State HPX-66-DHPTCTA 1** Water Heater Specifications (3.45 UEF)

The State HPX-66-DHPTCTA 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating, ranking #563 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408870). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
79 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking State HPX-66-DHPTCTA 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50State HPX-66-DHPTCTA 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows State HPX-66-DHPTCTA 1** relative to the cohort median.
Efficiency comparison & rule summary

State HPX-66-DHPTCTA 1** (3.45 UEF) ranks #563 of 706 Hybrid/Electric Heat Pump models — 59-way tie; more efficient than 12% of Hybrid/Electric Heat Pump models, -0.25 UEF below the 3.70 UEF median.

Federal 2029 margin for State HPX-66-DHPTCTA 1**: +0.95 UEF (+38.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for State HPX-66-DHPTCTA 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.

State electric sensitivity for State HPX-66-DHPTCTA 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: State HPX-66-DHPTCTA 1** (3.45 UEF) compares closely with A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) and American HPHE10266H045DVCTA-1** (3.45 UEF, at parity).

How Do State HPX-66-DHPTCTA 1** Specs Compare to Hybrid/Electric Heat Pump Medians?

State HPX-66-DHPTCTA 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2408870
Model NumberHPX-66-DHPTCTA 1**Draw pattern: High-UsageHPX-66-DHPTCTA 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)79 gal+7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,381 kWh/yr+309 kWh/yr vs. 1,072 kWh/yr medianEst. $251/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency265%-164.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Does HPX-66-DHPTCTA 1** Cost to Operate Across State Electricity Rates?

At 1,381 kWh/yr, State HPX-66-DHPTCTA 1** runs roughly $251/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,381 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$251.00/yrHawaii$652.00/yrCalifornia$411.00/yrTexas$220.00/yrWashington$202.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $251/yr $2,508 $6,897
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $652/yr $6,516 $17,919
California 29.75 ¢/kWh ($0.2975) $411/yr $4,108 $11,299
Texas 15.91 ¢/kWh ($0.1591) $220/yr $2,197 $6,043
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $202/yr $2,020 $5,556
Estimated electricity spend (1,381 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for State Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with State; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match HPX-66-DHPTCTA 1** Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to State HPX-66-DHPTCTA 1** by storage capacity and 3.45 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTU-66CTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
American HPHE10266H045DVCTA-1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
Lochinvar HPA068KD 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
A. O. Smith HPTU-66DR 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381

What Installation Caveats Apply Before Buying State HPX-66-DHPTCTA 1**?

Even high-UEF units like State HPX-66-DHPTCTA 1** (3.45 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • State HPX-66-DHPTCTA 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting State HPX-66-DHPTCTA 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing State HPX-66-DHPTCTA 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTU-66CTA 1** footprint.

What Are the Key Questions About State HPX-66-DHPTCTA 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is State HPX-66-DHPTCTA 1** eligible for continued manufacture past May 6, 2029?

At 3.45 UEF, State HPX-66-DHPTCTA 1** achieves Pass: +0.95 / +38.0% for the 2029 DOE standard and stands #563 of 706 against A. O. Smith HPTU-66CTA 1** and American HPHE10266H045DVCTA-1**.

How tall and wide is State HPX-66-DHPTCTA 1**, and what service clearance is needed?

Physical dimensions for State HPX-66-DHPTCTA 1** are 61 in. height and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)); verify stair turns and drain pan width before delivery.

Will State HPX-66-DHPTCTA 1** require upgrading household electrical panels or gas piping?

State HPX-66-DHPTCTA 1** draws 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is State HPX-66-DHPTCTA 1** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $251/yr ($2,510 over 10 years) to power State HPX-66-DHPTCTA 1** at 1,381 kWh/yr under the 18.16 cents/kWh US average (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii).

Which installation bottlenecks limit State HPX-66-DHPTCTA 1**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, State HPX-66-DHPTCTA 1** drops into resistance mode more often.

How does State HPX-66-DHPTCTA 1** handle simultaneous showers and laundry?

Delivering 79 gal in the first hour (+7 gal vs. 72 gal median), State HPX-66-DHPTCTA 1** combines 67 gal tank storage with rapid burner/element recovery.

How long is the warranty on State HPX-66-DHPTCTA 1** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying State HPX-66-DHPTCTA 1**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks