American HPV10250H009DV 2** Water Heater Specifications (3 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, American HPV10250H009DV 2** achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 52 gal First Hour Rating and ranks #666 of 706 in its 706-model cohort (PD 2862507), recording Pass: +0.70 / +30.4% under 2029 DOE rules. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-50 2** (3.0 UEF).
- Uniform Energy Factor
- 3.0 UEF
- Cohort UEF Rank
- #666 of 706
- First Hour Rating
- 52 gal
- Storage Volume
- 46 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.70 / +30.4%

Within the 706-unit Hybrid/Electric Heat Pump cohort, American HPV10250H009DV 2** logs 3.0 UEF and ranks #666 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), American HPV10250H009DV 2** holds a +0.70 UEF (+30.4%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for American HPV10250H009DV 2** runs ~$281/yr vs. ~$918/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).
State electric sensitivity for American HPV10250H009DV 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping American HPV10250H009DV 2** (3.0 UEF)? Check A. O. Smith HPTV-50 2** (3.0 UEF, at parity) and Lochinvar HPV050KD 2** (3.0 UEF, at parity).
How Complete Are the Certified Metrics for American HPV10250H009DV 2**?
Standing at #666 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, American HPV10250H009DV 2** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2862507 |
| Model Number | HPV10250H009DV 2** | Draw pattern: Medium-Usage | HPV10250H009DV 2** |
| Uniform Energy Factor (UEF) | 3.0 | -0.70 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 52 gal | -20 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,550 kWh/yr | +478 kWh/yr vs. 1,072 kWh/yr median | Est. $281/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 457% | +28.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 15" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
What Is the Projected Utility Bill for HPV10250H009DV 2** by State?
At 1,550 kWh/yr, American HPV10250H009DV 2** averages about $281/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $281/yr | $2,815 | $6,363 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $731/yr | $7,313 | $16,532 |
| California | 29.75 ¢/kWh ($0.2975) | $461/yr | $4,611 | $10,424 |
| Texas | 15.91 ¢/kWh ($0.1591) | $247/yr | $2,466 | $5,575 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $227/yr | $2,268 | $5,126 |
Are American Models Affected by Current CPSC Notices?
Review 2 brand-matched CPSC entries pulled 2026-11-23 for American and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which 5 Models Offer Similar Output to HPV10250H009DV 2**?
Ordered by minimal capacity and UEF spread relative to American HPV10250H009DV 2**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith HPTV-50 2** | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| Lochinvar HPV050KD 2** | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| RELIANCE WATER HEATERS 10-50-DHPTV 2** | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| State HPVX-50-DHPT 2** | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
| A. O. Smith HPV10-50H01DV 2** | Hybrid/Electric Heat Pump | 46 gal | 52 gal | 3.0 (at parity) | 1,550 |
What Are the Limitations of American HPV10250H009DV 2** and Who Should Not Install It?
Before ordering American HPV10250H009DV 2** (Hybrid/Electric Heat Pump, 3.0 UEF), weigh space clearances, fuel piping, noise (45 dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- American HPV10250H009DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting American HPV10250H009DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for American HPV10250H009DV 2**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does American HPV10250H009DV 2** pass the May 6, 2029 federal DOE efficiency rule?
American HPV10250H009DV 2** carries a verified 3.0 UEF rating (Pass: +0.70 / +30.4%), ranking #666 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does American HPV10250H009DV 2** need?
American HPV10250H009DV 2** stands 63 in. high with a 15 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does American HPV10250H009DV 2** require?
American HPV10250H009DV 2** uses a 120V branch circuit at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does American HPV10250H009DV 2** cost per year to run?
Rated at 1,550 kWh/yr, American HPV10250H009DV 2** costs about $281/yr ($2,810 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii).
Who should NOT install American HPV10250H009DV 2**, and what are its limits?
American HPV10250H009DV 2** (3.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 45 dBA.
How many bathrooms or people can American HPV10250H009DV 2** serve at peak demand?
American HPV10250H009DV 2** achieves a 52 gal First Hour Rating (-20 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for American HPV10250H009DV 2**?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to American HPV10250H009DV 2**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-50 2** (3.0 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)