ENERGY STAR water heater model · PD 2408892

American HPHE10250H045DVDR 1** Water Heater Specifications (3.45 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPHE10250H045DVDR 1** achieves a certified 3.45 UEF rating across its 46-gallon nominal tank, 66 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408892), recording Pass: +1.15 / +50.0% under 2029 DOE rules. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HP1050H45DV 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
66 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.15 / +50.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPHE10250H045DVDR 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30American HPHE10250H045DVDR 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE10250H045DVDR 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, American HPHE10250H045DVDR 1** logs 3.45 UEF and ranks #563 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), American HPHE10250H045DVDR 1** holds a +1.15 UEF (+50.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for American HPHE10250H045DVDR 1** runs ~$164/yr vs. ~$614/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE10250H045DVDR 1**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping American HPHE10250H045DVDR 1** (3.45 UEF)? Check A. O. Smith HP1050H45DV 1** (3.45 UEF, at parity) and Lochinvar HPA052KD 1** (3.45 UEF, at parity).

How Do American HPHE10250H045DVDR 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

American HPHE10250H045DVDR 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408892
Model NumberHPHE10250H045DVDR 1**Draw pattern: Medium-UsageHPHE10250H045DVDR 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)66 gal-6 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use902 kWh/yr-170 kWh/yr vs. 1,072 kWh/yr medianEst. $164/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency407%-22.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Does HPHE10250H045DVDR 1** Cost to Operate Across State Electricity Rates?

At 902 kWh/yr, American HPHE10250H045DVDR 1** runs roughly $164/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (902 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$164.00/yrHawaii$426.00/yrCalifornia$268.00/yrTexas$144.00/yrWashington$132.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $164/yr $1,638 $4,504
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $426/yr $4,256 $11,701
California 29.75 ¢/kWh ($0.2975) $268/yr $2,683 $7,378
Texas 15.91 ¢/kWh ($0.1591) $144/yr $1,435 $3,946
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $132/yr $1,320 $3,628
Estimated electricity spend (902 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for American Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match HPHE10250H045DVDR 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to American HPHE10250H045DVDR 1** by storage capacity and 3.45 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HP1050H45DV 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
Lochinvar HPA052KD 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
RELIANCE WATER HEATERS 10-50-DHPHTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
State HPX-50-DHPTCTA 1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902
A. O. Smith HP1050H45DVCTA-1** Hybrid/Electric Heat Pump 46 gal 66 gal 3.45 (at parity) 902

Who Is American HPHE10250H045DVDR 1** Best For — and When Should You Pick A. O. Smith HP1050H45DV 1**?

Evaluate whether American HPHE10250H045DVDR 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • American HPHE10250H045DVDR 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPHE10250H045DVDR 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPHE10250H045DVDR 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HP1050H45DV 1** footprint.

What Are the Key Questions About American HPHE10250H045DVDR 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does American HPHE10250H045DVDR 1** (3.45 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American HPHE10250H045DVDR 1** records 3.45 UEF (Pass: +1.15 / +50.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

Does American HPHE10250H045DVDR 1** fit inside a tight hallway closet or low-headroom utility room?

American HPHE10250H045DVDR 1** requires room for its 63 in. vertical shell and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern American HPHE10250H045DVDR 1**?

For American HPHE10250H045DVDR 1**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for American HPHE10250H045DVDR 1**?

Using 902 kWh/yr, American HPHE10250H045DVDR 1** generates an estimated $164/yr electric bill at 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of American HPHE10250H045DVDR 1** (3.45 UEF)?

American HPHE10250H045DVDR 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HP1050H45DV 1**.

What hot-water delivery rating governs American HPHE10250H045DVDR 1**?

Rated for 66 gal FHR (-6 gal vs. 72 gal median), American HPHE10250H045DVDR 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen American HPHE10250H045DVDR 1** for recalls and tank age?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to American HPHE10250H045DVDR 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HP1050H45DV 1** (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks