AMERICAN STANDARD WATER HEATERS ASHPWH-80***** Water Heater Specifications (4.01 UEF)
Certified at 4.01 UEF across its 73-gallon nominal tank, 87 gal First Hour Rating, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (Hybrid/Electric Heat Pump, Electric) places #104 of 706 out of 706 ENERGY STAR models (PD 2408486). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.51 / +60.4%. Rated annual electricity draw of 1,238 kWh/yr equates to roughly $225/yr ($2,248 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-80 (4.01 UEF).
- Uniform Energy Factor
- 4.01 UEF
- Cohort UEF Rank
- #104 of 706 (top 14.9%)
- First Hour Rating
- 87 gal
- Storage Volume
- 73 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.51 / +60.4%

Tested at 4.01 UEF, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** places #104 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.31 UEF vs. 3.70 UEF median).
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.51 UEF (+60.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,238 kWh/yr for AMERICAN STANDARD WATER HEATERS ASHPWH-80***** runs ~$225/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for AMERICAN STANDARD WATER HEATERS ASHPWH-80*****: 10-year operating spend spans $1,811 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,841 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to AMERICAN STANDARD WATER HEATERS ASHPWH-80***** include Ariston ARIHPWH-80 (4.01 UEF, at parity) alongside A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, delta -0.21).
Which Specs Set AMERICAN STANDARD WATER HEATERS ASHPWH-80***** Apart From Cohort Averages?
Ranked #104 of 706 (top 14.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | AMERICAN STANDARD WATER HEATERS | 4 certified listings | ENERGY STAR PD 2408486 |
| Model Number | ASHPWH-80***** | Draw pattern: High-Usage | ASHPWH-80***** |
| Uniform Energy Factor (UEF) | 4.01 | +0.31 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,238 kWh/yr | +166 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 443% | +14.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59.1" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-04 | Certified 2026-02-04 | Markets: United States, Canada |
How Do Regional kWh Prices Impact ASHPWH-80***** Over 10 Years?
Using EIA Table 5.6.A benchmarks, AMERICAN STANDARD WATER HEATERS ASHPWH-80*****'s 1,238 kWh/yr draw translates to roughly $225/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,248 | $7,551 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $584/yr | $5,841 | $19,617 |
| California | 29.75 ¢/kWh ($0.2975) | $368/yr | $3,683 | $12,370 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,970 | $6,615 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,811 | $6,083 |
What Should AMERICAN STANDARD WATER HEATERS Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to AMERICAN STANDARD WATER HEATERS; verify whether your ASHPWH-80***** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Ariston ARIHPWH-80 | Hybrid/Electric Heat Pump | 73 gal | 87 gal | 4.01 (at parity) | 1,238 |
| A. O. Smith HPACO-45 1**+AXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
| American MHPCO-45 1**+MXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
| Giant GTHPCO-45 1**+GTXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
| A. O. Smith HPACO-45 1**+AXST-80TTP 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
What Are the Limitations of AMERICAN STANDARD WATER HEATERS ASHPWH-80***** and Who Should Not Install It?
Before ordering AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (Hybrid/Electric Heat Pump, 4.01 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- AMERICAN STANDARD WATER HEATERS ASHPWH-80***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting AMERICAN STANDARD WATER HEATERS ASHPWH-80***** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: AMERICAN STANDARD WATER HEATERS ASHPWH-80*****
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** pass the May 6, 2029 federal DOE efficiency rule?
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** carries a verified 4.01 UEF rating (Pass: +1.51 / +60.4%), ranking #104 of 706 (top 14.9%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** need?
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** stands 59.1 in. high with a 20.2 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** require?
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does AMERICAN STANDARD WATER HEATERS ASHPWH-80***** cost per year to run?
Rated at 1,238 kWh/yr, AMERICAN STANDARD WATER HEATERS ASHPWH-80***** costs about $225/yr ($2,250 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $584/yr in Hawaii).
Who should NOT install AMERICAN STANDARD WATER HEATERS ASHPWH-80*****, and what are its limits?
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can AMERICAN STANDARD WATER HEATERS ASHPWH-80***** serve at peak demand?
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** achieves a 87 gal First Hour Rating (+15 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for AMERICAN STANDARD WATER HEATERS ASHPWH-80*****?
CPSC SaferProducts records show 2 brand-level recall notices mentioning AMERICAN STANDARD WATER HEATERS as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to AMERICAN STANDARD WATER HEATERS ASHPWH-80*****, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-80 (4.01 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)