Arctic Arctic-HP-Hot Water-KA06-50 Water Heater Specifications (3.88 UEF)
Certified at 3.88 UEF across its 44.5-gallon nominal tank, 65 gal First Hour Rating, Arctic Arctic-HP-Hot Water-KA06-50 (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 4576901). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 837 kWh/yr equates to roughly $152/yr ($1,520 over 10 years) at 18.16 cents/kWh. Closest certified alternative is PHNIX KA06-50 (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 65 gal
- Storage Volume
- 44.5 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.58 / +68.7%

Tested at 3.88 UEF, Arctic Arctic-HP-Hot Water-KA06-50 places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).
Arctic Arctic-HP-Hot Water-KA06-50 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 837 kWh/yr for Arctic Arctic-HP-Hot Water-KA06-50 runs ~$152/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Arctic Arctic-HP-Hot Water-KA06-50: 10-year operating spend spans $1,225 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,949 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to Arctic Arctic-HP-Hot Water-KA06-50 include PHNIX KA06-50 (3.88 UEF, at parity) alongside Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity).
How Complete Are the Certified Metrics for Arctic Arctic-HP-Hot Water-KA06-50?
Standing at #165 of 706 (top 30.6%) among 706 certified Hybrid/Electric Heat Pump heaters, Arctic Arctic-HP-Hot Water-KA06-50 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Arctic | 2 certified listings | ENERGY STAR PD 4576901 |
| Model Number | Arctic-HP-Hot Water-KA06-50 | Draw pattern: Medium-Usage | Arctic-HP-Hot Water-KA06-50 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 837 kWh/yr | -235 kWh/yr vs. 1,072 kWh/yr median | Est. $152/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 412% | -17.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.8" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 27 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-03-12 | Certified 2026-03-12 | Markets: United States, Canada |
What Is the Projected Utility Bill for Arctic-HP-Hot Water-KA06-50 by State?
At 837 kWh/yr, Arctic Arctic-HP-Hot Water-KA06-50 averages about $152/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $152/yr | $1,520 | $4,890 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $395/yr | $3,949 | $12,706 |
| California | 29.75 ¢/kWh ($0.2975) | $249/yr | $2,490 | $8,012 |
| Texas | 15.91 ¢/kWh ($0.1591) | $133/yr | $1,332 | $4,285 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $122/yr | $1,225 | $3,940 |
Are Arctic Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Arctic in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to Arctic-HP-Hot Water-KA06-50?
Ordered by minimal capacity and UEF spread relative to Arctic Arctic-HP-Hot Water-KA06-50, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| PHNIX KA06-50 | Hybrid/Electric Heat Pump | 44.5 gal | 65 gal | 3.88 (at parity) | 837 |
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Rheem CPROPH50 T2 RH375-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Richmond 10CE50-HP5S30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
When Should Homeowners Skip Arctic Arctic-HP-Hot Water-KA06-50 (Hybrid/Electric Heat Pump)?
Check Arctic Arctic-HP-Hot Water-KA06-50's mechanical constraints—including utility space, Electric capacity, and Pass: +1.58 / +68.7% status—against typical residential installations.
Key Limitations & Exclusions
- Arctic Arctic-HP-Hot Water-KA06-50 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Arctic Arctic-HP-Hot Water-KA06-50 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Arctic Arctic-HP-Hot Water-KA06-50
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Arctic Arctic-HP-Hot Water-KA06-50 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.88 UEF, Arctic Arctic-HP-Hot Water-KA06-50 shows Pass: +1.58 / +68.7% relative to May 6, 2029 federal DOE limits while placing #165 of 706 (top 30.6%) among 706 Hybrid/Electric Heat Pump peers like PHNIX KA06-50.
Will Arctic Arctic-HP-Hot Water-KA06-50 fit through a standard utility door and 72-inch basement ceiling?
Measuring 46.8 in. tall by 22 in. diameter, Arctic Arctic-HP-Hot Water-KA06-50 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Arctic Arctic-HP-Hot Water-KA06-50 during replacement?
Electrical specs for Arctic Arctic-HP-Hot Water-KA06-50 call for 240V at 27A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Arctic Arctic-HP-Hot Water-KA06-50?
At 18.16 cents/kWh national residential pricing, Arctic Arctic-HP-Hot Water-KA06-50's 837 kWh/yr draw equals roughly $152 annually or $1,520 across a 10-year horizon (ranging from $122/yr in Washington hydro tiers up to $395/yr in Hawaii).
When is Arctic Arctic-HP-Hot Water-KA06-50 a poor fit for a residential replacement?
Avoid placing Arctic Arctic-HP-Hot Water-KA06-50 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Arctic Arctic-HP-Hot Water-KA06-50 deliver?
With 65 gal FHR (-7 gal vs. 72 gal median), Arctic Arctic-HP-Hot Water-KA06-50 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Arctic Arctic-HP-Hot Water-KA06-50?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Arctic; verify exact manufacturing week for Arctic Arctic-HP-Hot Water-KA06-50 using the Serial Number Lookup tool.
Does Arctic Arctic-HP-Hot Water-KA06-50 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Arctic Arctic-HP-Hot Water-KA06-50. Closest peer in Hybrid/Electric Heat Pump is PHNIX KA06-50 (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)