Arctic Arctic-HP-Hot Water-KA06-80 Water Heater Specifications (4.14 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Arctic Arctic-HP-Hot Water-KA06-80 achieves a certified 4.14 UEF rating across its 71-gallon nominal tank, 81 gal First Hour Rating and ranks #17 of 706 in its 706-model cohort (PD 4576902), recording Pass: +1.64 / +65.6% under 2029 DOE rules. Rated annual electricity draw of 1,199.7 kWh/yr equates to roughly $218/yr ($2,179 over 10 years) at 18.16 cents/kWh. Closest certified alternative is PHNIX KA06-80 (4.14 UEF).

Uniform Energy Factor
4.14 UEF
Cohort UEF Rank
#17 of 706 (top 2.5%)
First Hour Rating
81 gal
Storage Volume
71 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.64 / +65.6%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Arctic Arctic-HP-Hot Water-KA06-80 at 4.14 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Arctic Arctic-HP-Hot Water-KA06-80: 4.14
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Arctic Arctic-HP-Hot Water-KA06-80 relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Arctic Arctic-HP-Hot Water-KA06-80 logs 4.14 UEF and ranks #17 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Arctic Arctic-HP-Hot Water-KA06-80 holds a +1.64 UEF (+65.6%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,199.7 kWh/yr for Arctic Arctic-HP-Hot Water-KA06-80 runs ~$218/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for Arctic Arctic-HP-Hot Water-KA06-80: 10-year operating spend spans $1,755 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,660 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF)? Check PHNIX KA06-80 (4.14 UEF, at parity) and Noritz NHP-80-240 (4.24 UEF, delta +0.10).

How Do Arctic Arctic-HP-Hot Water-KA06-80 Specs Compare to Hybrid/Electric Heat Pump Medians?

Arctic Arctic-HP-Hot Water-KA06-80 places #17 of 706 (top 2.5%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandArctic2 certified listingsENERGY STAR PD 4576902
Model NumberArctic-HP-Hot Water-KA06-80Draw pattern: High-UsageArctic-HP-Hot Water-KA06-80
Uniform Energy Factor (UEF)4.14+0.44 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)81 gal+9 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,199.7 kWh/yr+128 kWh/yr vs. 1,072 kWh/yr medianEst. $218/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency458%+29.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)57.5" H x 25.1" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (25.1" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 27 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-12Certified 2026-03-12Markets: United States, Canada

What Does Arctic-HP-Hot Water-KA06-80 Cost to Operate Across State Electricity Rates?

At 1,199 kWh/yr, Arctic Arctic-HP-Hot Water-KA06-80 runs roughly $218/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,199.7 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$218.00/yrHawaii$566.00/yrCalifornia$357.00/yrTexas$191.00/yrWashington$176.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $218/yr $2,179 $7,626
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $566/yr $5,660 $19,812
California 29.75 ¢/kWh ($0.2975) $357/yr $3,569 $12,493
Texas 15.91 ¢/kWh ($0.1591) $191/yr $1,909 $6,681
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $176/yr $1,755 $6,144
Estimated electricity spend (1,199.7 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Arctic Water Heaters?

Zero active CPSC recalls matched Arctic in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match Arctic-HP-Hot Water-KA06-80 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Arctic Arctic-HP-Hot Water-KA06-80 by storage capacity and 4.14 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
PHNIX KA06-80 Hybrid/Electric Heat Pump 71 gal 81 gal 4.14 (at parity) 1,199.7
Noritz NHP-80-240 Hybrid/Electric Heat Pump 71 gal 82 gal 4.24 (+0.10) 1,148
LG APHWC802D Hybrid/Electric Heat Pump 72 gal 91 gal 4.1 (-0.04) 1,210
Friedrich PROH80 T2 FD400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (-0.07) 1,213
LG APHWC802L Hybrid/Electric Heat Pump 72 gal 91 gal 4.1 (-0.04) 1,210

What Installation Caveats Apply Before Buying Arctic Arctic-HP-Hot Water-KA06-80?

Even high-UEF units like Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Arctic Arctic-HP-Hot Water-KA06-80 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Arctic Arctic-HP-Hot Water-KA06-80 directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Arctic Arctic-HP-Hot Water-KA06-80 Strong Fit — 4.14 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare PHNIX KA06-80 footprint.

What Are the Key Questions About Arctic Arctic-HP-Hot Water-KA06-80?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Arctic Arctic-HP-Hot Water-KA06-80 eligible for continued manufacture past May 6, 2029?

At 4.14 UEF, Arctic Arctic-HP-Hot Water-KA06-80 achieves Pass: +1.64 / +65.6% for the 2029 DOE standard and stands #17 of 706 (top 2.5%) against PHNIX KA06-80 and Noritz NHP-80-240.

How tall and wide is Arctic Arctic-HP-Hot Water-KA06-80, and what service clearance is needed?

Physical dimensions for Arctic Arctic-HP-Hot Water-KA06-80 are 57.5 in. height and 25.1 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (25.1" d)); verify stair turns and drain pan width before delivery.

Will Arctic Arctic-HP-Hot Water-KA06-80 require upgrading household electrical panels or gas piping?

Arctic Arctic-HP-Hot Water-KA06-80 draws 240V at 27A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

Is Arctic Arctic-HP-Hot Water-KA06-80 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $218/yr ($2,180 over 10 years) to power Arctic Arctic-HP-Hot Water-KA06-80 at 1,199.7 kWh/yr under the 18.16 cents/kWh US average (ranging from $176/yr in Washington hydro tiers up to $566/yr in Hawaii).

Which installation bottlenecks limit Arctic Arctic-HP-Hot Water-KA06-80?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Arctic Arctic-HP-Hot Water-KA06-80 drops into resistance mode more often.

How does Arctic Arctic-HP-Hot Water-KA06-80 handle simultaneous showers and laundry?

Delivering 81 gal in the first hour (+9 gal vs. 72 gal median), Arctic Arctic-HP-Hot Water-KA06-80 combines 71 gal tank storage with rapid burner/element recovery.

How long is the warranty on Arctic Arctic-HP-Hot Water-KA06-80 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Arctic as of 2026-11-23. Confirm install proof and serial manufacture year on Arctic Arctic-HP-Hot Water-KA06-80 before calling service.

How do 2026 post-OBBBA rebates affect buying Arctic Arctic-HP-Hot Water-KA06-80?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is PHNIX KA06-80 (4.14 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks