Skip to main content
ENERGY STAR water heater model · PD 2408486

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** Water Heater Specifications (4.01 UEF)

Certified at 4.01 UEF across its 73-gallon nominal tank, 87 gal First Hour Rating, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (Hybrid/Electric Heat Pump, Electric) places #104 of 706 out of 706 ENERGY STAR models (PD 2408486). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.51 / +60.4%. Rated annual electricity draw of 1,238 kWh/yr equates to roughly $225/yr ($2,248 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-80 (4.01 UEF).

Uniform Energy Factor
4.01 UEF
Cohort UEF Rank
#104 of 706 (top 14.9%)
First Hour Rating
87 gal
Storage Volume
73 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.51 / +60.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking AMERICAN STANDARD WATER HEATERS ASHPWH-80***** at 4.01 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50AMERICAN STANDARD WATER HEATERS ASHPWH-80*****: 4.01
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows AMERICAN STANDARD WATER HEATERS ASHPWH-80***** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 4.01 UEF, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** places #104 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.31 UEF vs. 3.70 UEF median).

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.51 UEF (+60.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,238 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-80***** runs ~$225/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-80*****: 10-year operating spend spans $1,811 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,841 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to AMERICAN STANDARD WATER HEATERS ASHPWH-80***** include Ariston ARIHPWH-80 (4.01 UEF, at parity) alongside A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, delta -0.21).

Which Specs Set AMERICAN STANDARD WATER HEATERS ASHPWH-80***** Apart From Cohort Averages?

Ranked #104 of 706 (top 14.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAMERICAN STANDARD WATER HEATERS4 certified listingsENERGY STAR PD 2408486
Model NumberASHPWH-80*****Draw pattern: High-UsageASHPWH-80*****
Uniform Energy Factor (UEF)4.01+0.31 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,238 kWh/yr+166 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency443%+14.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)59.1" H x 20.2" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-02-04Certified 2026-02-04Markets: United States, Canada

How Do Regional kWh Prices Impact ASHPWH-80***** Over 10 Years?

Using EIA Table 5.6.A benchmarks, AMERICAN STANDARD WATER HEATERS ASHPWH-80*****'s 1,238 kWh/yr draw translates to roughly $225/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,238 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$584.00/yrCalifornia$368.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,248 $7,551
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $584/yr $5,841 $19,617
California 29.75 ¢/kWh ($0.2975) $368/yr $3,683 $12,370
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,970 $6,615
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,811 $6,083
Estimated electricity spend (1,238 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should AMERICAN STANDARD WATER HEATERS Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to AMERICAN STANDARD WATER HEATERS; verify whether your ASHPWH-80***** production run falls inside affected ranges. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-80 Hybrid/Electric Heat Pump 73 gal 87 gal 4.01 (at parity) 1,238
A. O. Smith HPACO-45 1**+AXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306
American MHPCO-45 1**+MXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306
Giant GTHPCO-45 1**+GTXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306
A. O. Smith HPACO-45 1**+AXST-80TTP 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306

What Are the Limitations of AMERICAN STANDARD WATER HEATERS ASHPWH-80***** and Who Should Not Install It?

Before ordering AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (Hybrid/Electric Heat Pump, 4.01 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • AMERICAN STANDARD WATER HEATERS ASHPWH-80***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-80***** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing AMERICAN STANDARD WATER HEATERS ASHPWH-80***** Strong Fit — 4.01 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-80 footprint.

Frequently Asked Technical Questions: AMERICAN STANDARD WATER HEATERS ASHPWH-80*****

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** pass the May 6, 2029 federal DOE efficiency rule?

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** carries a verified 4.01 UEF rating (Pass: +1.51 / +60.4%), ranking #104 of 706 (top 14.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** need?

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** stands 59.1 in. high with a 20.2 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** require?

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** cost per year to run?

Rated at 1,238 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** costs about $225/yr ($2,250 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $584/yr in Hawaii).

Who should NOT install AMERICAN STANDARD WATER HEATERS ASHPWH-80*****, and what are its limits?

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can AMERICAN STANDARD WATER HEATERS ASHPWH-80***** serve at peak demand?

AMERICAN STANDARD WATER HEATERS ASHPWH-80***** achieves a 87 gal First Hour Rating (+15 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for AMERICAN STANDARD WATER HEATERS ASHPWH-80*****?

CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to AMERICAN STANDARD WATER HEATERS ASHPWH-80*****, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-80 (4.01 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks