Ariston ARIHPWH-80 Water Heater Specifications (4.01 UEF)
The Ariston ARIHPWH-80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.01 UEF rating across its 73-gallon nominal tank, 87 gal First Hour Rating, ranking #104 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3942615). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.51 / +60.4%. Rated annual electricity draw of 1,238 kWh/yr equates to roughly $225/yr ($2,248 over 10 years) at 18.16 cents/kWh. Closest certified alternative is AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF).
- Uniform Energy Factor
- 4.01 UEF
- Cohort UEF Rank
- #104 of 706 (top 14.9%)
- First Hour Rating
- 87 gal
- Storage Volume
- 73 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.51 / +60.4%

Ariston ARIHPWH-80 (4.01 UEF) ranks #104 of 706 Hybrid/Electric Heat Pump models — 2-way tie; top 14.9%, more efficient than 85.1% of Hybrid/Electric Heat Pump models, +0.31 UEF above the 3.70 UEF median.
Federal 2029 margin for Ariston ARIHPWH-80: +1.51 UEF (+60.4%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,238 kWh/yr for Ariston ARIHPWH-80 runs ~$225/yr vs. ~$980/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ariston ARIHPWH-80: 10-year operating spend spans $1,811 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,841 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Ariston ARIHPWH-80 (4.01 UEF) compares closely with AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF, at parity) and A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, delta -0.21).
What Physical and Thermal Ratings Define Ariston ARIHPWH-80?
Positioning at #104 of 706 (top 14.9%) out of 706 Hybrid/Electric Heat Pump peers, Ariston ARIHPWH-80 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ariston | 8 certified listings | ENERGY STAR PD 3942615 |
| Model Number | ARIHPWH-80 | Draw pattern: High-Usage | ARIHPWH-80 |
| Uniform Energy Factor (UEF) | 4.01 | +0.31 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,238 kWh/yr | +166 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 443% | +14.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59.1" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-04 | Certified 2026-02-04 | Markets: United States, Canada |
Why Do State Utility Rates Shift ARIHPWH-80 Running Costs?
Consuming 1,238 kWh annually puts Ariston ARIHPWH-80 near $225/yr at US baseline tariffs, with multi-state EIA comparisons charted below.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,248 | $7,551 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $584/yr | $5,841 | $19,617 |
| California | 29.75 ¢/kWh ($0.2975) | $368/yr | $3,683 | $12,370 |
| Texas | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,970 | $6,615 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,811 | $6,083 |
Have Any Ariston Series Triggered CPSC Recalls?
SaferProducts screening on 2026-11-23 returned zero recall matches for Ariston; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.
What Are 5 Direct Alternatives to Ariston ARIHPWH-80?
Homeowners cross-shopping Ariston ARIHPWH-80 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| AMERICAN STANDARD WATER HEATERS ASHPWH-80***** | Hybrid/Electric Heat Pump | 73 gal | 87 gal | 4.01 (at parity) | 1,238 |
| A. O. Smith HPACO-45 1**+AXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
| American MHPCO-45 1**+MXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
| Giant GTHPCO-45 1**+GTXST-80 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
| A. O. Smith HPACO-45 1**+AXST-80TTP 1** | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (-0.21) | 1,306 |
Who Is Ariston ARIHPWH-80 Best For — and When Should You Pick AMERICAN STANDARD WATER HEATERS ASHPWH-80*****?
Evaluate whether Ariston ARIHPWH-80's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Ariston ARIHPWH-80 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-80 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for Ariston ARIHPWH-80
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Ariston ARIHPWH-80 (4.01 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Ariston ARIHPWH-80 records 4.01 UEF (Pass: +1.51 / +60.4%), placing #104 of 706 (top 14.9%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Ariston ARIHPWH-80 fit inside a tight hallway closet or low-headroom utility room?
Ariston ARIHPWH-80 requires room for its 59.1 in. vertical shell and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Ariston ARIHPWH-80?
For Ariston ARIHPWH-80, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Ariston ARIHPWH-80?
Using 1,238 kWh/yr, Ariston ARIHPWH-80 generates an estimated $225/yr electric bill at 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $584/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Ariston ARIHPWH-80 (4.01 UEF)?
Ariston ARIHPWH-80 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or AMERICAN STANDARD WATER HEATERS ASHPWH-80*****.
What hot-water delivery rating governs Ariston ARIHPWH-80?
Rated for 87 gal FHR (+15 gal vs. 72 gal median), Ariston ARIHPWH-80 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Ariston ARIHPWH-80 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Ariston; use our browser-only serial decoder to inspect Ariston ARIHPWH-80's age and warranty window.
What alternative models sit closest to Ariston ARIHPWH-80 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is AMERICAN STANDARD WATER HEATERS ASHPWH-80***** (4.01 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)