Skip to main content
ENERGY STAR water heater model · PD 4470523

Eco-Logical OMNI-80HP2-1A Water Heater Specifications (4.11 UEF)

With PD 4470523 certification, Eco-Logical OMNI-80HP2-1A (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.11 UEF rating across its 74-gallon nominal tank, 82 gal First Hour Rating, standing #19 of 706 across 706 peers with Pass: +1.61 / +64.4% for May 6, 2029. Rated annual electricity draw of 1,206 kWh/yr equates to roughly $219/yr ($2,190 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-80-T (4.1 UEF).

Uniform Energy Factor
4.11 UEF
Cohort UEF Rank
#19 of 706 (top 2.7%)
First Hour Rating
82 gal
Storage Volume
74 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.61 / +64.4%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Eco-Logical OMNI-80HP2-1A at 4.11 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50Eco-Logical OMNI-80HP2-1A: 4.11
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Eco-Logical OMNI-80HP2-1A relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Eco-Logical OMNI-80HP2-1A at 4.11 UEF (#19 of 706; +0.41 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Eco-Logical OMNI-80HP2-1A stands +1.61 UEF (+64.4%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,206 kWh/yr for Eco-Logical OMNI-80HP2-1A runs ~$219/yr vs. ~$978/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Eco-Logical OMNI-80HP2-1A: 10-year operating spend spans $1,764 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,690 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Ariston ARIHPWH-80-T (4.1 UEF, delta -0.01) and Lennox WHHP080T45MD240S**** (4.1 UEF, delta -0.01) bracket Eco-Logical OMNI-80HP2-1A.

How Do Eco-Logical OMNI-80HP2-1A Specs Compare to Hybrid/Electric Heat Pump Medians?

Eco-Logical OMNI-80HP2-1A places #19 of 706 (top 2.7%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandEco-Logical6 certified listingsENERGY STAR PD 4470523
Model NumberOMNI-80HP2-1ADraw pattern: High-UsageOMNI-80HP2-1A
Uniform Energy Factor (UEF)4.11+0.41 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,206 kWh/yr+134 kWh/yr vs. 1,072 kWh/yr medianEst. $219/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency424%-5.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)73.4" H x 18.5" DNeeds >72 in. overhead clearance; clears 28 in. utility doorway (18.5" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 19.8 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-513A (GWP:630)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Sound Pressure Level49 dBAquieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA medianIndoor placement check
Certification Date2025-07-04Certified 2025-07-04Markets: United States, Canada

What Does OMNI-80HP2-1A Cost to Operate Across State Electricity Rates?

At 1,206 kWh/yr, Eco-Logical OMNI-80HP2-1A runs roughly $219/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Estimated Annual Electricity Cost by State Rate (1,206 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$219.00/yrHawaii$569.00/yrCalifornia$359.00/yrTexas$192.00/yrWashington$176.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $219/yr $2,190 $7,595
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $569/yr $5,690 $19,731
California 29.75 ¢/kWh ($0.2975) $359/yr $3,588 $12,441
Texas 15.91 ¢/kWh ($0.1591) $192/yr $1,919 $6,654
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $176/yr $1,764 $6,118
Estimated electricity spend (1,206 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Eco-Logical Water Heaters?

Zero active CPSC recalls matched Eco-Logical in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match OMNI-80HP2-1A Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Eco-Logical OMNI-80HP2-1A by storage capacity and 4.11 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Ariston ARIHPWH-80-T Hybrid/Electric Heat Pump 74 gal 88 gal 4.1 (-0.01) 1,210
Lennox WHHP080T45MD240S**** Hybrid/Electric Heat Pump 74 gal 88 gal 4.1 (-0.01) 1,210
Navien NWP500S080AUMB Hybrid/Electric Heat Pump 74 gal 85 gal 4.05 (-0.06) 1,265
1HVAC ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (-0.11) 1,240
ACIQ ACIQ-80G-HP-WH Hybrid/Electric Heat Pump 74 gal 91 gal 4.0 (-0.11) 1,240

Which Home Setups Are NOT a Fit for Eco-Logical OMNI-80HP2-1A?

Comparing Eco-Logical OMNI-80HP2-1A against Ariston ARIHPWH-80-T requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Eco-Logical OMNI-80HP2-1A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Eco-Logical OMNI-80HP2-1A directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Eco-Logical OMNI-80HP2-1A Strong Fit — 4.11 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare Ariston ARIHPWH-80-T footprint.

What Are the Key Questions About Eco-Logical OMNI-80HP2-1A?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Eco-Logical OMNI-80HP2-1A score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Eco-Logical OMNI-80HP2-1A logs 4.11 UEF (Pass: +1.61 / +64.4%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Eco-Logical OMNI-80HP2-1A?

With a 73.4 in. height and 18.5 in. diameter, Eco-Logical OMNI-80HP2-1A fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (18.5" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Eco-Logical OMNI-80HP2-1A?

Powered via 240V at 19.8A max, Eco-Logical OMNI-80HP2-1A requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Eco-Logical OMNI-80HP2-1A?

Annual electric spend for Eco-Logical OMNI-80HP2-1A (1,206 kWh/yr) averages $219/yr nationwide (ranging from $176/yr in Washington hydro tiers up to $569/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Eco-Logical OMNI-80HP2-1A?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Eco-Logical OMNI-80HP2-1A.

Is Eco-Logical OMNI-80HP2-1A sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Eco-Logical OMNI-80HP2-1A at 82 gal First Hour Rating (+10 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Eco-Logical have active CPSC SaferProducts notices affecting OMNI-80HP2-1A?

Zero CPSC recall alerts matched Eco-Logical (2026-11-23 check). Keep your Eco-Logical OMNI-80HP2-1A serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Eco-Logical OMNI-80HP2-1A (4.11 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Eco-Logical OMNI-80HP2-1A. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-80-T (4.1 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks