ENERGY STAR water heater model · PD 2862509

A. O. Smith HPV10-50H01DV 2** Water Heater Specifications (3 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPV10-50H01DV 2** (Electric) achieves a certified 3.0 UEF rating across its 46-gallon nominal tank, 52 gal First Hour Rating (rank #666 of 706, PD 2862509) and verifies as Pass: +0.70 / +30.4% for 2029 DOE floors. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American HPV10250H009DV 2** (3.0 UEF).

Uniform Energy Factor
3.0 UEF
Cohort UEF Rank
#666 of 706
First Hour Rating
52 gal
Storage Volume
46 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +0.70 / +30.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPV10-50H01DV 2** at 3.0 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30A. O. Smith HPV10-50H01DV 2**: 3.00
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPV10-50H01DV 2** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPV10-50H01DV 2** records 3.0 UEF efficiency, putting it #666 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith HPV10-50H01DV 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +0.70 UEF (+30.4%). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for A. O. Smith HPV10-50H01DV 2** runs ~$281/yr vs. ~$918/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for A. O. Smith HPV10-50H01DV 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith HPV10-50H01DV 2** (3.0 UEF) are American HPV10250H009DV 2** (3.0 UEF, at parity) and Lochinvar HPV050KD 2** (3.0 UEF, at parity).

Which Specs Set A. O. Smith HPV10-50H01DV 2** Apart From Cohort Averages?

Ranked #666 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPV10-50H01DV 2** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 2862509
Model NumberHPV10-50H01DV 2**Draw pattern: Medium-UsageHPV10-50H01DV 2**
Uniform Energy Factor (UEF)3.0-0.70 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)52 gal-20 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,550 kWh/yr+478 kWh/yr vs. 1,072 kWh/yr medianEst. $281/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency457%+28.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)63" H x 15" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" D)Doorway & ceiling check
Electrical Circuit Requirements120 V / 15 A max120V plug-in retrofit circuit; slower heat-pump-only recoveryNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level45 dBAtop 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA medianIndoor placement check
Certification Date2025-12-12Certified 2025-12-12Markets: United States

How Do Regional kWh Prices Impact HPV10-50H01DV 2** Over 10 Years?

Using EIA Table 5.6.A benchmarks, A. O. Smith HPV10-50H01DV 2**'s 1,550 kWh/yr draw translates to roughly $281/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,550 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$281.00/yrHawaii$731.00/yrCalifornia$461.00/yrTexas$247.00/yrWashington$227.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $281/yr $2,815 $6,363
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $731/yr $7,313 $16,532
California 29.75 ¢/kWh ($0.2975) $461/yr $4,611 $10,424
Texas 15.91 ¢/kWh ($0.1591) $247/yr $2,466 $5,575
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $227/yr $2,268 $5,126
Estimated electricity spend (1,550 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should A. O. Smith Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPV10-50H01DV 2** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American HPV10250H009DV 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Lochinvar HPV050KD 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
RELIANCE WATER HEATERS 10-50-DHPTV 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
State HPVX-50-DHPT 2** Hybrid/Electric Heat Pump 46 gal 52 gal 3.0 (at parity) 1,550
Friedrich PROH50 T0 FD120 Hybrid/Electric Heat Pump 46 gal 51 gal 3.0 (at parity) 1,082

What Installation Caveats Apply Before Buying A. O. Smith HPV10-50H01DV 2**?

Even high-UEF units like A. O. Smith HPV10-50H01DV 2** (3.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • A. O. Smith HPV10-50H01DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 45 dBA; avoid mounting A. O. Smith HPV10-50H01DV 2** directly beside quiet bedrooms.
  • Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPV10-50H01DV 2** Strong Fit — 3.0 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American HPV10250H009DV 2** footprint.

Frequently Asked Technical Questions: A. O. Smith HPV10-50H01DV 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith HPV10-50H01DV 2** eligible for continued manufacture past May 6, 2029?

At 3.0 UEF, A. O. Smith HPV10-50H01DV 2** achieves Pass: +0.70 / +30.4% for the 2029 DOE standard and stands #666 of 706 against American HPV10250H009DV 2** and Lochinvar HPV050KD 2**.

How tall and wide is A. O. Smith HPV10-50H01DV 2**, and what service clearance is needed?

Physical dimensions for A. O. Smith HPV10-50H01DV 2** are 63 in. height and 15 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (15" d)); verify stair turns and drain pan width before delivery.

Will A. O. Smith HPV10-50H01DV 2** require upgrading household electrical panels or gas piping?

A. O. Smith HPV10-50H01DV 2** draws 120V at 15A max (120V plug-in retrofit circuit; slower heat-pump-only recovery); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is A. O. Smith HPV10-50H01DV 2** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $281/yr ($2,810 over 10 years) to power A. O. Smith HPV10-50H01DV 2** at 1,550 kWh/yr under the 18.16 cents/kWh US average (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii).

Which installation bottlenecks limit A. O. Smith HPV10-50H01DV 2**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, A. O. Smith HPV10-50H01DV 2** drops into resistance mode more often.

How does A. O. Smith HPV10-50H01DV 2** handle simultaneous showers and laundry?

Delivering 52 gal in the first hour (-20 gal vs. 72 gal median), A. O. Smith HPV10-50H01DV 2** combines 46 gal tank storage with rapid burner/element recovery.

How long is the warranty on A. O. Smith HPV10-50H01DV 2** and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith HPV10-50H01DV 2**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is American HPV10250H009DV 2** (3.0 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks