Skip to main content
ENERGY STAR water heater model · PD 3942615

Ariston ARIHPWH-80 Water Heater Specifications (4.01 UEF)

The Ariston ARIHPWH-80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.01 UEF rating across its 73-gallon nominal tank, 87 gal First Hour Rating, ranking #104 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3942615). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.51 / +60.4%. Rated annual electricity draw of 1,238 kWh/yr equates to roughly $225/yr ($2,248 over 10 years) at 18.16 cents/kWh. Closest certified alternative is AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF).

Uniform Energy Factor
4.01 UEF
Cohort UEF Rank
#104 of 706 (top 14.9%)
First Hour Rating
87 gal
Storage Volume
73 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.51 / +60.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Ariston ARIHPWH-80 at 4.01 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Ariston ARIHPWH-80: 4.01
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Ariston ARIHPWH-80 relative to the cohort median.
Efficiency comparison & rule summary

Ariston ARIHPWH-80 (4.01 UEF) ranks #104 of 706 Hybrid/Electric Heat Pump models — 2-way tie; top 14.9%, more efficient than 85.1% of Hybrid/Electric Heat Pump models, +0.31 UEF above the 3.70 UEF median.

Federal 2029 margin for Ariston ARIHPWH-80: +1.51 UEF (+60.4%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,238 kWh/yr for Ariston ARIHPWH-80 runs ~$225/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for Ariston ARIHPWH-80: 10-year operating spend spans $1,811 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,841 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Ariston ARIHPWH-80 (4.01 UEF) compares closely with AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF, at parity) and A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, delta -0.21).

What Physical and Thermal Ratings Define Ariston ARIHPWH-80?

Positioning at #104 of 706 (top 14.9%) out of 706 Hybrid/Electric Heat Pump peers, Ariston ARIHPWH-80 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAriston8 certified listingsENERGY STAR PD 3942615
Model NumberARIHPWH-80Draw pattern: High-UsageARIHPWH-80
Uniform Energy Factor (UEF)4.01+0.31 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)87 gal+15 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,238 kWh/yr+166 kWh/yr vs. 1,072 kWh/yr medianEst. $225/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency443%+14.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)59.1" H x 20.2" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-02-04Certified 2026-02-04Markets: United States, Canada

Why Do State Utility Rates Shift ARIHPWH-80 Running Costs?

Consuming 1,238 kWh annually puts Ariston ARIHPWH-80 near $225/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,238 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$225.00/yrHawaii$584.00/yrCalifornia$368.00/yrTexas$197.00/yrWashington$181.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $225/yr $2,248 $7,551
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $584/yr $5,841 $19,617
California 29.75 ¢/kWh ($0.2975) $368/yr $3,683 $12,370
Texas 15.91 ¢/kWh ($0.1591) $197/yr $1,970 $6,615
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $181/yr $1,811 $6,083
Estimated electricity spend (1,238 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Ariston Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Ariston; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Ariston ARIHPWH-80?

Homeowners cross-shopping Ariston ARIHPWH-80 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
AMERICAN STANDARD WATER HEATERS ASHPWH-80***** Hybrid/Electric Heat Pump 73 gal 87 gal 4.01 (at parity) 1,238
A. O. Smith HPACO-45 1**+AXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306
American MHPCO-45 1**+MXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306
Giant GTHPCO-45 1**+GTXST-80 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306
A. O. Smith HPACO-45 1**+AXST-80TTP 1** Hybrid/Electric Heat Pump 73 gal 95 gal 3.8 (-0.21) 1,306

Who Is Ariston ARIHPWH-80 Best For — and When Should You Pick AMERICAN STANDARD WATER HEATERS ASHPWH-80*****?

Evaluate whether Ariston ARIHPWH-80's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Ariston ARIHPWH-80 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-80 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Ariston ARIHPWH-80 Strong Fit — 4.01 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare AMERICAN STANDARD WATER HEATERS ASHPWH-80***** footprint.

Sizing, Efficiency & Recall Answers for Ariston ARIHPWH-80

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Ariston ARIHPWH-80 (4.01 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Ariston ARIHPWH-80 records 4.01 UEF (Pass: +1.51 / +60.4%), placing #104 of 706 (top 14.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Ariston ARIHPWH-80 fit inside a tight hallway closet or low-headroom utility room?

Ariston ARIHPWH-80 requires room for its 59.1 in. vertical shell and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Ariston ARIHPWH-80?

For Ariston ARIHPWH-80, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Ariston ARIHPWH-80?

Using 1,238 kWh/yr, Ariston ARIHPWH-80 generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $584/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Ariston ARIHPWH-80 (4.01 UEF)?

Ariston ARIHPWH-80 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or AMERICAN STANDARD WATER HEATERS ASHPWH-80*****.

What hot-water delivery rating governs Ariston ARIHPWH-80?

Rated for 87 gal FHR (+15 gal vs. 72 gal median), Ariston ARIHPWH-80 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Ariston ARIHPWH-80 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Ariston; use our browser-only serial decoder to inspect Ariston ARIHPWH-80's age and warranty window.

What alternative models sit closest to Ariston ARIHPWH-80 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks