Skip to main content
ENERGY STAR water heater model · PD 4572775

Richmond 10CE50-HP5U15 Water Heater Specifications (3.75 UEF)

The Richmond 10CE50-HP5U15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 45-gallon nominal tank, 52 gal First Hour Rating, ranking #297 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4572775). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.45 / +63.0%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-15 (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
52 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Richmond 10CE50-HP5U15 at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Richmond 10CE50-HP5U15: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Richmond 10CE50-HP5U15 relative to the cohort median.
Efficiency comparison & rule summary

Richmond 10CE50-HP5U15 (3.75 UEF) ranks #297 of 706 Hybrid/Electric Heat Pump models — 48-way tie; more efficient than 51.3% of Hybrid/Electric Heat Pump models, +0.05 UEF above the 3.70 UEF median.

Federal 2029 margin for Richmond 10CE50-HP5U15: +1.45 UEF (+63.0%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Richmond 10CE50-HP5U15 runs ~$154/yr vs. ~$626/yr for a 0.92 UEF electric tank.

State electric sensitivity for Richmond 10CE50-HP5U15: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Richmond 10CE50-HP5U15 (3.75 UEF) compares closely with Friedrich PROH50 T2 FD400-15 (3.75 UEF, at parity) and Rheem CPROPH50 T2 RH400-15 (3.75 UEF, at parity).

What Physical and Thermal Ratings Define Richmond 10CE50-HP5U15?

Positioning at #297 of 706 out of 706 Hybrid/Electric Heat Pump peers, Richmond 10CE50-HP5U15 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 4572775
Model Number10CE50-HP5U15Draw pattern: Medium-Usage10CE50-HP5U15
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)52 gal-20 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use846 kWh/yr-226 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: Canada

Why Do State Utility Rates Shift 10CE50-HP5U15 Running Costs?

Consuming 846 kWh annually puts Richmond 10CE50-HP5U15 near $154/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (846 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$399.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,536 $4,725
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $399/yr $3,991 $12,276
California 29.75 ¢/kWh ($0.2975) $252/yr $2,517 $7,741
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,346 $4,140
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,238 $3,807
Estimated electricity spend (846 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Richmond Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Richmond; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Richmond 10CE50-HP5U15?

Homeowners cross-shopping Richmond 10CE50-HP5U15 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD400-15 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846
Rheem CPROPH50 T2 RH400-15 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846
Ruud PROUH50 T2 CD400-15 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** Hybrid/Electric Heat Pump 45 gal 68 gal 3.75 (at parity) 867
Rheem CXE50T10H22U1 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846

What Installation Caveats Apply Before Buying Richmond 10CE50-HP5U15?

Even high-UEF units like Richmond 10CE50-HP5U15 (3.75 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Richmond 10CE50-HP5U15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Richmond 10CE50-HP5U15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Richmond 10CE50-HP5U15 Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-15 footprint.

Sizing, Efficiency & Recall Answers for Richmond 10CE50-HP5U15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Richmond 10CE50-HP5U15 eligible for continued manufacture past May 6, 2029?

At 3.75 UEF, Richmond 10CE50-HP5U15 achieves Pass: +1.45 / +63.0% for the 2029 DOE standard and stands #297 of 706 against Friedrich PROH50 T2 FD400-15 and Rheem CPROPH50 T2 RH400-15.

How tall and wide is Richmond 10CE50-HP5U15, and what service clearance is needed?

Physical dimensions for Richmond 10CE50-HP5U15 are 61.8 in. height and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)); verify stair turns and drain pan width before delivery.

Will Richmond 10CE50-HP5U15 require upgrading household electrical panels or gas piping?

Richmond 10CE50-HP5U15 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Richmond 10CE50-HP5U15 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $154/yr ($1,540 over 10 years) to power Richmond 10CE50-HP5U15 at 846 kWh/yr under the 18.16 cents/kWh US average (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).

Which installation bottlenecks limit Richmond 10CE50-HP5U15?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Richmond 10CE50-HP5U15 drops into resistance mode more often.

How does Richmond 10CE50-HP5U15 handle simultaneous showers and laundry?

Delivering 52 gal in the first hour (-20 gal vs. 72 gal median), Richmond 10CE50-HP5U15 combines 45 gal tank storage with rapid burner/element recovery.

How long is the warranty on Richmond 10CE50-HP5U15 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Richmond as of 2026-11-23. Confirm install proof and serial manufacture year on Richmond 10CE50-HP5U15 before calling service.

How do 2026 post-OBBBA rebates affect buying Richmond 10CE50-HP5U15?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-15 (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks