Noritz NHP-80-240 Water Heater Specifications (4.24 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Noritz NHP-80-240 (Electric) achieves a certified 4.24 UEF rating across its 71-gallon nominal tank, 82 gal First Hour Rating (rank #8 of 706, PD 4724094) and verifies as Pass: +1.74 / +69.6% for 2029 DOE floors. Rated annual electricity draw of 1,148 kWh/yr equates to roughly $208/yr ($2,085 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF).
- Uniform Energy Factor
- 4.24 UEF
- Cohort UEF Rank
- #8 of 706 (top 1.1%)
- First Hour Rating
- 82 gal
- Storage Volume
- 71 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.74 / +69.6%

Noritz NHP-80-240 records 4.24 UEF efficiency, putting it #8 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Noritz NHP-80-240 exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.74 UEF (+69.6%). At EIA August 2026 national rates (18.16 cents/kWh), 1,148 kWh/yr for Noritz NHP-80-240 runs ~$208/yr vs. ~$961/yr for a 0.92 UEF electric tank. Acoustic output is 48 dBA (quieter than 67.8% of Hybrid/Electric Heat Pump models).
State electric sensitivity for Noritz NHP-80-240: 10-year operating spend spans $1,680 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,416 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Noritz NHP-80-240 (4.24 UEF) are Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF, delta -0.10) and PHNIX KA06-80 (4.14 UEF, delta -0.10).
Which Specs Set Noritz NHP-80-240 Apart From Cohort Averages?
Ranked #8 of 706 (top 1.1%) inside the 706-model Hybrid/Electric Heat Pump cohort, Noritz NHP-80-240 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Noritz | 23 certified listings | ENERGY STAR PD 4724094 |
| Model Number | NHP-80-240 | Draw pattern: High-Usage | NHP-80-240 |
| Uniform Energy Factor (UEF) | 4.24 | +0.54 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,148 kWh/yr | +76 kWh/yr vs. 1,072 kWh/yr median | Est. $208/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 486% | +57.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 72" H x 25.2" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (25.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21.3 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 48 dBA | top 32.2% · quieter than 67.8% of Hybrid/Electric Heat Pump models · -1 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2026-10-30 | Certified 2026-10-30 | Markets: United States, Canada |
How Do Regional kWh Prices Impact NHP-80-240 Over 10 Years?
Using EIA Table 5.6.A benchmarks, Noritz NHP-80-240's 1,148 kWh/yr draw translates to roughly $208/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $208/yr | $2,085 | $7,524 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $542/yr | $5,416 | $19,547 |
| California | 29.75 ¢/kWh ($0.2975) | $342/yr | $3,415 | $12,325 |
| Texas | 15.91 ¢/kWh ($0.1591) | $183/yr | $1,826 | $6,592 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $168/yr | $1,680 | $6,061 |
What Should Noritz Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Noritz; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Arctic Arctic-HP-Hot Water-KA06-80 | Hybrid/Electric Heat Pump | 71 gal | 81 gal | 4.14 (-0.10) | 1,199.7 |
| PHNIX KA06-80 | Hybrid/Electric Heat Pump | 71 gal | 81 gal | 4.14 (-0.10) | 1,199.7 |
| LG APHWC802D | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (-0.14) | 1,210 |
| Friedrich PROH80 T2 FD400-30 | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (-0.17) | 1,213 |
| LG APHWC802L | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (-0.14) | 1,210 |
When Should Homeowners Skip Noritz NHP-80-240 (Hybrid/Electric Heat Pump)?
Check Noritz NHP-80-240's mechanical constraints—including utility space, Electric capacity, and Pass: +1.74 / +69.6% status—against typical residential installations.
Key Limitations & Exclusions
- Noritz NHP-80-240 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 48 dBA; avoid mounting Noritz NHP-80-240 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Noritz NHP-80-240
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Noritz NHP-80-240 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 4.24 UEF, Noritz NHP-80-240 shows Pass: +1.74 / +69.6% relative to May 6, 2029 federal DOE limits while placing #8 of 706 (top 1.1%) among 706 Hybrid/Electric Heat Pump peers like Arctic Arctic-HP-Hot Water-KA06-80.
Will Noritz NHP-80-240 fit through a standard utility door and 72-inch basement ceiling?
Measuring 72 in. tall by 25.2 in. diameter, Noritz NHP-80-240 notes: needs >72 in. overhead clearance; clears 28 in. utility doorway (25.2" d). Reserve space above the jacket for T&P piping and anode removal.
Do existing utility hookups support Noritz NHP-80-240 during replacement?
Electrical specs for Noritz NHP-80-240 call for 240V at 21.3A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.
What is the estimated 10-year operating spend for Noritz NHP-80-240?
At 18.16 cents/kWh national residential pricing, Noritz NHP-80-240's 1,148 kWh/yr draw equals roughly $208 annually or $2,080 across a 10-year horizon (ranging from $168/yr in Washington hydro tiers up to $542/yr in Hawaii).
When is Noritz NHP-80-240 a poor fit for a residential replacement?
Avoid placing Noritz NHP-80-240 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 48 dBA sound and cool exhaust airflow.
What First Hour Rating or flow capacity does Noritz NHP-80-240 deliver?
With 82 gal FHR (+10 gal vs. 72 gal median), Noritz NHP-80-240 fits larger 3–5 person homes cleanly.
How do you verify manufacturing age and recall status on Noritz NHP-80-240?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Noritz; verify exact manufacturing week for Noritz NHP-80-240 using the Serial Number Lookup tool.
Does Noritz NHP-80-240 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Noritz NHP-80-240. Closest peer in Hybrid/Electric Heat Pump is Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)