Richmond 10CE50-HP5S30 Water Heater Specifications (3.88 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Richmond 10CE50-HP5S30 achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating and ranks #165 of 706 in its 706-model cohort (PD 3387962), recording Pass: +1.58 / +68.7% under 2029 DOE rules. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
- Uniform Energy Factor
- 3.88 UEF
- Cohort UEF Rank
- #165 of 706 (top 30.6%)
- First Hour Rating
- 67 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.58 / +68.7%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Richmond 10CE50-HP5S30 logs 3.88 UEF and ranks #165 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Richmond 10CE50-HP5S30 holds a +1.58 UEF (+68.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Richmond 10CE50-HP5S30 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.
State electric sensitivity for Richmond 10CE50-HP5S30: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Richmond 10CE50-HP5S30 (3.88 UEF)? Check Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) and Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity).
Where Does Richmond 10CE50-HP5S30 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Richmond 10CE50-HP5S30 holds #165 of 706 (top 30.6%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Richmond | 80 certified listings | ENERGY STAR PD 3387962 |
| Model Number | 10CE50-HP5S30 | Draw pattern: Medium-Usage | 10CE50-HP5S30 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |
How Much Electricity Does 10CE50-HP5S30 Use in Different States?
Estimated at $154/yr nationally (846 kWh/yr), 10-year utility spending for Richmond 10CE50-HP5S30 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| California | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| Texas | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |
Does CPSC Flag Any Safety Notices on Richmond Units?
No open CPSC recall alerts appeared for Richmond as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to 10CE50-HP5S30?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Richmond 10CE50-HP5S30's gallon capacity and 3.88 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Friedrich PROH50 T2 FD400-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Rheem CPROPH50 T2 RH375-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Ruud CPROPH50 T2 CD375-30 | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| Bradford White RE2HP50**-1NCTT | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| Friedrich PROH50 T2 FD400-SO | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
When Should Homeowners Skip Richmond 10CE50-HP5S30 (Hybrid/Electric Heat Pump)?
Check Richmond 10CE50-HP5S30's mechanical constraints—including utility space, Electric capacity, and Pass: +1.58 / +68.7% status—against typical residential installations.
Key Limitations & Exclusions
- Richmond 10CE50-HP5S30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Richmond 10CE50-HP5S30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Richmond 10CE50-HP5S30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Richmond 10CE50-HP5S30 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 3.88 UEF, Richmond 10CE50-HP5S30 shows Pass: +1.58 / +68.7% relative to May 6, 2029 federal DOE limits while placing #165 of 706 (top 30.6%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH50 T2 FD400-30.
Will Richmond 10CE50-HP5S30 fit through a standard utility door and 72-inch basement ceiling?
Measuring 61.8 in. tall by 22.3 in. diameter, Richmond 10CE50-HP5S30 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Richmond 10CE50-HP5S30 during replacement?
Electrical specs for Richmond 10CE50-HP5S30 call for 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Richmond 10CE50-HP5S30?
At 18.16 cents/kWh national residential pricing, Richmond 10CE50-HP5S30's 846 kWh/yr draw equals roughly $154 annually or $1,540 across a 10-year horizon (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).
When is Richmond 10CE50-HP5S30 a poor fit for a residential replacement?
Avoid placing Richmond 10CE50-HP5S30 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Richmond 10CE50-HP5S30 deliver?
With 67 gal FHR (-5 gal vs. 72 gal median), Richmond 10CE50-HP5S30 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Richmond 10CE50-HP5S30?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 10CE50-HP5S30 using the Serial Number Lookup tool.
Does Richmond 10CE50-HP5S30 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 10CE50-HP5S30. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)