Skip to main content
ENERGY STAR water heater model · PD 2408863

American HPHE10266H045DVCTA-1** Water Heater Specifications (3.45 UEF)

With PD 2408863 certification, American HPHE10266H045DVCTA-1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating, standing #563 of 706 across 706 peers with Pass: +0.95 / +38.0% for May 6, 2029. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
79 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking American HPHE10266H045DVCTA-1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50American HPHE10266H045DVCTA-1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows American HPHE10266H045DVCTA-1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places American HPHE10266H045DVCTA-1** at 3.45 UEF (#563 of 706; -0.25 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: American HPHE10266H045DVCTA-1** stands +0.95 UEF (+38.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for American HPHE10266H045DVCTA-1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.

State electric sensitivity for American HPHE10266H045DVCTA-1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) and Lochinvar HPA068KD 1** (3.45 UEF, at parity) bracket American HPHE10266H045DVCTA-1**.

What Physical and Thermal Ratings Define American HPHE10266H045DVCTA-1**?

Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, American HPHE10266H045DVCTA-1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408863
Model NumberHPHE10266H045DVCTA-1**Draw pattern: High-UsageHPHE10266H045DVCTA-1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)79 gal+7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,381 kWh/yr+309 kWh/yr vs. 1,072 kWh/yr medianEst. $251/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency265%-164.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

Why Do State Utility Rates Shift HPHE10266H045DVCTA-1** Running Costs?

Consuming 1,381 kWh annually puts American HPHE10266H045DVCTA-1** near $251/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,381 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$251.00/yrHawaii$652.00/yrCalifornia$411.00/yrTexas$220.00/yrWashington$202.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $251/yr $2,508 $6,897
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $652/yr $6,516 $17,919
California 29.75 ¢/kWh ($0.2975) $411/yr $4,108 $11,299
Texas 15.91 ¢/kWh ($0.1591) $220/yr $2,197 $6,043
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $202/yr $2,020 $5,556
Estimated electricity spend (1,381 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any American Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to American HPHE10266H045DVCTA-1**?

Homeowners cross-shopping American HPHE10266H045DVCTA-1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTU-66CTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
Lochinvar HPA068KD 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
State HPX-66-DHPTCTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
A. O. Smith HPTU-66DR 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381

Which Home Setups Are NOT a Fit for American HPHE10266H045DVCTA-1**?

Comparing American HPHE10266H045DVCTA-1** against A. O. Smith HPTU-66CTA 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • American HPHE10266H045DVCTA-1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting American HPHE10266H045DVCTA-1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing American HPHE10266H045DVCTA-1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTU-66CTA 1** footprint.

Sizing, Efficiency & Recall Answers for American HPHE10266H045DVCTA-1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does American HPHE10266H045DVCTA-1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; American HPHE10266H045DVCTA-1** logs 3.45 UEF (Pass: +0.95 / +38.0%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing American HPHE10266H045DVCTA-1**?

With a 61 in. height and 23 in. diameter, American HPHE10266H045DVCTA-1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits American HPHE10266H045DVCTA-1**?

Powered via 240V at 22A max, American HPHE10266H045DVCTA-1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for American HPHE10266H045DVCTA-1**?

Annual electric spend for American HPHE10266H045DVCTA-1** (1,381 kWh/yr) averages $251/yr nationwide (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing American HPHE10266H045DVCTA-1**?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on American HPHE10266H045DVCTA-1**.

Is American HPHE10266H045DVCTA-1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies American HPHE10266H045DVCTA-1** at 79 gal First Hour Rating (+7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does American have active CPSC SaferProducts notices affecting HPHE10266H045DVCTA-1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches American HPHE10266H045DVCTA-1** (3.45 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for American HPHE10266H045DVCTA-1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks