Skip to main content
ENERGY STAR water heater model · PD 4573322

LG APHWC802L Water Heater Specifications (4.1 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, LG APHWC802L achieves a certified 4.1 UEF rating across its 72-gallon nominal tank, 91 gal First Hour Rating and ranks #20 of 706 in its 706-model cohort (PD 4573322), recording Pass: +1.60 / +64.0% under 2029 DOE rules. Rated annual electricity draw of 1,210 kWh/yr equates to roughly $220/yr ($2,197 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Uniform Energy Factor
4.1 UEF
Cohort UEF Rank
#20 of 706 (top 3.5%)
First Hour Rating
91 gal
Storage Volume
72 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.60 / +64.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking LG APHWC802L at 4.1 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50LG APHWC802L: 4.10
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC802L relative to the cohort median.
Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, LG APHWC802L logs 4.1 UEF and ranks #20 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), LG APHWC802L holds a +1.60 UEF (+64.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,210 kWh/yr for LG APHWC802L runs ~$220/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC802L: 10-year operating spend spans $1,770 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,709 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping LG APHWC802L (4.1 UEF)? Check Friedrich PROH80 T2 FD400-30 (4.07 UEF, delta -0.03) and Rheem CPROPH80 T2 RH375-SO (4.07 UEF, delta -0.03).

What Physical and Thermal Ratings Define LG APHWC802L?

Positioning at #20 of 706 (top 3.5%) out of 706 Hybrid/Electric Heat Pump peers, LG APHWC802L pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLG12 certified listingsENERGY STAR PD 4573322
Model NumberAPHWC802LDraw pattern: High-UsageAPHWC802L
Uniform Energy Factor (UEF)4.1+0.40 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)91 gal+19 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,210 kWh/yr+138 kWh/yr vs. 1,072 kWh/yr medianEst. $220/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency430%+1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)62.7" H x 19.7" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 24 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-134a (GWP:1430)Check regional AIM Act phase-down transitionEPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States

Why Do State Utility Rates Shift APHWC802L Running Costs?

Consuming 1,210 kWh annually puts LG APHWC802L near $220/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Estimated Annual Electricity Cost by State Rate (1,210 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$220.00/yrHawaii$571.00/yrCalifornia$360.00/yrTexas$193.00/yrWashington$177.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $220/yr $2,197 $7,595
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $571/yr $5,709 $19,731
California 29.75 ¢/kWh ($0.2975) $360/yr $3,600 $12,441
Texas 15.91 ¢/kWh ($0.1591) $193/yr $1,925 $6,654
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $177/yr $1,770 $6,118
Estimated electricity spend (1,210 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any LG Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for LG; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to LG APHWC802L?

Homeowners cross-shopping LG APHWC802L frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich PROH80 T2 FD400-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (-0.03) 1,213
Rheem CPROPH80 T2 RH375-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (-0.03) 1,213
Richmond 10CE80-HP5S30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (-0.03) 1,213
Ruud CPROPH80 T2 CD375-30 Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (-0.03) 1,213
Friedrich PROH80 T2 FD400-SO Hybrid/Electric Heat Pump 72 gal 87 gal 4.07 (-0.03) 1,213

When Should Homeowners Skip LG APHWC802L (Hybrid/Electric Heat Pump)?

Check LG APHWC802L's mechanical constraints—including utility space, Electric capacity, and Pass: +1.60 / +64.0% status—against typical residential installations.

Key Limitations & Exclusions

  • LG APHWC802L needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting LG APHWC802L directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing LG APHWC802L Strong Fit — 4.1 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

Sizing, Efficiency & Recall Answers for LG APHWC802L

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will LG APHWC802L stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.1 UEF, LG APHWC802L shows Pass: +1.60 / +64.0% relative to May 6, 2029 federal DOE limits while placing #20 of 706 (top 3.5%) among 706 Hybrid/Electric Heat Pump peers like Friedrich PROH80 T2 FD400-30.

Will LG APHWC802L fit through a standard utility door and 72-inch basement ceiling?

Measuring 62.7 in. tall by 19.7 in. diameter, LG APHWC802L notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support LG APHWC802L during replacement?

Electrical specs for LG APHWC802L call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for LG APHWC802L?

At 18.16 cents/kWh national residential pricing, LG APHWC802L's 1,210 kWh/yr draw equals roughly $220 annually or $2,200 across a 10-year horizon (ranging from $177/yr in Washington hydro tiers up to $571/yr in Hawaii).

When is LG APHWC802L a poor fit for a residential replacement?

Avoid placing LG APHWC802L directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does LG APHWC802L deliver?

With 91 gal FHR (+19 gal vs. 72 gal median), LG APHWC802L fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on LG APHWC802L?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for LG; verify exact manufacturing week for LG APHWC802L using the Serial Number Lookup tool.

Does LG APHWC802L qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for LG APHWC802L. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks