Skip to main content
ENERGY STAR water heater model · PD 2862506

Lochinvar HPV050KD 2** Water Heater Specifications (3 UEF)

Certified at 3.0 UEF across its 46-gallon nominal tank, 52 gal First Hour Rating, Lochinvar HPV050KD 2** (Hybrid/Electric Heat Pump, Electric) places #666 of 706 out of 706 ENERGY STAR models (PD 2862506). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.70 / +30.4%. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-50 2** (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
52 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Lochinvar HPV050KD 2** at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Lochinvar HPV050KD 2**: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPV050KD 2** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.0 UEF, Lochinvar HPV050KD 2** places #666 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.70 UEF vs. 3.70 UEF median).

Lochinvar HPV050KD 2** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.70 UEF (+30.4% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for Lochinvar HPV050KD 2** runs ~$281/yr vs. ~$918/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Lochinvar HPV050KD 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Lochinvar HPV050KD 2** include A. O. Smith HPTV-50 2** (3.0 UEF, at parity) alongside American HPV10250H009DV 2** (3.0 UEF, at parity).

Which Specs Set Lochinvar HPV050KD 2** Apart From Cohort Averages?

Ranked #666 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Lochinvar HPV050KD 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 2862506
Model NumberHPV050KD 2**Draw pattern: Medium-UsageHPV050KD 2**
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)52 gal-20 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,550 kWh/yr+478 kWh/yr vs. 1,072 kWh/yr medianEst. $281/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Do Regional kWh Prices Impact HPV050KD 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, Lochinvar HPV050KD 2**'s 1,550 kWh/yr draw translates to roughly $281/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,550 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$281.00/yrHawaii$731.00/yrCalifornia$461.00/yrTexas$247.00/yrWashington$227.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $281/yr $2,815 $6,363
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $731/yr $7,313 $16,532
California 29.75 ¢/kWh ($0.2975) $461/yr $4,611 $10,424
Texas 15.91 ¢/kWh ($0.1591) $247/yr $2,466 $5,575
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $227/yr $2,268 $5,126
Estimated electricity spend (1,550 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Lochinvar Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 1 filing tied to Lochinvar; verify whether your HPV050KD 2** production run falls inside affected ranges. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPTV-50 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
American HPV10250H009DV 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
RELIANCE WATER HEATERS 10-50-DHPTV 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
State HPVX-50-DHPT 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
A. O. Smith HPV10-50H01DV 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550

Which Home Setups Are NOT a Fit for Lochinvar HPV050KD 2**?

Comparing Lochinvar HPV050KD 2** against A. O. Smith HPTV-50 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Lochinvar HPV050KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting Lochinvar HPV050KD 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Lochinvar HPV050KD 2** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPTV-50 2** footprint.

Frequently Asked Technical Questions: Lochinvar HPV050KD 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lochinvar HPV050KD 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lochinvar HPV050KD 2** logs 3.0 UEF (Pass: +0.70 / +30.4%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Lochinvar HPV050KD 2**?

With a 63 in. height and 15 in. diameter, Lochinvar HPV050KD 2** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Lochinvar HPV050KD 2**?

Powered via 120V at 15A max, Lochinvar HPV050KD 2** requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Lochinvar HPV050KD 2**?

Annual electric spend for Lochinvar HPV050KD 2** (1,550 kWh/yr) averages $281/yr nationwide (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Lochinvar HPV050KD 2**?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lochinvar HPV050KD 2**.

Is Lochinvar HPV050KD 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lochinvar HPV050KD 2** at 52 gal First Hour Rating (-20 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Lochinvar have active CPSC SaferProducts notices affecting HPV050KD 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches Lochinvar HPV050KD 2** (3.0 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lochinvar HPV050KD 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-50 2** (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks