Bradford White RE2H50S*-***** Water Heater Specifications (3.44 UEF)
Engineered as a Electric Hybrid/Electric Heat Pump unit, Bradford White RE2H50S*-***** achieves a certified 3.44 UEF rating across its 45-gallon nominal tank, 65 gal First Hour Rating and ranks #622 of 706 in its 706-model cohort (PD 2408472), recording Pass: +1.14 / +49.6% under 2029 DOE rules. Rated annual electricity draw of 944 kWh/yr equates to roughly $171/yr ($1,714 over 10 years) at 18.16 cents/kWh. Closest certified alternative is JETGLAS RE2H50S*-***** (3.44 UEF).
- Uniform Energy Factor
- 3.44 UEF
- Cohort UEF Rank
- #622 of 706
- First Hour Rating
- 65 gal
- Storage Volume
- 45 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.14 / +49.6%

Within the 706-unit Hybrid/Electric Heat Pump cohort, Bradford White RE2H50S*-***** logs 3.44 UEF and ranks #622 of 706.
Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), Bradford White RE2H50S*-***** holds a +1.14 UEF (+49.6%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 944 kWh/yr for Bradford White RE2H50S*-***** runs ~$171/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for Bradford White RE2H50S*-*****: 10-year operating spend spans $1,381 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,454 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Cross-shopping Bradford White RE2H50S*-***** (3.44 UEF)? Check JETGLAS RE2H50S*-***** (3.44 UEF, at parity) and Friedrich PROH50 T2 FD310BM (3.5 UEF, delta +0.06).
Where Does Bradford White RE2H50S*-***** Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Bradford White RE2H50S*-***** holds #622 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Bradford White | 19 certified listings | ENERGY STAR PD 2408472 |
| Model Number | RE2H50S*-***** | Draw pattern: Medium-Usage | RE2H50S*-***** |
| Uniform Energy Factor (UEF) | 3.44 | -0.26 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 944 kWh/yr | -128 kWh/yr vs. 1,072 kWh/yr median | Est. $171/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 406% | -23.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.3" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 19 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
How Much Electricity Does RE2H50S*-***** Use in Different States?
Estimated at $171/yr nationally (944 kWh/yr), 10-year utility spending for Bradford White RE2H50S*-***** shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $171/yr | $1,714 | $4,696 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $445/yr | $4,454 | $12,201 |
| California | 29.75 ¢/kWh ($0.2975) | $281/yr | $2,808 | $7,693 |
| Texas | 15.91 ¢/kWh ($0.1591) | $150/yr | $1,502 | $4,114 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $138/yr | $1,381 | $3,783 |
Does CPSC Flag Any Safety Notices on Bradford White Units?
Checking 2026-11-23 SaferProducts data shows 2 notices mentioning Bradford White; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
- Recall #02553 (2002-08-15): CPSC, Bradford White Corporation, Announce Recall of Gas Water Heater (CPSC Notice)
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to RE2H50S*-*****?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Bradford White RE2H50S*-*****'s gallon capacity and 3.44 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| JETGLAS RE2H50S*-***** | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.44 (at parity) | 944 |
| Friedrich PROH50 T2 FD310BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (+0.06) | 915 |
| Rheem CPROPH50 T2 RH350BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (+0.06) | 915 |
| Ruud PRO H50 T2 RU310BM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (+0.06) | 915 |
| Friedrich PROH50 T2 FD310UM | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (+0.06) | 915 |
Which Home Setups Are NOT a Fit for Bradford White RE2H50S*-*****?
Comparing Bradford White RE2H50S*-***** against JETGLAS RE2H50S*-***** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.
Key Limitations & Exclusions
- Bradford White RE2H50S*-***** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Bradford White RE2H50S*-***** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Bradford White RE2H50S*-*****
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Bradford White RE2H50S*-***** score under 10 CFR 430.32 May 2029 water heater minimums?
Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Bradford White RE2H50S*-***** logs 3.44 UEF (Pass: +1.14 / +49.6%) within the 706-unit Hybrid/Electric Heat Pump group.
What physical clearance dimensions apply when installing Bradford White RE2H50S*-*****?
With a 45.3 in. height and 18 in. diameter, Bradford White RE2H50S*-***** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d), plus 6–12 in. above for plumbing shutoffs.
What 240V circuit or IFGC fuel line capacity fits Bradford White RE2H50S*-*****?
Powered via 240V at 19A max, Bradford White RE2H50S*-***** requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.
How do state electricity prices change annual costs for Bradford White RE2H50S*-*****?
Annual electric spend for Bradford White RE2H50S*-***** (944 kWh/yr) averages $171/yr nationwide (ranging from $138/yr in Washington hydro tiers up to $445/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.
What homeowner setups should avoid choosing Bradford White RE2H50S*-*****?
Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Bradford White RE2H50S*-*****.
Is Bradford White RE2H50S*-***** sized adequately for a 2-to-4-person household?
ENERGY STAR certifies Bradford White RE2H50S*-***** at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.
Does Bradford White have active CPSC SaferProducts notices affecting RE2H50S*-*****?
CPSC SaferProducts records show 2 brand-level recall notices mentioning Bradford White as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Which competing water heater matches Bradford White RE2H50S*-***** (3.44 UEF) most closely?
State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Bradford White RE2H50S*-*****. Closest peer in Hybrid/Electric Heat Pump is JETGLAS RE2H50S*-***** (3.44 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)