Skip to main content
ENERGY STAR water heater model · PD 3554193

Rheem CPROPH50 T2 RH400-15 Water Heater Specifications (3.75 UEF)

With PD 3554193 certification, Rheem CPROPH50 T2 RH400-15 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.75 UEF rating across its 45-gallon nominal tank, 52 gal First Hour Rating, standing #297 of 706 across 706 peers with Pass: +1.45 / +63.0% for May 6, 2029. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-15 (3.75 UEF).

Uniform Energy Factor
3.75 UEF
Cohort UEF Rank
#297 of 706
First Hour Rating
52 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.45 / +63.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Rheem CPROPH50 T2 RH400-15 at 3.75 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Rheem CPROPH50 T2 RH400-15: 3.75
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CPROPH50 T2 RH400-15 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Rheem CPROPH50 T2 RH400-15 at 3.75 UEF (#297 of 706; +0.05 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Rheem CPROPH50 T2 RH400-15 stands +1.45 UEF (+63.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Rheem CPROPH50 T2 RH400-15 runs ~$154/yr vs. ~$626/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CPROPH50 T2 RH400-15: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T2 FD400-15 (3.75 UEF, at parity) and Richmond 10CE50-HP5U15 (3.75 UEF, at parity) bracket Rheem CPROPH50 T2 RH400-15.

Where Does Rheem CPROPH50 T2 RH400-15 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem CPROPH50 T2 RH400-15 holds #297 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3554193
Model NumberCPROPH50 T2 RH400-15Draw pattern: Medium-UsageCPROPH50 T2 RH400-15
Uniform Energy Factor (UEF)3.75+0.05 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)52 gal-20 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use846 kWh/yr-226 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency423%-6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 12 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: Canada

How Much Electricity Does CPROPH50 T2 RH400-15 Use in Different States?

Estimated at $154/yr nationally (846 kWh/yr), 10-year utility spending for Rheem CPROPH50 T2 RH400-15 shifts sharply between low-rate hydro and coastal grids.

Estimated Annual Electricity Cost by State Rate (846 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$399.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,536 $4,725
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $399/yr $3,991 $12,276
California 29.75 ¢/kWh ($0.2975) $252/yr $2,517 $7,741
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,346 $4,140
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,238 $3,807
Estimated electricity spend (846 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Hybrid/Electric Heat Pump Models Compare Closest to CPROPH50 T2 RH400-15?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem CPROPH50 T2 RH400-15's gallon capacity and 3.75 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH50 T2 FD400-15 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846
Richmond 10CE50-HP5U15 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846
Ruud PROUH50 T2 CD400-15 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846
AMERICAN STANDARD WATER HEATERS ASHPWH-50***** Hybrid/Electric Heat Pump 45 gal 68 gal 3.75 (at parity) 867
Richmond 10E50-HP515 Hybrid/Electric Heat Pump 45 gal 52 gal 3.75 (at parity) 846

What Installation Caveats Apply Before Buying Rheem CPROPH50 T2 RH400-15?

Even high-UEF units like Rheem CPROPH50 T2 RH400-15 (3.75 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Rheem CPROPH50 T2 RH400-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Rheem CPROPH50 T2 RH400-15 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Rheem CPROPH50 T2 RH400-15 Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-15 footprint.

Common Homeowner Questions for Rheem CPROPH50 T2 RH400-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Rheem CPROPH50 T2 RH400-15 eligible for continued manufacture past May 6, 2029?

At 3.75 UEF, Rheem CPROPH50 T2 RH400-15 achieves Pass: +1.45 / +63.0% for the 2029 DOE standard and stands #297 of 706 against Friedrich PROH50 T2 FD400-15 and Richmond 10CE50-HP5U15.

How tall and wide is Rheem CPROPH50 T2 RH400-15, and what service clearance is needed?

Physical dimensions for Rheem CPROPH50 T2 RH400-15 are 61.8 in. height and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)); verify stair turns and drain pan width before delivery.

Will Rheem CPROPH50 T2 RH400-15 require upgrading household electrical panels or gas piping?

Rheem CPROPH50 T2 RH400-15 draws 240V at 12A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Rheem CPROPH50 T2 RH400-15 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $154/yr ($1,540 over 10 years) to power Rheem CPROPH50 T2 RH400-15 at 846 kWh/yr under the 18.16 cents/kWh US average (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).

Which installation bottlenecks limit Rheem CPROPH50 T2 RH400-15?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem CPROPH50 T2 RH400-15 drops into resistance mode more often.

How does Rheem CPROPH50 T2 RH400-15 handle simultaneous showers and laundry?

Delivering 52 gal in the first hour (-20 gal vs. 72 gal median), Rheem CPROPH50 T2 RH400-15 combines 45 gal tank storage with rapid burner/element recovery.

How long is the warranty on Rheem CPROPH50 T2 RH400-15 and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Rheem CPROPH50 T2 RH400-15?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-15 (3.75 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks