Lochinvar HPA068KD 1** Water Heater Specifications (3.45 UEF)

The Lochinvar HPA068KD 1** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating, ranking #563 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408875). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Uniform Energy Factor
3.45 UEF
Cohort UEF Rank
#563 of 706
First Hour Rating
79 gal
Storage Volume
67 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.95 / +38.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPA068KD 1** at 3.45 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Lochinvar HPA068KD 1**: 3.45
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPA068KD 1** relative to the cohort median.
Efficiency comparison & rule summary

Lochinvar HPA068KD 1** (3.45 UEF) ranks #563 of 706 Hybrid/Electric Heat Pump models — 59-way tie; more efficient than 12% of Hybrid/Electric Heat Pump models, -0.25 UEF below the 3.70 UEF median.

Federal 2029 margin for Lochinvar HPA068KD 1**: +0.95 UEF (+38.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for Lochinvar HPA068KD 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar HPA068KD 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Lochinvar HPA068KD 1** (3.45 UEF) compares closely with A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) and American HPHE10266H045DVCTA-1** (3.45 UEF, at parity).

How Complete Are the Certified Metrics for Lochinvar HPA068KD 1**?

Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Lochinvar HPA068KD 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 2408875
Model NumberHPA068KD 1**Draw pattern: High-UsageHPA068KD 1**
Uniform Energy Factor (UEF)3.45-0.25 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)79 gal+7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,381 kWh/yr+309 kWh/yr vs. 1,072 kWh/yr medianEst. $251/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency265%-164.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61" H x 23" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 22 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada

What Is the Projected Utility Bill for HPA068KD 1** by State?

At 1,381 kWh/yr, Lochinvar HPA068KD 1** averages about $251/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (1,381 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$251.00/yrHawaii$652.00/yrCalifornia$411.00/yrTexas$220.00/yrWashington$202.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $251/yr $2,508 $6,897
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $652/yr $6,516 $17,919
California 29.75 ¢/kWh ($0.2975) $411/yr $4,108 $11,299
Texas 15.91 ¢/kWh ($0.1591) $220/yr $2,197 $6,043
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $202/yr $2,020 $5,556
Estimated electricity spend (1,381 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Lochinvar Models Affected by Current CPSC Notices?

Review 1 brand-matched CPSC entry pulled 2026-11-23 for Lochinvar and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

Which 5 Models Offer Similar Output to HPA068KD 1**?

Ordered by minimal capacity and UEF spread relative to Lochinvar HPA068KD 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTU-66CTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
American HPHE10266H045DVCTA-1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
State HPX-66-DHPTCTA 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381
A. O. Smith HPTU-66DR 1** Hybrid/Electric Heat Pump 67 gal 79 gal 3.45 (at parity) 1,381

When Should Homeowners Skip Lochinvar HPA068KD 1** (Hybrid/Electric Heat Pump)?

Check Lochinvar HPA068KD 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.95 / +38.0% status—against typical residential installations.

Key Limitations & Exclusions

  • Lochinvar HPA068KD 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Lochinvar HPA068KD 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPA068KD 1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTU-66CTA 1** footprint.

Practical Specs & Code Questions for Lochinvar HPA068KD 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Lochinvar HPA068KD 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.45 UEF, Lochinvar HPA068KD 1** shows Pass: +0.95 / +38.0% relative to May 6, 2029 federal DOE limits while placing #563 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith HPTU-66CTA 1**.

Will Lochinvar HPA068KD 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, Lochinvar HPA068KD 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Lochinvar HPA068KD 1** during replacement?

Electrical specs for Lochinvar HPA068KD 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Lochinvar HPA068KD 1**?

At 18.16 cents/kWh national residential pricing, Lochinvar HPA068KD 1**'s 1,381 kWh/yr draw equals roughly $251 annually or $2,510 across a 10-year horizon (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii).

When is Lochinvar HPA068KD 1** a poor fit for a residential replacement?

Avoid placing Lochinvar HPA068KD 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Lochinvar HPA068KD 1** deliver?

With 79 gal FHR (+7 gal vs. 72 gal median), Lochinvar HPA068KD 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Lochinvar HPA068KD 1**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does Lochinvar HPA068KD 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Lochinvar HPA068KD 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks