Skip to main content
ENERGY STAR water heater model · PD 2408888

State HPX-50-DHPTCTA 1** Water Heater Specifications (3.45 UEF)

With PD 2408888 certification, State HPX-50-DHPTCTA 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +1.15 / +50.0% for May 6, 2029. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
66 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HPX-50-DHPTCTA 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30State HPX-50-DHPTCTA 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPX-50-DHPTCTA 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places State HPX-50-DHPTCTA 1** at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: State HPX-50-DHPTCTA 1** stands +1.15 UEF (+50.0%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for State HPX-50-DHPTCTA 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPX-50-DHPTCTA 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HP1050H45DV 1** (3.45 UEF, at parity) and American HPHE10250H045DVCTA-1** (3.45 UEF, at parity) bracket State HPX-50-DHPTCTA 1**.

Which Specs Set State HPX-50-DHPTCTA 1** Apart From Cohort Averages?

Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, State HPX-50-DHPTCTA 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2408888
Model NumberHPX-50-DHPTCTA 1**Draw pattern: Medium-UsageHPX-50-DHPTCTA 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)66 gal-6 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

How Do Regional kWh Prices Impact HPX-50-DHPTCTA 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, State HPX-50-DHPTCTA 1**'s 902 kWh/yr draw translates to roughly $164/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,504
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $11,701
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,378
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $3,946
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,628
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should State Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to State; verify whether your HPX-50-DHPTCTA 1** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1050H45DV 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
American HPHE10250H045DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
Lochinvar HPA052KD 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
A. O. Smith HP1050H45DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902

What Are the Limitations of State HPX-50-DHPTCTA 1** and Who Should Not Install It?

Before ordering State HPX-50-DHPTCTA 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • State HPX-50-DHPTCTA 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State HPX-50-DHPTCTA 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HPX-50-DHPTCTA 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1050H45DV 1** footprint.

Frequently Asked Technical Questions: State HPX-50-DHPTCTA 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does State HPX-50-DHPTCTA 1** pass the May 6, 2029 federal DOE efficiency rule?

State HPX-50-DHPTCTA 1** carries a verified 3.45 UEF rating (Pass: +1.15 / +50.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

What doorway width and ceiling height does State HPX-50-DHPTCTA 1** need?

State HPX-50-DHPTCTA 1** stands 63 in. high with a 15 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does State HPX-50-DHPTCTA 1** require?

State HPX-50-DHPTCTA 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

How much electricity or energy does State HPX-50-DHPTCTA 1** cost per year to run?

Rated at 902 kWh/yr, State HPX-50-DHPTCTA 1** costs about $164/yr ($1,640 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii).

Who should NOT install State HPX-50-DHPTCTA 1**, and what are its limits?

State HPX-50-DHPTCTA 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

How many bathrooms or people can State HPX-50-DHPTCTA 1** serve at peak demand?

State HPX-50-DHPTCTA 1** achieves a 66 gal First Hour Rating (-6 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for State HPX-50-DHPTCTA 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to State HPX-50-DHPTCTA 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks