A. O. Smith HP1050H45DVCTA-1** Water Heater Specifications (3.45 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HP1050H45DVCTA-1** (Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating (rank #563 of 706, PD 2408884) and verifies as Pass: +1.15 / +50.0% for 2029 DOE floors. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPHE10250H045DVCTA-1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 66 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.15 / +50.0%

A. O. Smith HP1050H45DVCTA-1** records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: A. O. Smith HP1050H45DVCTA-1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0%). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for A. O. Smith HP1050H45DVCTA-1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HP1050H45DVCTA-1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside A. O. Smith HP1050H45DVCTA-1** (3.45 UEF) are American HPHE10250H045DVCTA-1** (3.45 UEF, at parity) and Lochinvar HPA052KD 1** (3.45 UEF, at parity).
Where Does A. O. Smith HP1050H45DVCTA-1** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, A. O. Smith HP1050H45DVCTA-1** holds #563 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2408884 |
| Model Number | HP1050H45DVCTA-1** | Draw pattern: Medium-Usage | HP1050H45DVCTA-1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
How Much Electricity Does HP1050H45DVCTA-1** Use in Different States?
Estimated at $164/yr nationally (902 kWh/yr), 10-year utility spending for A. O. Smith HP1050H45DVCTA-1** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,504 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $11,701 |
| California | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,378 |
| Texas | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $3,946 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,628 |
Does CPSC Flag Any Safety Notices on A. O. Smith Units?
Checking 2026-11-23 SaferProducts data shows 4 notices mentioning A. O. Smith; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to HP1050H45DVCTA-1**?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to A. O. Smith HP1050H45DVCTA-1**'s gallon capacity and 3.45 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American HPHE10250H045DVCTA-1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| Lochinvar HPA052KD 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| State HPX-50-DHPTCTA 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| American HPHE10250H045DVDR 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
Who Is A. O. Smith HP1050H45DVCTA-1** Best For — and When Should You Pick American HPHE10250H045DVCTA-1**?
Evaluate whether A. O. Smith HP1050H45DVCTA-1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- A. O. Smith HP1050H45DVCTA-1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HP1050H45DVCTA-1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for A. O. Smith HP1050H45DVCTA-1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does A. O. Smith HP1050H45DVCTA-1** (3.45 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith HP1050H45DVCTA-1** records 3.45 UEF (Pass: +1.15 / +50.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does A. O. Smith HP1050H45DVCTA-1** fit inside a tight hallway closet or low-headroom utility room?
A. O. Smith HP1050H45DVCTA-1** requires room for its 63 in. vertical shell and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern A. O. Smith HP1050H45DVCTA-1**?
For A. O. Smith HP1050H45DVCTA-1**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for A. O. Smith HP1050H45DVCTA-1**?
Using 902 kWh/yr, A. O. Smith HP1050H45DVCTA-1** generates an estimated $164/yr electric bill at 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of A. O. Smith HP1050H45DVCTA-1** (3.45 UEF)?
A. O. Smith HP1050H45DVCTA-1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or American HPHE10250H045DVCTA-1**.
What hot-water delivery rating governs A. O. Smith HP1050H45DVCTA-1**?
Rated for 66 gal FHR (-6 gal vs. 72 gal median), A. O. Smith HP1050H45DVCTA-1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen A. O. Smith HP1050H45DVCTA-1** for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to A. O. Smith HP1050H45DVCTA-1** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is American HPHE10250H045DVCTA-1** (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)