American HPHE10266H045DVN 1** Water Heater Specifications (3.45 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, American HPHE10266H045DVN 1** (Electric) achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating (rank #563 of 706, PD 2408879) and verifies as Pass: +0.95 / +38.0% for 2029 DOE floors. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).
- Uniform Energy Factor
- 3.45 UEF
- Cohort UEF Rank
- #563 of 706
- First Hour Rating
- 79 gal
- Storage Volume
- 67 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.95 / +38.0%

American HPHE10266H045DVN 1** records 3.45 UEF efficiency, putting it #563 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: American HPHE10266H045DVN 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for American HPHE10266H045DVN 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPHE10266H045DVN 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside American HPHE10266H045DVN 1** (3.45 UEF) are A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) and Lochinvar HPA068KD 1** (3.45 UEF, at parity).
How Complete Are the Certified Metrics for American HPHE10266H045DVN 1**?
Standing at #563 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, American HPHE10266H045DVN 1** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408879 |
| Model Number | HPHE10266H045DVN 1** | Draw pattern: High-Usage | HPHE10266H045DVN 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 79 gal | +7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,381 kWh/yr | +309 kWh/yr vs. 1,072 kWh/yr median | Est. $251/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 265% | -164.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
What Is the Projected Utility Bill for HPHE10266H045DVN 1** by State?
At 1,381 kWh/yr, American HPHE10266H045DVN 1** averages about $251/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $251/yr | $2,508 | $6,897 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $652/yr | $6,516 | $17,919 |
| California | 29.75 ¢/kWh ($0.2975) | $411/yr | $4,108 | $11,299 |
| Texas | 15.91 ¢/kWh ($0.1591) | $220/yr | $2,197 | $6,043 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $202/yr | $2,020 | $5,556 |
Are American Models Affected by Current CPSC Notices?
Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to HPHE10266H045DVN 1**?
Ordered by minimal capacity and UEF spread relative to American HPHE10266H045DVN 1**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPTU-66CTA 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| Lochinvar HPA068KD 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| State HPX-66-DHPTCTA 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| A. O. Smith HPTU-66DR 1** | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
Which Home Setups Are NOT a Fit for American HPHE10266H045DVN 1**?
Comparing American HPHE10266H045DVN 1** against A. O. Smith HPTU-66CTA 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- American HPHE10266H045DVN 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPHE10266H045DVN 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for American HPHE10266H045DVN 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does American HPHE10266H045DVN 1** score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; American HPHE10266H045DVN 1** logs 3.45 UEF (Pass: +0.95 / +38.0%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing American HPHE10266H045DVN 1**?
With a 61 in. height and 23 in. diameter, American HPHE10266H045DVN 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits American HPHE10266H045DVN 1**?
Powered via 240V at 22A max, American HPHE10266H045DVN 1** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for American HPHE10266H045DVN 1**?
Annual electric spend for American HPHE10266H045DVN 1** (1,381 kWh/yr) averages $251/yr nationwide (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing American HPHE10266H045DVN 1**?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on American HPHE10266H045DVN 1**.
Is American HPHE10266H045DVN 1** sized adequately for a 2-to-4-person household?
ENERGY STAR certifies American HPHE10266H045DVN 1** at 79 gal First Hour Rating (+7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does American have active CPSC SaferProducts notices affecting HPHE10266H045DVN 1**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches American HPHE10266H045DVN 1** (3.45 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for American HPHE10266H045DVN 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)