Skip to main content
ENERGY STAR water heater model · PD 3554262

Friedrich PROH50 T2 FD400-30 Water Heater Specifications (3.88 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Friedrich PROH50 T2 FD400-30 achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating and ranks #165 of 706 in its 706-model cohort (PD 3554262), recording Pass: +1.58 / +68.7% under 2029 DOE rules. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH50 T2 RH375-SO (3.88 UEF).

Uniform Energy Factor
3.88 UEF
Cohort UEF Rank
#165 of 706 (top 30.6%)
First Hour Rating
67 gal
Storage Volume
45 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.58 / +68.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Friedrich PROH50 T2 FD400-30 at 3.88 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Friedrich PROH50 T2 FD400-30: 3.88
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Friedrich PROH50 T2 FD400-30 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Friedrich PROH50 T2 FD400-30 logs 3.88 UEF and ranks #165 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Friedrich PROH50 T2 FD400-30 holds a +1.58 UEF (+68.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Friedrich PROH50 T2 FD400-30 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.

State electric sensitivity for Friedrich PROH50 T2 FD400-30: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Friedrich PROH50 T2 FD400-30 (3.88 UEF)? Check Rheem CPROPH50 T2 RH375-SO (3.88 UEF, at parity) and Richmond 10CE50-HP5S30 (3.88 UEF, at parity).

How Do Friedrich PROH50 T2 FD400-30 Specs Compare to Hybrid/Electric Heat Pump Medians?

Friedrich PROH50 T2 FD400-30 places #165 of 706 (top 30.6%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandFriedrich61 certified listingsENERGY STAR PD 3554262
Model NumberPROH50 T2 FD400-30Draw pattern: Medium-UsagePROH50 T2 FD400-30
Uniform Energy Factor (UEF)3.88+0.18 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)67 gal-5 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use846 kWh/yr-226 kWh/yr vs. 1,072 kWh/yr medianEst. $154/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)61.8" H x 22.3" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 21 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-10-15Certified 2026-10-15Markets: United States

What Does PROH50 T2 FD400-30 Cost to Operate Across State Electricity Rates?

At 846 kWh/yr, Friedrich PROH50 T2 FD400-30 runs roughly $154/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (846 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$154.00/yrHawaii$399.00/yrCalifornia$252.00/yrTexas$135.00/yrWashington$124.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $154/yr $1,536 $4,943
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $399/yr $3,991 $12,842
California 29.75 ¢/kWh ($0.2975) $252/yr $2,517 $8,098
Texas 15.91 ¢/kWh ($0.1591) $135/yr $1,346 $4,331
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $124/yr $1,238 $3,982
Estimated electricity spend (846 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Friedrich Water Heaters?

Zero active CPSC recalls matched Friedrich in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match PROH50 T2 FD400-30 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Friedrich PROH50 T2 FD400-30 by storage capacity and 3.88 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Rheem CPROPH50 T2 RH375-SO Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Richmond 10CE50-HP5S30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Ruud CPROPH50 T2 CD375-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846
Bradford White RE2HP50**-1NCTT Hybrid/Electric Heat Pump 45 gal 65 gal 3.89 (+0.01) 835
Rheem CPROPH50 T2 RH400-30 Hybrid/Electric Heat Pump 45 gal 67 gal 3.88 (at parity) 846

Who Is Friedrich PROH50 T2 FD400-30 Best For — and When Should You Pick Rheem CPROPH50 T2 RH375-SO?

Evaluate whether Friedrich PROH50 T2 FD400-30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Friedrich PROH50 T2 FD400-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Friedrich PROH50 T2 FD400-30 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Friedrich PROH50 T2 FD400-30 Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Rheem CPROPH50 T2 RH375-SO footprint.

What Are the Key Questions About Friedrich PROH50 T2 FD400-30?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Friedrich PROH50 T2 FD400-30 (3.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Friedrich PROH50 T2 FD400-30 records 3.88 UEF (Pass: +1.58 / +68.7%), placing #165 of 706 (top 30.6%) out of 706 certified Hybrid/Electric Heat Pump configurations.

Does Friedrich PROH50 T2 FD400-30 fit inside a tight hallway closet or low-headroom utility room?

Friedrich PROH50 T2 FD400-30 requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern Friedrich PROH50 T2 FD400-30?

For Friedrich PROH50 T2 FD400-30, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

What annual utility bill should homeowners budget for Friedrich PROH50 T2 FD400-30?

Using 846 kWh/yr, Friedrich PROH50 T2 FD400-30 generates an estimated $154/yr electric bill at 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii)—use the custom rate slider above for your utility tariff.

What are the main drawbacks of Friedrich PROH50 T2 FD400-30 (3.88 UEF)?

Friedrich PROH50 T2 FD400-30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Rheem CPROPH50 T2 RH375-SO.

What hot-water delivery rating governs Friedrich PROH50 T2 FD400-30?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Friedrich PROH50 T2 FD400-30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen Friedrich PROH50 T2 FD400-30 for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Friedrich; use our browser-only serial decoder to inspect Friedrich PROH50 T2 FD400-30's age and warranty window.

What alternative models sit closest to Friedrich PROH50 T2 FD400-30 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH50 T2 RH375-SO (3.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks