Skip to main content
ENERGY STAR water heater model · PD 4576901

Arctic Arctic-HP-Hot Water-KA06-50 Water Heater Specifications (3.88 UEF)

Certified at 3.88 UEF across its 44.5-gallon nominal tank, 65 gal First Hour Rating, Arctic Arctic-HP-Hot Water-KA06-50 (Hybrid/Electric Heat Pump, Electric) places #165 of 706 out of 706 ENERGY STAR models (PD 4576901). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.58 / +68.7%. Rated annual electricity draw of 837 kWh/yr equates to roughly $152/yr ($1,520 over 10 years) at 18.16 cents/kWh. Closest certified alternative is PHNIX KA06-50 (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
65 gal
Storage Volume
44.5 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.58 / +68.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Arctic Arctic-HP-Hot Water-KA06-50 at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Arctic Arctic-HP-Hot Water-KA06-50: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Arctic Arctic-HP-Hot Water-KA06-50 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 3.88 UEF, Arctic Arctic-HP-Hot Water-KA06-50 places #165 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.18 UEF vs. 3.70 UEF median).

Arctic Arctic-HP-Hot Water-KA06-50 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.58 UEF (+68.7% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 837 kWh/yr for Arctic Arctic-HP-Hot Water-KA06-50 runs ~$152/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Arctic Arctic-HP-Hot Water-KA06-50: 10-year operating spend spans $1,225 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,949 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Arctic Arctic-HP-Hot Water-KA06-50 include PHNIX KA06-50 (3.88 UEF, at parity) alongside Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity).

How Complete Are the Certified Metrics for Arctic Arctic-HP-Hot Water-KA06-50?

Standing at #165 of 706 (top 30.6%) among 706 certified Hybrid/Electric Heat Pump heaters, Arctic Arctic-HP-Hot Water-KA06-50 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandArctic2 certified listingsENERGY STAR PD 4576901
Model NumberArctic-HP-Hot Water-KA06-50Draw pattern: Medium-UsageArctic-HP-Hot Water-KA06-50
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)65 gal-7 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use837 kWh/yr-235 kWh/yr vs. 1,072 kWh/yr medianEst. $152/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency412%-17.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)46.8" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 27 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-12Certified 2026-03-12Markets: United States, Canada

What Is the Projected Utility Bill for Arctic-HP-Hot Water-KA06-50 by State?

At 837 kWh/yr, Arctic Arctic-HP-Hot Water-KA06-50 averages about $152/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Estimated Annual Electricity Cost by State Rate (837 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$152.00/yrHawaii$395.00/yrCalifornia$249.00/yrTexas$133.00/yrWashington$122.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $152/yr $1,520 $4,890
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $395/yr $3,949 $12,706
California 29.75 ¢/kWh ($0.2975) $249/yr $2,490 $8,012
Texas 15.91 ¢/kWh ($0.1591) $133/yr $1,332 $4,285
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $122/yr $1,225 $3,940
Estimated electricity spend (837 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Arctic Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Arctic in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to Arctic-HP-Hot Water-KA06-50?

Ordered by minimal capacity and UEF spread relative to Arctic Arctic-HP-Hot Water-KA06-50, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
PHNIX KA06-50 Hybrid/Electric Heat Pump 44.5 gal 65 gal 3.88 (at parity) 837
Friedrich PROH50 T2 FD400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Richmond 10CE50-HP5S30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Friedrich PROH50 T2 FD400-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846

When Should Homeowners Skip Arctic Arctic-HP-Hot Water-KA06-50 (Hybrid/Electric Heat Pump)?

Check Arctic Arctic-HP-Hot Water-KA06-50's mechanical constraints—including utility space, Electric capacity, and Pass: +1.58 / +68.7% status—against typical residential installations.

Key Limitations & Exclusions

  • Arctic Arctic-HP-Hot Water-KA06-50 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Arctic Arctic-HP-Hot Water-KA06-50 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Arctic Arctic-HP-Hot Water-KA06-50 Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare PHNIX KA06-50 footprint.

Practical Specs & Code Questions for Arctic Arctic-HP-Hot Water-KA06-50

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Arctic Arctic-HP-Hot Water-KA06-50 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.88 UEF, Arctic Arctic-HP-Hot Water-KA06-50 shows Pass: +1.58 / +68.7% relative to May 6, 2029 federal DOE limits while placing #165 of 706 (top 30.6%) among 706 Hybrid/Electric Heat Pump peers like PHNIX KA06-50.

Will Arctic Arctic-HP-Hot Water-KA06-50 fit through a standard utility door and 72-inch basement ceiling?

Measuring 46.8 in. tall by 22 in. diameter, Arctic Arctic-HP-Hot Water-KA06-50 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Arctic Arctic-HP-Hot Water-KA06-50 during replacement?

Electrical specs for Arctic Arctic-HP-Hot Water-KA06-50 call for 240V at 27A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for Arctic Arctic-HP-Hot Water-KA06-50?

At 18.16 cents/kWh national residential pricing, Arctic Arctic-HP-Hot Water-KA06-50's 837 kWh/yr draw equals roughly $152 annually or $1,520 across a 10-year horizon (ranging from $122/yr in Washington hydro tiers up to $395/yr in Hawaii).

When is Arctic Arctic-HP-Hot Water-KA06-50 a poor fit for a residential replacement?

Avoid placing Arctic Arctic-HP-Hot Water-KA06-50 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does Arctic Arctic-HP-Hot Water-KA06-50 deliver?

With 65 gal FHR (-7 gal vs. 72 gal median), Arctic Arctic-HP-Hot Water-KA06-50 fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Arctic Arctic-HP-Hot Water-KA06-50?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Arctic; verify exact manufacturing week for Arctic Arctic-HP-Hot Water-KA06-50 using the Serial Number Lookup tool.

Does Arctic Arctic-HP-Hot Water-KA06-50 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Arctic Arctic-HP-Hot Water-KA06-50. Closest peer in Hybrid/Electric Heat Pump is PHNIX KA06-50 (3.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks