243 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $127/yr | $1,268 | $3,902 |
Does CPSC Flag Any Safety Notices on AMERICAN STANDARD WATER HEATERS Units?
Checking 2026-11-23 SaferProducts data shows 2 notices mentioning AMERICAN STANDARD WATER HEATERS; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ASHPWH-50*****?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to AMERICAN STANDARD WATER HEATERS ASHPWH-50*****'s gallon capacity and 3.75 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Ariston ARIHPWH-50 | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.75 (at parity) | 867 |
| Friedrich PROH50 T2 FD400-15 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| Rheem CPROPH50 T2 RH400-15 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| Richmond 10CE50-HP5U15 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
| Rheem CXE50T10H22U1 | Hybrid/Electric Heat Pump | 45 gal | 52 gal | 3.75 (at parity) | 846 |
What Are the Limitations of AMERICAN STANDARD WATER HEATERS ASHPWH-50***** and Who Should Not Install It?
Before ordering AMERICAN STANDARD WATER HEATERS ASHPWH-50***** (Hybrid/Electric Heat Pump, 3.75 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- AMERICAN STANDARD WATER HEATERS ASHPWH-50***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-50***** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for AMERICAN STANDARD WATER HEATERS ASHPWH-50*****
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does AMERICAN STANDARD WATER HEATERS ASHPWH-50***** pass the May 6, 2029 federal DOE efficiency rule?
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** carries a verified 3.75 UEF rating (Pass: +1.45 / +63.0%), ranking #297 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does AMERICAN STANDARD WATER HEATERS ASHPWH-50***** need?
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** stands 45.8 in. high with a 18.2 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.2" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does AMERICAN STANDARD WATER HEATERS ASHPWH-50***** require?
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does AMERICAN STANDARD WATER HEATERS ASHPWH-50***** cost per year to run?
Rated at 867 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-50***** costs about $157/yr ($1,570 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $127/yr in Washington hydro tiers up to $409/yr in Hawaii).
Who should NOT install AMERICAN STANDARD WATER HEATERS ASHPWH-50*****, and what are its limits?
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** (3.75 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can AMERICAN STANDARD WATER HEATERS ASHPWH-50***** serve at peak demand?
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** achieves a 68 gal First Hour Rating (-4 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for AMERICAN STANDARD WATER HEATERS ASHPWH-50*****?
CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to AMERICAN STANDARD WATER HEATERS ASHPWH-50*****, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-50 (3.75 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)