American HPHE10250H045DVDR 1** Water Heater Specifications (3.45 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPHE10250H045DVDR 1** achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408892), recording Pass: +1.15 / +50.0% under 2029 DOE rules. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1050H45DV 1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 66 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.15 / +50.0%

Within the 706-unit Hybrid/Electric Heat Pump cohort, American HPHE10250H045DVDR 1** logs 3.45 UEF and ranks #563 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), American HPHE10250H045DVDR 1** holds a +1.15 UEF (+50.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for American HPHE10250H045DVDR 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPHE10250H045DVDR 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping American HPHE10250H045DVDR 1** (3.45 UEF)? Check A. O. Smith HP1050H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA052KD 1** (3.45 UEF, at parity).
How Do American HPHE10250H045DVDR 1** Specs Compare to Hybrid/Electric Heat Pump Medians?
American HPHE10250H045DVDR 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408892 |
| Model Number | HPHE10250H045DVDR 1** | Draw pattern: Medium-Usage | HPHE10250H045DVDR 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 66 gal | -6 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
What Does HPHE10250H045DVDR 1** Cost to Operate Across State Electricity Rates?
At 902 kWh/yr, American HPHE10250H045DVDR 1** runs roughly $164/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,504 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $11,701 |
| California | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,378 |
| Texas | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $3,946 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,628 |
Are There Active CPSC Safety Recalls for American Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match HPHE10250H045DVDR 1** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to American HPHE10250H045DVDR 1** by storage capacity and 3.45 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HP1050H45DV 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| Lochinvar HPA052KD 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| State HPX-50-DHPTCTA 1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
| A. O. Smith HP1050H45DVCTA-1** | Hybrid/Electric Heat Pump | 46 gal | 66 gal | 3.45 (at parity) | 902 |
Who Is American HPHE10250H045DVDR 1** Best For — and When Should You Pick A. O. Smith HP1050H45DV 1**?
Evaluate whether American HPHE10250H045DVDR 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- American HPHE10250H045DVDR 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPHE10250H045DVDR 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About American HPHE10250H045DVDR 1**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does American HPHE10250H045DVDR 1** (3.45 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American HPHE10250H045DVDR 1** records 3.45 UEF (Pass: +1.15 / +50.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does American HPHE10250H045DVDR 1** fit inside a tight hallway closet or low-headroom utility room?
American HPHE10250H045DVDR 1** requires room for its 63 in. vertical shell and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern American HPHE10250H045DVDR 1**?
For American HPHE10250H045DVDR 1**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for American HPHE10250H045DVDR 1**?
Using 902 kWh/yr, American HPHE10250H045DVDR 1** generates an estimated $164/yr electric bill at 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of American HPHE10250H045DVDR 1** (3.45 UEF)?
American HPHE10250H045DVDR 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HP1050H45DV 1**.
What hot-water delivery rating governs American HPHE10250H045DVDR 1**?
Rated for 66 gal FHR (-6 gal vs. 72 gal median), American HPHE10250H045DVDR 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen American HPHE10250H045DVDR 1** for recalls and tank age?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to American HPHE10250H045DVDR 1** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1050H45DV 1** (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)