Ariston ARIHPWH-80-T Water Heater Specifications (4.1 UEF)
The Ariston ARIHPWH-80-T (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.1 UEF rating across its 74-gallon nominal tank, 88 gal First Hour Rating, ranking #20 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4437415). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.60 / +64.0%. Rated annual electricity draw of 1,210 kWh/yr equates to roughly $220/yr ($2,197 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Lennox WHHP080T45MD240S**** (4.1 UEF).
- Uniform Energy Factor
- 4.1 UEF
- Cohort UEF Rank
- #20 of 706 (top 3.5%)
- First Hour Rating
- 88 gal
- Storage Volume
- 74 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.60 / +64.0%

Ariston ARIHPWH-80-T (4.1 UEF) ranks #20 of 706 Hybrid/Electric Heat Pump models — 6-way tie; top 3.5%, more efficient than 96.5% of Hybrid/Electric Heat Pump models, +0.40 UEF above the 3.70 UEF median.
Federal 2029 margin for Ariston ARIHPWH-80-T: +1.60 UEF (+64.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,210 kWh/yr for Ariston ARIHPWH-80-T runs ~$220/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ariston ARIHPWH-80-T: 10-year operating spend spans $1,770 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,709 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Peer comparison: Ariston ARIHPWH-80-T (4.1 UEF) compares closely with Lennox WHHP080T45MD240S**** (4.1 UEF, at parity) and Eco-Logical OMNI-80HP2-1A (4.11 UEF, delta +0.01).
Which Specs Set Ariston ARIHPWH-80-T Apart From Cohort Averages?
Ranked #20 of 706 (top 3.5%) inside the 706-model Hybrid/Electric Heat Pump cohort, Ariston ARIHPWH-80-T is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ariston | 8 certified listings | ENERGY STAR PD 4437415 |
| Model Number | ARIHPWH-80-T | Draw pattern: High-Usage | ARIHPWH-80-T |
| Uniform Energy Factor (UEF) | 4.1 | +0.40 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 88 gal | +16 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,210 kWh/yr | +138 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 474% | +45.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59.8" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
How Do Regional kWh Prices Impact ARIHPWH-80-T Over 10 Years?
Using EIA Table 5.6.A benchmarks, Ariston ARIHPWH-80-T's 1,210 kWh/yr draw translates to roughly $220/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,197 | $7,595 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $571/yr | $5,709 | $19,731 |
| California | 29.75 ¢/kWh ($0.2975) | $360/yr | $3,600 | $12,441 |
| Texas | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,925 | $6,654 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,770 | $6,118 |
What Should Ariston Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Ariston; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Lennox WHHP080T45MD240S**** | Hybrid/Electric Heat Pump | 74 gal | 88 gal | 4.1 (at parity) | 1,210 |
| Eco-Logical OMNI-80HP2-1A | Hybrid/Electric Heat Pump | 74 gal | 82 gal | 4.11 (+0.01) | 1,206 |
| Navien NWP500S080AUMB | Hybrid/Electric Heat Pump | 74 gal | 85 gal | 4.05 (-0.05) | 1,265 |
| 1HVAC ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (-0.10) | 1,240 |
| ACIQ ACIQ-80G-HP-WH | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (-0.10) | 1,240 |
What Installation Caveats Apply Before Buying Ariston ARIHPWH-80-T?
Even high-UEF units like Ariston ARIHPWH-80-T (4.1 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Ariston ARIHPWH-80-T needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-80-T directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Ariston ARIHPWH-80-T
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Ariston ARIHPWH-80-T eligible for continued manufacture past May 6, 2029?
At 4.1 UEF, Ariston ARIHPWH-80-T achieves Pass: +1.60 / +64.0% for the 2029 DOE standard and stands #20 of 706 (top 3.5%) against Lennox WHHP080T45MD240S**** and Eco-Logical OMNI-80HP2-1A.
How tall and wide is Ariston ARIHPWH-80-T, and what service clearance is needed?
Physical dimensions for Ariston ARIHPWH-80-T are 59.8 in. height and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)); verify stair turns and drain pan width before delivery.
Will Ariston ARIHPWH-80-T require upgrading household electrical panels or gas piping?
Ariston ARIHPWH-80-T draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.
Is Ariston ARIHPWH-80-T economical to operate at 18.16 cents/kWh US electric rates?
Expect roughly $220/yr ($2,200 over 10 years) to power Ariston ARIHPWH-80-T at 1,210 kWh/yr under the 18.16 cents/kWh US average (ranging from $177/yr in Washington hydro tiers up to $571/yr in Hawaii).
Which installation bottlenecks limit Ariston ARIHPWH-80-T?
If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Ariston ARIHPWH-80-T drops into resistance mode more often.
How does Ariston ARIHPWH-80-T handle simultaneous showers and laundry?
Delivering 88 gal in the first hour (+16 gal vs. 72 gal median), Ariston ARIHPWH-80-T combines 74 gal tank storage with rapid burner/element recovery.
How long is the warranty on Ariston ARIHPWH-80-T and how do you decode its serial?
CPSC records show 0 active plumbing recalls for Ariston as of 2026-11-23. Confirm install proof and serial manufacture year on Ariston ARIHPWH-80-T before calling service.
How do 2026 post-OBBBA rebates affect buying Ariston ARIHPWH-80-T?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Lennox WHHP080T45MD240S**** (4.1 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)