ENERGY STAR water heater model · PD 2408889

American HPHE10250H045DVCTA-1** Water Heater Specifications (3.45 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, American HPHE10250H045DVCTA-1** (Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating (rank #563 of 706, PD 2408889) and verifies as Pass: +1.15 / +50.0% for 2029 DOE floors. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
66 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPHE10250H045DVCTA-1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30American HPHE10250H045DVCTA-1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE10250H045DVCTA-1** relative to the cohort median.
Efficiency comparison & rule summary

American HPHE10250H045DVCTA-1** records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: American HPHE10250H045DVCTA-1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0%). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for American HPHE10250H045DVCTA-1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE10250H045DVCTA-1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside American HPHE10250H045DVCTA-1** (3.45 UEF) are A. O. Smith HP1050H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA052KD 1** (3.45 UEF, at parity).

How Complete Are the Certified Metrics for American HPHE10250H045DVCTA-1**?

Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, American HPHE10250H045DVCTA-1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408889
Model NumberHPHE10250H045DVCTA-1**Draw pattern: Medium-UsageHPHE10250H045DVCTA-1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)66 gal-6 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Is the Projected Utility Bill for HPHE10250H045DVCTA-1** by State?

At 902 kWh/yr, American HPHE10250H045DVCTA-1** averages about $164/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,504
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $11,701
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,378
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $3,946
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,628
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are American Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to HPHE10250H045DVCTA-1**?

Ordered by minimal capacity and UEF spread relative to American HPHE10250H045DVCTA-1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1050H45DV 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
Lochinvar HPA052KD 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
State HPX-50-DHPTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
A. O. Smith HP1050H45DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902

What Are the Limitations of American HPHE10250H045DVCTA-1** and Who Should Not Install It?

Before ordering American HPHE10250H045DVCTA-1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • American HPHE10250H045DVCTA-1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPHE10250H045DVCTA-1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPHE10250H045DVCTA-1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1050H45DV 1** footprint.

Practical Specs & Code Questions for American HPHE10250H045DVCTA-1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does American HPHE10250H045DVCTA-1** pass the May 6, 2029 federal DOE efficiency rule?

American HPHE10250H045DVCTA-1** carries a verified 3.45 UEF rating (Pass: +1.15 / +50.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does American HPHE10250H045DVCTA-1** need?

American HPHE10250H045DVCTA-1** stands 63 in. high with a 15 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does American HPHE10250H045DVCTA-1** require?

American HPHE10250H045DVCTA-1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does American HPHE10250H045DVCTA-1** cost per year to run?

Rated at 902 kWh/yr, American HPHE10250H045DVCTA-1** costs about $164/yr ($1,640 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii).

Who should NOT install American HPHE10250H045DVCTA-1**, and what are its limits?

American HPHE10250H045DVCTA-1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can American HPHE10250H045DVCTA-1** serve at peak demand?

American HPHE10250H045DVCTA-1** achieves a 66 gal First Hour Rating (-6 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for American HPHE10250H045DVCTA-1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to American HPHE10250H045DVCTA-1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks